《ASTM E147-1961(2017) 2485 Standard Specification for Apparatus for Microdetermination of Nitrogen by Kjeldahl Method《用基耶达法进行氮气微量测定用仪器》.pdf》由会员分享,可在线阅读,更多相关《ASTM E147-1961(2017) 2485 Standard Specification for Apparatus for Microdetermination of Nitrogen by Kjeldahl Method《用基耶达法进行氮气微量测定用仪器》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E147 61 (Reapproved 2017)Standard Specification forApparatus for Microdetermination of Nitrogen by KjeldahlMethod1This standard is issued under the fixed designation E147; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers digestion and distillation ap-paratus used for the microdetermination of nitro
3、gen by theKjeldahl method, and modifications thereof at atmosphericpressure.NOTE 1This specification is based on those originally developed bythe Committee on Microchemical Apparatus, Division of AnalyticalChemistry, American Chemical Society.22. Referenced Documents2.1 ASTM Standards:3E124 Specific
4、ation for Weighing and Drying Apparatus forMicrochemical Analysis3. Tolerances3.1 The following commercial length tolerance shall beadhered to, unless otherwise specified:Up to 10 mm 1 mm10 to 100 mm 2 mm100 to 200 mm 3 mm200 mm 4 mm4. Digestion Flasks4.1 Digestion flasks of three types shall confor
5、m to therequirements prescribed in Table 1 and Fig. 1, Fig. 2, and Fig.3. The flasks shall be made of shock-resistant glass with linearcoefficient of expansion not greater than 33.5 107cm/cmC.NOTE 2The weighing tubes described in Specification E124 Figs.1214 are recommended for introducing solid sam
6、ples into the microKjeldahl digestion flasks. Combustion boats, Fig. 1 and Fig. 2 ofSpecification E124, are recommended for use with waxy and nonvolatileliquid samples.5. Digestion Rack5.1 The micro Kjeldahl digestion rack shall be portable andshall consist of flask heaters (either gas or electric),
7、 a flasksupport, and a fume duct. The rack shall be supplied with a heatdeflector mounted under the burners to prevent overheating ofthe bench top.5.1.1 HeatersThe source of heat may be either electric orgas. In operation, each heater shall supply sufficient heat to a30-mL flask to cause 15 mL of wa
8、ter at 25C to come to arolling boil in not less than 2 or more than 3 min.Adevice shallbe provided for regulating the amount of heat supplied to theflask so that these conditions can be met. The amount of heatsupplied to the flasks also shall be so adjustable that low-temperature digestions are poss
9、ible. Switches and controlsshall be conveniently located and shall remain cool enough tohandle even after long periods of operation.NOTE 3Boiling chips shall be added when testing the heaters tominimize superheating, and the burners and rack shall be at equilibriumtemperature.5.1.2 Flask SupportThe
10、support on which the bulbs of theflasks rest shall shield the necks of the flasks from excessiveheating during digestion and shall be provided with circularopenings not exceeding 26 mm in diameter, centered over eachheater.5.1.3 Fume DuctThe fume duct shall provide means foradequately removing the f
11、umes evolved during the digestionand shall support the necks of the flasks at an angle greater than35 to the horizontal. Fume ducts meeting these specificationsare shown in Fig. 4 and Fig. 5. The fume duct illustrated in Fig.4 is supported and held in place by suitable clamps mounted ateither end of
12、 the digestion rack. The fume duct in Fig. 5 restsupon a circular support plate and is held in place by springsfrom the plate to the four glass hooks. The concave centerpermits clearance for the nut which fastens the support plate tothe center support post.6. One-Piece Distillation Apparatus6.1 The
13、one-piece model distillation apparatus shall con-form to the requirements of Fig. 6. The steam-generator vesselillustrated in Fig. 7 and the immersion heater in Fig. 8 are1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Su
14、bcommitteeE41.01Laboratory Ware and Supplies.Current edition approved Jan. 1, 2017. Published February 2017. Originallyapproved in 1959. Last previous edition approved in 2011 as E147 61 (2011).DOI: 10.1520/E0147-61R17.2Committee on Microchemical Apparatus, “Recommended Specification forMicrochemica
15、lApparatus, Micro Kjeldahl Nitrogen,” Analytical Chemistry, Vol 23,1951, p. 523.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME147196120172485STANDARDSPECIFICATIONFORAPPARATUSFORMICRODETERMINATIONOFNITROGENBYKJELDAHLMETHOD

链接地址:http://www.mydoc123.com/p-526979.html