《ASTM E154-1999(2005) Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs on Walls or as Ground Cover《混凝土板、墙或土壤覆层的与地面接触的水气隔层的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E154-1999(2005) Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs on Walls or as Ground Cover《混凝土板、墙或土壤覆层的与地面接触的水气隔层的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 154 99 (Reapproved 2005)Standard Test Methods forWater Vapor Retarders Used in Contact with Earth UnderConcrete Slabs, on Walls, or as Ground Cover1This standard is issued under the fixed designation E 154; the number immediately following the designation indicates the year oforiginal
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defen
3、se.1. Scope1.1 These test methods2cover the determination of theproperties of flexible membranes to be used as vapor retardersin contact with earth under concrete slabs, against walls, or asground cover in crawl spaces. The test methods are applicableprimarily to plastic films, and other flexible sh
4、eets. Thematerials are not intended to be subjected to sustained hydro-static pressure. The procedures simulate conditions to whichvapor retarders may be subjected prior to and during installa-tion, and in service.1.2 The test methods included are:SectionWater-Vapor Transmission of Material as Recei
5、ved 7Water-Vapor Transmission after Wetting and Drying and after Long-Time Soaking 8Tensile Strength 9Resistance to Puncture 10Resistance to Plastic Flow and Elevated Temperature 11Effect of Low Temperatures on Flexibility 12Resistance to Deterioration from Organisms and Substances in Con-tacting So
6、il 13Resistance to Deterioration from Petroleum Vehicles for Soil Poisons 14Resistance to Deterioration from Exposure to Ultraviolet Light 15Resistance to Flame Spread 16Report 171.3 The values stated in acceptable metric units shall beconsidered standard. The values in parentheses are for infor-mat
7、ion only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Ref
8、erenced Documents2.1 ASTM Standards:3C 168 Terminology Relating to Thermal InsulationC 755 Practice for Selection of Water Vapor Retarders forThermal InsulationD 828 Test Method for Tensile Properties of Paper andPaperboard Using Constant-Rate-of-Elongation ApparatusD 1709 Test Methods for Impact Re
9、sistance of Plastic Filmby the Falling Dart MethodD 1985 Practice for Preparing Concrete Blocks for TestingSealants for Joints and CracksD 2565 Practice for Operating Xenon Arc Exposure ofPlastics Intended for Outside ApplicationsD 4397 Specification for Polyethylene Sheeting for Con-struction, Indu
10、strial, and Agricultural ApplicationsE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE96 Test Methods for Water Vapor Transmission of Mate-rialsE 241 Guide for Limiting Water-Induced Damage to Build-ingsE 437 Specification for Industrial Wire Cloth and Screens(Square Opening
11、Series)4E 631 Terminology of Building Constructions3. Terminology3.1 Definitions: For definitions of terms used in these testmethods, see Terminologies C 168 and E 631.3.2 Definitions of Terms Specific to This Standard:3.2.1 perm, nthe time rate of water vapor migrationthrough a material or a constr
12、uction of 1 grain/hft2in. Hg ofvapor pressure difference.3.2.1.1 DiscussionThere are no SI units that can becombined to give the same mass flow rate as the inch-pound1These test methods are under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and are the direct responsibility of S
13、ubcommittee E06.21on Serviceability.Current edition approved Dec. 1, 2005. Published December 2005. Originallyapproved in 1959. Last previous edition approved in 1999 as E 154 99.2Some of these test methods were based originally on Report No. 2040, U.S.Forest Products Laboratory, and “Vapor Barrier
14、Materials for Use with Slab-On-Ground Construction and as Ground Covers in Crawl Spaces,” Publication445-1956, Building Research Advisory Board (currently out-of-print).3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annua
15、l Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.perm without a numerical coefficient. If a specification statestha
16、t a one perm resistance is required, the same rate of flowwill be obtained from the following relationships:1 perm = 1 grain/hft2in. Hg Inch-pound units= 57.21012kg/sm2Pa SI (fundamental units)= 57.2 ng/sm2Pa SI (frequently used)= 0.66 g/24 hm2mm Hg SI (deprecated, should not be used)The perm is a s
17、pecific rate of vapor flow regardless of the units thatwere used in measuring the flow rate or in converting them into desiredunits.3.2.2 watervapor permeability, n the time rate of watervapor flow through unit area of unit thickness of a flat materialinduced by unit vapor pressure difference betwee
18、n two parallelspecified surfaces under specific temperature and humidityconditions.3.2.2.1 DiscussionSince vapor flow rate does not varydirectly with thickness for many materials, comparisons ofvapor flow rates for retarders of various thicknesses should bemade on test results of permeance rather th
19、an on permeability.3.2.3 watervapor permeance, nthe time rate of watervapor flow through unit area of the known thickness of a flatmaterial or a construction normal to two specific parallelsurfaces induced by unit vapor pressure difference between thetwo surfaces under specific temperature and humid
20、ity condi-tions. While the SI unit is kg/sm2Pa, the practical unit is theperm (see 3.2.1).3.2.4 watervapor transmission (WVT), nthe steady wa-ter vapor flow in unit time through unit area of a flat materialor a construction normal to specific parallel surfaces inducedby specific temperatures, pressu
21、res, and humidities at eachsurface. Units in SI are kilogram per second, square metre,(kg/sm2) (inch-pound, grain per hour, square foot, (grain/hft2).4. Significance and Use4.1 In service, vapor retarders may be exposed to a varietyof conditions, so no one test will provide evaluations related toper
22、formance for all exposures (refer to Guide E 241 andC 755). Neither will all test methods listed be necessary in allevaluations for specific exposures (see 16.2).4.2 LimitationsPrior to use and in service, vapor retardersmay be exposed to a variety of conditions so no one test willprovide evaluation
23、s related to performance for all exposures(refer to Guide E 241 and C 755). Neither will all tests benecessary in all evaluations for specific exposures. Conse-quently, the tests and required test results shall be agreed uponby the purchaser and the supplier (see 16.2).5. Sampling5.1 Obtain samples
24、for preparation of test specimens fromeach of three separate rolls or packages of each type of materialbeing tested. Samples shall be representative of the materialbeing tested and shall be of uniform thickness. If the samplesare of nonsymmetrical construction, designate the two faces bydistinguishi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME15419992005STANDARDTESTMETHODSFORWATERVAPORRETARDERSUSEDINCONTACTWITHEARTHUNDERCONCRETESLABSONWALLSORASGROUNDCOVER

链接地址:http://www.mydoc123.com/p-526981.html