ASTM E165 E165M-2012 red 6736 Standard Practice for Liquid Penetrant Examination for General Industry《一般工业的液体渗透检查的标准实施规程》.pdf
《ASTM E165 E165M-2012 red 6736 Standard Practice for Liquid Penetrant Examination for General Industry《一般工业的液体渗透检查的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E165 E165M-2012 red 6736 Standard Practice for Liquid Penetrant Examination for General Industry《一般工业的液体渗透检查的标准实施规程》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:E16509 Designation: E165/E165M 12Standard Practice forLiquid Penetrant Examination for General Industry1This standard is issued under the fixed designation E165/E165M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice2covers procedures for penetrant examination of materials. Penetrant testing is a nondestructiv
3、e testing methodfor detecting discontinuities that are open to the surface such as cracks, seams, laps, cold shuts, shrinkage, laminations, throughleaks, or lack of fusion and is applicable to in-process, final, and maintenance testing. It can be effectively used in the examinationof nonporous, meta
4、llic materials, ferrous and nonferrous metals, and of nonmetallic materials such as nonporous glazed or fullydensified ceramics, as well as certain nonporous plastics, and glass.1.2 This practice also provides a reference:1.2.1 By which a liquid penetrant examination process recommended or required
5、by individual organizations can be reviewedto ascertain its applicability and completeness.1.2.2 For use in the preparation of process specifications and procedures dealing with the liquid penetrant testing of parts andmaterials. Agreement by the customer requesting penetrant inspection is strongly
6、recommended. All areas of this practice may beopen to agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizantengineering organization.1.2.3 For use in the organization of facilities and personnel concerned with liquid penetrant testing.1.3
7、This practice does not indicate or suggest criteria for evaluation of the indications obtained by penetrant testing. It shouldbe pointed out, however, that after indications have been found, they must be interpreted or classified and then evaluated. For thispurpose there must be a separate code, sta
8、ndard, or a specific agreement to define the type, size, location, and direction ofindications considered acceptable, and those considered unacceptable.1.4The values stated in inch-pound units are to be regarded as the standard. SI units are provided for information only.1.4 UnitsThe values stated i
9、n either SI units or inch-pound units are to be regarded separately as standard. The values statedin each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining valuesfrom the two systems may result in non-conformance with the standard.1.5 Thi
10、s standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2
11、.1 ASTM Standards:3D129 Test Method for Sulfur in Petroleum Products (General High Pressure Decomposition Device Method)E516 Practice for Testing Thermal Conductivity Detectors Used in Gas ChromatographyD808 Test Method for Chlorine in New and Used Petroleum Products (High Pressure Decomposition Dev
12、ice Method)D1193 Specification for Reagent WaterD1552 Test Method for Sulfur in Petroleum Products (High-Temperature Method)D4327 Test Method for Anions in Water by Suppressed Ion ChromatographyE433 Reference Photographs for Liquid Penetrant InspectionE543 Specification for Agencies Performing Nonde
13、structive TestingE1208 Practice for Fluorescent Liquid Penetrant Testing Using the Lipophilic Post-Emulsification ProcessE1209 Practice for Fluorescent Liquid Penetrant Testing Using the Water-Washable ProcessE1210 Practice for Fluorescent Liquid Penetrant Testing Using the Hydrophilic Post-Emulsifi
14、cation Process1This practice is under the jurisdiction of ASTM Committee E07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.03 on Liquid Penetrantand Magnetic Particle Methods.Current edition approved July 1, 2009.June 15, 2012. Published July 2009.2012. Originally ap
15、proved in 1960. Last previous edition approved in 20022009 as E165 - 029.DOI: 10.1520/E0165-09.10.1520/E0165-12.2For ASME Boiler and Pressure Vessel Code applications see related Recommended Test Method SE-165 in the Code.3For referencedASTM standards, visit theASTM website, www.astm.org, or contact
16、ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been
17、made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*
18、A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.E1219 Practice for Fluorescent Liquid Penetrant Testing Using the Solvent-Removable ProcessE1220 Practice for Visible Pen
19、etrant Testing Using Solvent-Removable ProcessE1316 Terminology for Nondestructive ExaminationsE1417 Practice for Liquid Penetrant TestingE1418 Practice for Visible Penetrant Testing Using the Water-Washable Process Practice for Visible Penetrant Testing Using theWater-Washable ProcessE2297 Guide fo
20、r Use of UV-A and Visible Light Sources and Meters used in the Liquid Penetrant and Magnetic ParticleMethods2.2 ASNT Document:4SNT-TC-1A Recommended Practice for Nondestructive Testing Personnel Qualification and CertificationANSI/ASNT CP-189 Standard for Qualification and Certification of Nondestru
21、ctive Testing Personnel2.3 Military Standard:MIL-STD-410 Nondestructive Testing Personnel Qualification and Certification52.4 APHA Standard:429 Method for the Examination of Water and Wastewater62.5 AIA Standard:NAS-410 Certification and Qualification of Nondestructive Test Personnel72.6 SAE Standar
22、ds:8AMS 2644 Inspection Material, PenetrantQPL-AMS-2644 Qualified Products of Inspection Materials, Penetrant3. Terminology3.1 The definitions relating to liquid penetrant examination, which appear in Terminology E1316, shall apply to the terms usedin this practice.4. Summary of Practice4.1 Liquid p
23、enetrant may consist of visible or fluorescent material. The liquid penetrant is applied evenly over the surface beingexamined and allowed to enter open discontinuities. After a suitable dwell time, the excess surface penetrant is removed. Adeveloper is applied to draw the entrapped penetrant out of
24、 the discontinuity and stain the developer. The test surface is thenexamined to determine the presence or absence of indications.NOTE 1The developer may be omitted by agreement between the contracting parties.NOTE 2Fluorescent penetrant examination shall not follow a visible penetrant examination un
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME165E165M2012RED6736STANDARDPRACTICEFORLIQUIDPENETRANTEXAMINATIONFORGENERALINDUSTRY 一般 工业 液体 渗透 检查

链接地址:http://www.mydoc123.com/p-527011.html