《ASTM E207-2008(2015)e1 5615 Standard Test Method for Thermal EMF Test of Single Thermoelement Materials by Comparison with a Reference Thermoelement of Similar EMF-Temperature Prop.pdf》由会员分享,可在线阅读,更多相关《ASTM E207-2008(2015)e1 5615 Standard Test Method for Thermal EMF Test of Single Thermoelement Materials by Comparison with a Reference Thermoelement of Similar EMF-Temperature Prop.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E207 08 (Reapproved 2015)1Standard Test Method forThermal EMF Test of Single Thermoelement Materials byComparison with a Reference Thermoelement of SimilarEMF-Temperature Properties1This standard is issued under the fixed designation E207; the number immediately following the designatio
2、n indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial changes were made throughout in J
3、une 2015.1. Scope1.1 This test method covers a test for determining thethermoelectric emf of a thermoelement versus NIST platinum67 (Pt-67) by means of measuring the difference between theemf of the test thermoelement and the emf of a referencethermoelement (previously referred to as a secondarystan
4、dard), which has a known relationship to NIST Pt-67.1.2 This test is applicable to new thermocouple materialsover the temperature ranges normally associated with thermo-couples and their extension wires. The table on SuggestedUpper Temperature Limits for Protected Thermocouples inSpecification E230
5、lists the ranges associated with the letter-designated types of thermocouples. ASTM MNL-122lists thetemperature range of extension circuit materials.1.3 This test is not applicable to stability testing or inhomo-geneity testing.1.4 The values stated in SI units are to be regarded as thestandard. The
6、 values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility o
7、f regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E77 Test Method for Inspection and Verification of Ther-mometersE220 Test Method for Calibration of Thermocouples ByComparison TechniquesE230 Specification and Temperature-Electromotive Force(EMF) Tables for Standardize
8、d ThermocouplesE344 Terminology Relating to Thermometry and Hydrom-etryE563 Practice for Preparation and Use of an Ice-Point Bathas a Reference Temperature3. Terminology3.1 DefinitionsThe terms used in this test method aredefined in Terminology E344.3.2 Definitions of Terms Specific to This Standard
9、:3.2.1 reference facility, nNIST, or a testing laboratorywhose physical standards are traceable to NIST or anothernational standards laboratory.3.2.2 test temperature, nthe temperature of the measuringjunction.3.2.2.1 DiscussionIn reporting the results, the value of thetest temperature may be rounde
10、d off, provided the stated testtemperature is within the bounds indicated in 10.10.4. Summary of Test Method4.1 The emf of a thermoelement sample is determined bycomparison to a reference thermoelement that has similarSeebeck coefficients.4.2 This test is conducted on one or more lengths ofspecimens
11、 connected to a single length of the referencethermoelement at a single point. The joined ends are held at thetest temperature, and their opposite ends are held at a constantreference temperature.4.3 The emf of the reference thermoelement relative toPt-67 at several test temperatures are provided by
12、 a referencefacility.1This test method is under the jurisdiction of ASTM Committee E20 onTemperature Measurement and is the direct responsibility of Subcommittee E20.04on Thermocouples.Current edition approved May 1, 2015. Published May 2015. Originallyapproved in 1962 . Last previous edition approv
13、ed in 2008 as E207 08. DOI:10.1520/E0207-08R15E01.2Manual on the Use of Thermocouples in Temperature Measurement, ASTMMNL-12, Fourth Edition, ASTM, April 1993. (Revision of STP 407B).3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.
14、org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.4 The emf of the test thermoelement relative to Pt-67 isdeterm
15、ined by algebraically adding the measured emf to theemf of the reference thermoelement at each test temperature.5. Significance and Use5.1 This test method is designed to calibrate a thermoele-ment at one or more test temperatures. The data obtained aresometimes referred to as initial values of emf
16、because the timeat the test temperature is limited.5.2 This test method is employed mainly by providers ofspools or coils of wire or strips of thermoelectric material.Generally more than one specimen at a time is tested, and theresultant emfs of individual thermoelements are used to matchto companio
17、n thermoelements for use as thermocouples or inextension wiring.5.3 The emf of a thermocouple comprised of two differentthermoelements as tested with this test method may be deter-mined by algebraically subtracting the emf of the negativethermoelement from the emf of the positive thermoelement ata p
18、articular temperature. The emf of a thermocouple may alsobe determined by the test described in Test Method E220, butTest Method E220 does not take into account the values of theemf of the individual thermoelements relative to Pt-67.5.4 This test method is normally used for the calibration ofthermoc
19、ouple materials during their production or distribution,not for the accurate determination of the properties of a usedthermocouple. If the test samples were subjected to previoususe, the test results may not reflect the same emf as thethermocouple did while in service. For example, inhomogene-ities
20、may have been induced in the wires because of a chemicalor metallurgical reaction while in service. Since emf is devel-oped in the thermal gradient, and it is unlikely that thetemperature profile along the wire under testing conditions willbe the same as it was while in service, the test results may
21、 bemisleading.5.5 The test results are suitable for specification acceptance,manufacturing control, design, or research and developmentpurposes.6. Test Specimen6.1 Each sample shall represent one continuous spool, coil,or strip of thermoelectric material. The sample shall consist oftwo specimens, on
22、e cut from each end of the spool, coil, orstrip. The extreme ends shall not be acceptable if they aredistorted or have been subjected to processing dissimilar to thebulk of the spool, coil, or strip.6.2 Insulation or covering shall be removed with care if itinterferes with the test. Straining the te
23、st specimen shall beavoided.6.3 The specimens shall be cleaned of any extraneoussurface contamination.6.4 The specimens and the reference thermoelement shall belong enough to extend continuously from the measuringjunction to the reference junction. A length of 600 to 1200 mm(2 to 4 ft) is generally
24、satisfactory. The exact length dependsupon the depth of immersion in the testing medium and thetransverse size (for example, diameter of round wire, width ofstrip) of the thermoelement.6.4.1 Heating of the measuring junctions shall not affect thetemperature of the reference junctions during the peri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME20720082015E15615STANDARDTESTMETHODFORTHERMALEMFTESTOFSINGLETHERMOELEMENTMATERIALSBYCOMPARISONWITHAREFERENCETHERMOELEMENTOFSIMILAREMFTEMPERATUREPROPPDF

链接地址:http://www.mydoc123.com/p-527130.html