ASTM E273-2010 2500 Standard Practice for Ultrasonic Testing of the Weld Zone of Welded Pipe and Tubing《对焊接管件的焊缝区进行超声波检测的标准实施规程》.pdf
《ASTM E273-2010 2500 Standard Practice for Ultrasonic Testing of the Weld Zone of Welded Pipe and Tubing《对焊接管件的焊缝区进行超声波检测的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E273-2010 2500 Standard Practice for Ultrasonic Testing of the Weld Zone of Welded Pipe and Tubing《对焊接管件的焊缝区进行超声波检测的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E273 10Standard Practice forUltrasonic Testing of the Weld Zone of Welded Pipe andTubing1This standard is issued under the fixed designation E273; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice2describes general ultrasonic testi
3、ng pro-cedures for the detection of discontinuities in the weld andadjacent heat affected zones of welded pipe and tubing byscanning with relative motion between the search unit and pipeor tube. When contact or unfocused immersion search units areemployed, this practice is intended for tubular produ
4、cts havingspecified outside diameters $2 in. ($50 mm) and specifiedwall thicknesses of18 to 1116 in. (3 to 27 mm). When properlyfocused immersion search units are employed, this practicemay also be applied to material of smaller diameter and thinnerwall.NOTE 1When contact or unfocused immersion sear
5、ch units are used,precautions should be exercised when examining pipes or tubes near thelower specified limits. Certain combinations of search unit size, frequency,thinwall thicknesses, and small diameters could cause generation ofunwanted sound waves that may produce erroneous examination results.1
6、.2 All surfaces of material to be examined in accordancewith this practice shall be clean from scale, dirt, burrs, slag,spatter or other conditions that would interfere with theexamination results. The configuration of the weld must besuch that interfering signals are not generated by reflectionsfro
7、m it. Treatment of the inner surface and outer surface weldbeads such as trimming (“scarfing”) or rolling is often requiredto remove protuberances that could result in spurious reflec-tions.1.3 This practice does not establish acceptance criteria, theymust be specified by the using parties.1.4 The v
8、alues stated in inch-pound units are to be regardedas the standard. The SI equivalents are in parentheses and maybe approximate.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish
9、appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E543 Specification for Agencies Performing Nondestruc-tive TestingE1316 Terminology for Nondestructive Examinations2.2 ASNT DocumentsRecommended
10、 Practice SNT-TC-1A Personnel Qualifica-tion and Certification in Nondestructive Testing3. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, see Terminology E1316.4. Summary of Practice4.1 A pulsed ultrasonic angle beam shall be propagated inthe wall of the pipe or tube by e
11、ither the surface contact orimmersion method. Fig. 1 illustrates the characteristic obliquesound entry into the pipe wall for both contact and immersionexamination from one search unit.NOTE 2The immersion examination method may include tanks,wheel search units, or bubbler systems.4.2 The weld line s
12、hall be examined from both sides toensure detection of imperfections with a shape or orientationthat produces a preferential direction of reflection.5. Apparatus5.1 The instruments and accessory equipment shall becapable of producing, receiving, amplifying, and displayingelectrical pulses at frequen
13、cies and pulse rates deemed neces-sary by the using parties. They shall be capable of distinguish-ing the reference reflectors described in Section 8 to the extentrequired in the standardization procedure outlined in Section 9.1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-s
14、tructive Testing and is the direct responsibility of Subcommittee E07.06 onUltrasonic Method.Current edition approved June 1, 2010. Published July 2010. Originally approvedin 1965. Last previous edition approved in 2005 as E273 - 01(2005). DOI:10.1520/E0273-10.2For ASME Boiler and Pressure Vessel Co
15、de applications see related PracticeSE-273 in Section II of that Code.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
16、 website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 For pulse echo examination systems, the contact orimmersion search units should produce ultrasonic waves thattravel in the pipe or tube wall at a refracted angle of from 35
17、to 70 and perpendicular to the weld seam. For pitch/catch orthrough transmission examination systems, orientation of theentry sound beam other than perpendicular to the weld seammay be required.5.3 CouplantA liquid such as water, oil, glycerin, etc.,capable of conducting ultrasonic vibrations from t
18、he searchunit to the pipe or tube shall be used. Rust inhibitors, softeners,and wetting agents may be added to the couplant. The couplantliquid with all additives should not be detrimental to thesurface condition of the pipe or tubing and should wet thesurface. In examining electric-resistance-welde
19、d pipe, water-soluble oil used in cooling the pipe serves as a satisfactorycouplant.5.4 Distance Amplitude CompensationThe use of elec-tronic methods to compensate for attenuation losses as afunction of ultrasonic metal travel distance may be employed.5.5 Search UnitsThe search unit must be appropri
20、atelysized with respect to width and beam included angle to achievefull wall thickness coverage (2). Where this can not beachieved with a single search unit propagating in a givendirection, two or more search units may be used to scan in eachdirection. The effective beam length of the search units s
21、hall besuch that reliable detection of all reference reflectors isaccomplished without exceeding the “noise” limits of 9.2. Thefocal length of focused search units shall be at least equal to theradius of the material plus a suitable water path so that initialfocus may be on the tube or pipe central
22、axis (1).6. Basis of Application6.1 The following are items that require decision for use ofthis practice:6.1.1 Acceptance criteria,6.1.2 Type, dimension, and number of reference reflectors tobe placed in the reference standard,6.1.3 Standardization of examination sensitivity intervals,6.1.4 Operato
23、r qualifications,6.1.5 Qualification of NDT agency (as defined in PracticeE543), if required. Practice E543 may be used for this agencyqualification.6.1.6 Examination frequency,6.1.7 Pulse repetition rate,6.1.8 Sound beam orientation and number of beams used,6.1.9 Procedure and use of distance ampli
24、tude compensa-tion, and6.1.10 Reporting of examination results.7. Personnel Qualification7.1 Personnel performing the ultrasonic examination shallbe qualified and certified in accordance with ASNT Recom-mended Practice SNT-TC-1A or an equivalent document, toestablish their ability to conduct ultraso
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME27320102500STANDARDPRACTICEFORULTRASONICTESTINGOFTHEWELDZONEOFWELDEDPIPEANDTUBING 焊接 焊缝 进行 超声波 检测

链接地址:http://www.mydoc123.com/p-527274.html