ASTM E235 E235M-2012 red 6806 Standard Specification for Type K and Type N Mineral-Insulated Metal-Sheathed Thermocouples for Nuclear or for Other High-Reliability Applications《核设施.pdf
《ASTM E235 E235M-2012 red 6806 Standard Specification for Type K and Type N Mineral-Insulated Metal-Sheathed Thermocouples for Nuclear or for Other High-Reliability Applications《核设施.pdf》由会员分享,可在线阅读,更多相关《ASTM E235 E235M-2012 red 6806 Standard Specification for Type K and Type N Mineral-Insulated Metal-Sheathed Thermocouples for Nuclear or for Other High-Reliability Applications《核设施.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:E23506 Designation: E235/E235M 12Standard Specification forThermocouples, Sheathed, Type K and Type N Mineral-Insulated, Metal-Sheathed Thermocouples for Nuclear or forOther High-Reliability Applications1This standard is issued under the fixed designation E235/E235M; the number immediate
2、ly following the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This spec
3、ification covers the requirements for simplex, compacted mineral-insulated, metal-sheathed (MIMS), Type K andN thermocouples for nuclear or other high reliability service. Depending on size, these thermocouples are normally suitable foroperating temperatures to 1652 F (900 C); 1652F 900C; special co
4、nditions of environment and life expectancy may permittheir use at temperatures in excess of 2012 F (1100 C). 2012F 1100C. This specification was prepared specifically to detailrequirements for using this type of sheathedMIMS thermocouple for use in nuclear environments. This specificationenvironmen
5、ts,but they can also be used for sheathed thermocouples which are required for laboratory or general commercial applications wherethe environmental conditions exceed normal service requirements. The intended use of a sheathedMIMS thermocouple in a specificnuclear application will require evaluation
6、by the purchaser of the compatibility of the thermocouple, including the effect of thetemperature, atmosphere, and integrated neutron flux on the materials and accuracy of the thermoelements in the proposedapplication by the purchaser.1.2 This specification does not attempt to include all possible s
7、pecifications, standards, etc., for materials that may be used assheathing, insulation, and thermocouple wires for sheathed-type construction. The requirements of this specification include onlythe austenitic stainless steels and other alloys as allowed withby Specification E585/E585M for sheathing,
8、 magnesium oxide oraluminum oxide as insulation, and Type K and N thermocouple wires for thermoelements (see Note 1).1.21.3 General DesignNominal sizes of the finished thermocouples shall be 0.0400 in. (1.016 mm), 0.0625 in. (1.588 mm), 0.125in. (3.175 mm), 0.1875 in. (4.763 mm), or 0.250 in. (6.350
9、 mm). Sheath dimensions and tolerances for each nominal size shallbe in accordance with Nominal sizes of the finished thermocouples shall be 0.0400 in., 0.0625 in., 0.125 in., 0.1875 in., or 0.250in. 1.000 mm, 1.500 mm, 3.000 mm, 4.500 mm, or 6.000 mm. Sheath dimensions and tolerances for each nomin
10、al size shall bein accordance with Table 1 and Figs. 1 and 2. The measuring junction styles for thermocouples covered by this specification areas follows:1.2.11.3.1 Style G2(grounded)Measuring junction electrically connected to conductive sheaths, and1.2.2The measuring junction is electrically conne
11、cted to its conductive sheath, and1.3.2 Style U2(ungrounded)Measuring junctions are electrically isolated from conductive sheaths and from reference ground.1.3The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for informationonly.1.4The meas
12、uring junction is electrically isolated from its conductive sheath and from reference ground.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem are not exact equivalents or conversions; therefore, each system shall
13、be used independently of the other. Combining valuesfrom the two systems may result in non-conformance with the standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish approp
14、riate safety and health practices and determine the applicability of regulatorylimitations prior to use.1This specification is under the jurisdiction of ASTM Committee E20 on Temperature Measurement and is the direct responsibility of Subcommittee E20.04 onThermocouples.Current edition approved Nov.
15、May 1, 2006.2012. Published November 2006.August 2012. Originally approved in 1964. Last previous edition approved in 20032006 asE235 036. DOI: 10.1520/E0235-06.10.1520/E0235-12.2Style G and Style U measuring junctions were previously termed Class 1 and Class 2 measuring junctions respectively.1This
16、 document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior edition
17、s as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2. Referenced Documents2.1 ASTM Standards:3A262 Prac
18、tices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless SteelsE3 Guide for Preparation of Metallographic SpecimensE45 Test Methods for Determining the Inclusion Content of Steel E94Guide for Radiographic ExaminationE112 Test Methods for Determining Average Grain SizeE165 P
19、ractice for Liquid Penetrant Examination for General IndustryE220 Test Method for Calibration of Thermocouples By Comparison TechniquesE230 Specification and Temperature-Electromotive Force (EMF) Tables for Standardized ThermocouplesE344 Terminology Relating to Thermometry and HydrometryE585/E585M S
20、pecification for Compacted Mineral-Insulated, Metal-Sheathed, Base Metal Thermocouple CableE780 Test Method for Measuring the Insulation Resistance of Mineral-Insulated, Metal-Sheathed Thermocouples andThermocouple Cable at Room TemperatureE839 Test Methods for Sheathed Thermocouples and Sheathed Th
21、ermocouple CableE883 Guide for ReflectedLight PhotomicrographyE1652 Specification for Magnesium Oxide and Aluminum Oxide Powder and Crushable Insulators Used in the Manufacture ofMetal-Sheathed Platinum Resistance Thermometers, Base Metal Thermocouples, and Noble Metal Thermocouples2.2 ANSI Standard
22、:B46.1 Surface Texture42.3 American Welding Society Standard:A5.9 Specification for Corrosion-Resisting Chromium and Chromium-Nickel Steel-Welding Rods and Bare Electrodes53. Terminology3.1 The definitions given in Terminology E344 shall apply to this specification.3.2 Definitions of Terms Specific
23、to This Standard:3.2.1 lot, na quantity of finished MIMS thermocouples manufactured from the same lot of MIMS cable, then assembled andprocessed at the same time under the same controlled production conditions to their required final configuration.4. Ordering Information and Basis of Purchase4.1 The
24、 purchase order documents shall specify the following information:4.1.1 The quantity, length, and nominal diameter of the sheathedMIMS thermocouple,3For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Stand
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME235E235M2012RED6806STANDARDSPECIFICATIONFORTYPEKANDTYPENMINERALINSULATEDMETALSHEATHEDTHERMOCOUPLESFORNUCLEARORFOROTHERHIGHRELIABILITYAPPLICATIONS

链接地址:http://www.mydoc123.com/p-527183.html