ASTM E220-2007e1 Standard Test Method for Calibration of Thermocouples By Comparison Techniques《用比较技术校准热电偶的标准试验方法》.pdf
《ASTM E220-2007e1 Standard Test Method for Calibration of Thermocouples By Comparison Techniques《用比较技术校准热电偶的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E220-2007e1 Standard Test Method for Calibration of Thermocouples By Comparison Techniques《用比较技术校准热电偶的标准试验方法》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 220 07e1Standard Test Method forCalibration of Thermocouples By Comparison Techniques1This standard is issued under the fixed designation E 220; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.e1NOTEEditorial changes were made throughout in July 2007.1
3、. Scope1.1 This test method describes the principles, apparatus, andprocedure for calibrating thermocouples by comparison with areference thermometer. Calibrations are covered over tempera-ture ranges appropriate to the individual types of thermo-couples within an overall range from approximately 19
4、5 to1700 C (320 to 3100 F).1.2 In general, this test method is applicable to unusedthermocouples. This test method does not apply to usedthermocouples due to their potential material inhomogeneitythe effects of which cannot be identified or quantified bystandard calibration techniques. Thermocouples
5、 with large-diameter thermoelements and sheathed thermocouples mayrequire special care to control thermal conduction losses.1.3 In this test method, all values of temperature are basedon the International Temperature Scale of 1990. See GuideE 1594.1.4 This standard may involve hazardous materials, o
6、pera-tions and equipment. This standard does not purport to addressall of the safety concerns, if any, associated with its use. It isthe responsibility of the user of this standard to establishappropriate safety and health practices and determine theapplicability of regulatory requirements prior to
7、use.2. Referenced Documents2.1 ASTM Standards:2E1 Specification for ASTM Liquid-in-Glass ThermometersE77 Test Method for Inspection and Verification of Ther-mometersE 230 Specification and Temperature-Electromotive Force(EMF) Tables for Standardized ThermocouplesE 344 Terminology Relating to Thermom
8、etry and Hydrom-etryE 452 Test Method for Calibration of Refractory MetalThermocouples Using a Radiation ThermometerE 563 Practice for Preparation and Use of an Ice-Point Bathas a Reference TemperatureE 644 Test Methods for Testing Industrial Resistance Ther-mometersE 988 Temperature-Electromotive F
9、orce (EMF) Tables forTungsten-Rhenium ThermocouplesE 1129/E 1129M Specification for Thermocouple Connec-torsE 1594 Guide for Expression of TemperatureE 1684 Specification for Miniature Thermocouple Connec-torsE 1751 Guide for Temperature Electromotive Force (EMF)Tables for Non-Letter Designated Ther
10、mocouple Combi-nations3. Terminology3.1 DefinitionsThe definitions given in TerminologyE 344 shall apply to this test method.3.2 Definitions of Terms Specific to This Standard:3.2.1 check standard, na measurement instrument orstandard whose repeated results of measurement are used todetermine the re
11、peatability of a calibration process and toverify that the results of a calibration processes are statisticallyconsistent with past results.3.2.2 isothermal block, na piece of solid material of highthermal conductivity used to promote thermal equilibriumbetween two or more thermometers.3.2.3 referen
12、ce junction compensation, nthe adjustmentof the indication of a thermocouple such that the adjustedindication is equivalent to the emf or temperature that thethermocouple would indicate if the reference junctions weremaintained at 0 C.3.2.3.1 DiscussionIn most cases, the thermocouple indi-cation is
13、adjusted by measuring the temperature of a terminalblock where the thermocouple is connected, and then adding tothe thermocouple emf an additional emf equal to the emf of the1This test method is under the jurisdiction of ASTM Committee E20 onTemperature Measurement and is the direct responsibility o
14、f Subcommittee E20.04on Thermocouples.Current edition approved May 1, 2007. Published June 2007. Originallyapproved in 1963. Last previous edition approved in 2002 as E 220 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. Fo
15、r Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.thermocouple reference function evaluated at the temperatureof the ter
16、minal block. Because the emf-temperature relation-ship of any actual thermocouple differs slightly from that of thereference function, reference junction compensation typicallyintroduces higher uncertainties compared to the use of awell-prepared ice bath.3.2.4 reference junction compensator, na devi
17、ce thatimplements reference junction compensation.3.2.5 reference thermometer, nthermometer that estab-lishes the value of temperature in a given system containingadditional temperature sensors.3.2.5.1 DiscussionIn a calibration system the referencethermometer is a calibrated thermometer capable of
18、indicatingvalues of temperature with known uncertainty. The referencethermometer provides the standard temperature for the systemat the time of test.3.2.6 thermocouple type, na standardized thermoelectricclass of thermoelement materials that, used as a pair, have anormal relationship between relativ
19、e Seebeck emf and tem-perature.3.2.6.1 DiscussionFor common, commercially availablethermocouples, a thermocouple type is identified by a letterdesignation (types B, E, J, K, N, R, S, and T). The letterdesignation scheme is given in Specification E 230. The tablesin E 988 and E 1751 give temperature-
20、EMF relationships for anumber of additional thermocouple compositions that are notidentified by a letter designation.4. Summary of Test Method4.1 Comparison calibration consists of measuring the emf ofthe thermocouple being calibrated in an isothermal mediumwhile simultaneously measuring the tempera
21、ture of the me-dium with a reference thermometer. The reference thermom-eter may be any thermometer with sufficient accuracy at thetemperature of calibration.5. Significance and Use5.1 For users or manufacturers of thermocouples, this testmethod provides a means of verifying the emf-temperaturechara
22、cteristics of the material prior to use.5.2 This test method can be used to calibrate a thermocouplefor use as a reference, or it can be used to calibrate thermo-couples representing a batch of purchased, assembled thermo-couples.5.3 This test method can be used for the verification of theconformanc
23、e of thermocouple materials to temperature toler-ances for specifications such as the tables in SpecificationE 230 or other special specifications as required for commer-cial, military, or research applications.6. Interferences6.1 Since the success of this test method depends largelyupon the ability
24、 to maintain the measuring junction of thethermocouple being calibrated and the reference thermometerat the same temperature, considerable care must be taken inchoosing the media and conditions under which the compari-sons are made. Stirred liquid baths, uniformly heated metalblocks, tube furnaces,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME2202007E1STANDARDTESTMETHODFORCALIBRATIONOFTHERMOCOUPLESBYCOMPARISONTECHNIQUES 比较 技术 校准 热电偶 标准 试验

链接地址:http://www.mydoc123.com/p-527155.html