ASTM E230 E230M-2012 red 6793 Standard Specification and Temperature-Electromotive Force (emf) Tables for Standardized Thermocouples《标准化热电偶用标准规范和温度电动势 (emf) 图表》.pdf
《ASTM E230 E230M-2012 red 6793 Standard Specification and Temperature-Electromotive Force (emf) Tables for Standardized Thermocouples《标准化热电偶用标准规范和温度电动势 (emf) 图表》.pdf》由会员分享,可在线阅读,更多相关《ASTM E230 E230M-2012 red 6793 Standard Specification and Temperature-Electromotive Force (emf) Tables for Standardized Thermocouples《标准化热电偶用标准规范和温度电动势 (emf) 图表》.pdf(169页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E230/E230M 111 E230/E230M 12 An American National StandardStandard Specification andTemperature-Electromotive Force (emf) Tables forStandardized Thermocouples1This standard is issued under the fixed designation E230/E230M; the number immediately following the designation indicates the y
2、earof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTETable 46 was changed editorially in October 2011.1. Scope1.
3、1 This specification contains reference tables (Tables 8 to 25) that give temperature-electromotive force (emf) relationshipsfor Types B, E, J, K, N, R, S, T, and C thermocouples.2 These are the thermocouple types most commonly used in industry. Thetables contain all of the temperature-emf data curr
4、ently available for the thermocouple types covered by this standard and mayinclude data outside of the recommended upper temperature limit of an included thermocouple type.1.2 In addition, the specification includes standard and special tolerances on initial values of emf versus temperature fortherm
5、ocouples (Table 1), thermocouple extension wires (Table 2), and compensating extension wires for thermocouples (Table 3).Users should note that the stated tolerances apply only to the temperature ranges specified for the thermocouple types as given inTables 1, 2, and 3, and do not apply to the tempe
6、rature ranges covered in Tables 8 to 25.1.3 Tables 4 and 5 provide insulation color coding for thermocouple and thermocouple extension wires as customarily used inthe United States.1.4 Recommendations regarding upper temperature limits for the thermocouple types referred to in 1.1 are provided in Ta
7、ble 6.1.5 Tables 26 to 45 give temperature-emf data for single-leg thermoelements referenced to platinum (NIST Pt-67). The tablesinclude values for Types BP, BN, JP, JN, KP (same as EP), KN, NP, NN, TP, and TN (same as EN).1.6 Tables for Types RP, RN, SP, and SN thermoelements are not included since
8、, nominally, Tables 18 to 21 represent thethermoelectric properties of Type RP and SP thermoelements referenced to pure platinum. Tables for the individual thermoelementsof Type C are not included because materials for Type C thermocouples are normally supplied as matched pairs only.1.7 Polynomial c
9、oefficients which may be used for computation of thermocouple emf as a function of temperature are given inTable 7. Coefficients for the emf of each thermocouple pair as well as for the emf of most individual thermoelements versusplatinum are included. Coefficients for type RP and SP thermoelements
10、are not included since they are nominally the same as fortypes R and S thermocouples, and coefficients for type RN or SN relative to the nominally similar Pt-67 would be insignificant.Coefficients for the individual thermoelements of Type C thermocouples have not been established.1.8 Coefficients fo
11、r sets of inverse polynomials are given in Table 46. These may be used for computing a close approximationof temperature (C) as a function of thermocouple emf. Inverse functions are provided only for thermocouple pairs and are validonly over the emf ranges specified.1.9 This specification is intende
12、d to define the thermoelectric properties of materials that conform to the relationships presentedin the tables of this standard and bear the letter designations contained herein. Topics such as ordering information, physical andmechanical properties, workmanship, testing, and marking are not addres
13、sed in this specification. The user is referred to specificstandards such as Specifications E235, E574, E585/E585M, E608/E608M, E1159, or E2181/E2181M for guidance in these areas.1.10 The temperature-emf data in this specification are intended for industrial and laboratory use.1.11 Thermocouple colo
14、r codes per IEC 5843 are given in Appendix X1.1 These tables are under the jurisdiction of ASTM Committee E20 on Temperature Measurement and are the direct responsibility of Subcommittee E20.04 onThermocouples.Current edition approved May 15, 2011Nov. 1, 2012. Published October 2011November 2012. Or
15、iginally approved in 1963. Last previous edition approved in 20032011as E230 03.E230 111. DOI: 10.1520/E0230_E0230M-11E01.10.1520/E0230_E0230M-12.2 These temperature-emf relationships have been revised as required by the international adoption in 1989 of a revised International Temperature Scale (IT
16、S-90).This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult pri
17、or editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States11.12 The values stated in either SI units
18、or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard.1.12.1 The values stated
19、in brackets are not conversions to the values they succeed and therefore shall be used independentlyof the preceding values.1.12.2 The values given in parentheses are conversions of the values they succeed.1.12.3 Combining values from the two systems may result in non-conformance with the standard.1
20、.13 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Doc
21、uments2.1 ASTM Standards:3E235 Specification for Thermocouples, Sheathed, Type K and Type N, for Nuclear or for Other High-Reliability ApplicationsE574 Specification for Duplex, Base Metal Thermocouple Wire With Glass Fiber or Silica Fiber InsulationE585/E585M Specification for Compacted Mineral-Ins
22、ulated, Metal-Sheathed, Base Metal Thermocouple CableE608/E608M Specification for Mineral-Insulated, Metal-Sheathed Base Metal ThermocouplesE1159 Specification for Thermocouple Materials, Platinum-Rhodium Alloys, and PlatinumE2181/E2181M Specification for Compacted Mineral-Insulated, Metal-Sheathed,
23、 Noble Metal Thermocouples and Thermo-couple Cable2.2 NIST Monograph:NIST Monograph 175 Temperature-Electromotive Force Reference Functions and Tables for the Letter-Designated Thermo-couple Types Based on the ITS-9042.3 IEC Standard:IEC 5843 Thermocouples Part 3: Extension and Compensating Cables T
24、olerances and Identification System, 19893. Source of Data3.1 The data in these tables are based upon the SI volt5 and the International Temperature Scale of 1990 (ITS-90).3.2 The temperature-emf data in Tables 8 to 23 and 26 to 45, together with the corresponding equations in Tables 7 and 46 forall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME230E230M2012RED6793STANDARDSPECIFICATIONANDTEMPERATUREELECTROMOTIVEFORCEEMFTABLESFORSTANDARDIZEDTHERMOCOUPLES

链接地址:http://www.mydoc123.com/p-527180.html