ASTM E114-1995(2005) Standard Practice for Ultrasonic Pulse-Echo Straight-Beam Examination by the Contact Method《用接触法做超声脉冲回波纵波检验》.pdf
《ASTM E114-1995(2005) Standard Practice for Ultrasonic Pulse-Echo Straight-Beam Examination by the Contact Method《用接触法做超声脉冲回波纵波检验》.pdf》由会员分享,可在线阅读,更多相关《ASTM E114-1995(2005) Standard Practice for Ultrasonic Pulse-Echo Straight-Beam Examination by the Contact Method《用接触法做超声脉冲回波纵波检验》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 114 95 (Reapproved 2005)Standard Practice forUltrasonic Pulse-Echo Straight-Beam Examination by theContact Method1This standard is issued under the fixed designation E 114; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice2cover
3、s ultrasonic examination of materi-als by the pulse-echo method using straight-beam longitudinalwaves introduced by direct contact of the search unit with thematerial being examined.1.2 This practice shall be applicable to development of anexamination procedure agreed upon by the users of thedocumen
4、t.1.3 The values stated in inch-pound units are to be regardedas the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and deter
5、mine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E 317 Practice for Evaluating Performance Characteristicsof Ultrasonic Pulse-Echo Examination Instruments andSystems without the Use of Electronic Measurement In-strumentsE 543 Practice for Agen
6、cies Performing NondestructiveTestingE 1316 Terminology for Nondestructive Testing2.2 ASNT Standards:4SNT-TC-1A Recommended Practice for Personnel Qualifi-cation and Certification in Nondestructive TestingANSI/ASNT CP-189 ASNT Standard for Qualification andCertification of Nondestructive Testing Per
7、sonnel2.3 Other Documents:NAS-410 Certification and Qualification of NondestructiveTest Personnel53. Terminology3.1 Refer to Terminology E 1316 for definitions of termsused in this practice.4. Basis of Application4.1 Purchaser-Supplier Agreements:The following items require agreement between the usi
8、ngparties for this practice to be used effectively:4.1.1 Qualification of Nondestructive Testing AgenciesAgreement is required as to whether the nondestructive testingagency, as defined in Practice E 543 must be formally evalu-ated and qualified to perform the examination. If such evalu-ation and qu
9、alification is specified, a documented proceduresuch as Practice E 543 shall be used as the basis for evaluation.4.1.2 Personnel QualificationNondestructive testing(NDT) personnel shall be qualified in accordance with anationally recognized NDT personnel qualification practice orstandard such asANSI
10、/ASNT CP-189, SNT-TC-1A, NAS-410,or a similar document. The practice or standard used and itsapplicable revision shall be specified in the contractual agree-ment between the using parties.4.1.3 Extent of ExaminationThe extent of the examina-tion shall be determined by agreement of the using parties.
11、4.1.4 Time of ExaminationThe time of examination shallbe determined by agreement of the using parties.4.1.5 Interpretation CriteriaThe criteria by which theultrasonic signals and part acceptability will be evaluated andshall be determined by agreement of the using parties.5. Significance and Use5.1
12、A series of electrical pulses is applied to a piezoelectricelement (transducer) which converts these pulses to mechani-cal energy in the form of pulsed waves at a nominal frequency.This transducer is mounted in a holder so it can transmit the1This practice is under the jurisdiction of ASTM Committee
13、 E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.06 onUltrasonic Method.Current edition approved Dec. 1, 2005. Published February 2006. Originallyapproved in 1955. Last previous edition approved in 2001 as E 114 - 95 (2001).2For ASME Boiler and Pressure Vessel Cod
14、e applications see related PracticeSE-114 in Section II of that Code.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
15、website.4Available fromAmerican Society for Nondestructive Testing (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 43228-0518.5Available from Aerospace Industries Association of America, Inc. (AIA), 1250Eye St., NW, Washington, DC 20005.1Copyright ASTM International, 100 Barr Harbor Drive, P
16、O Box C700, West Conshohocken, PA 19428-2959, United States.waves into the material through a suitable wear surface andcouplant. The assembly of transducer, holder, wearface, andelectrical connnector comprise the search unit.5.2 Pulsed energy is transmitted into materials, travels in adirection norm
17、al to the contacted surface, and is reflected backto the search unit by discontinuity or boundary interfaceswhich are parallel or near parallel to the contacted surface.These echoes return to the search unit, where they areconverted from mechanical to electrical energy and are ampli-fied by a receiv
18、er. The amplified echoes (signals) are usuallypresented in an A-scan display, such that the entire round tripof pulsed energy within the resolution of the system may beindicated along the horizontal base line of the display byvertical deflections corresponding to echo amplitudes fromeach interface,
19、including those from intervening discontinui-ties. By adjustment of the sweep (range) controls, this displaycan be expanded or contracted to obtain a designated relationbetween the displayed signals and the material reflectors fromwhich the signal originates. Thus a scaled distance to adiscontinuity
20、 and its displayed signal becomes a true relation-ship. By comparison of the displayed discontinuity signalamplitudes to those from a reference standard, both locationand estimated discontinuity size may be determined. Discon-tinuities having dimensions exceeding the size of the soundbeam can also b
21、e estimated by determining the amount ofmovement of a search unit over the examination surface wherea discontinuity signal is maintained.NOTE 1When determining the sizes of discontinuities by either ofthese two practices, only the area of the discontinuity which reflectsenergy to the search unit is
22、determined.5.3 Types of information that may be obtained from thepulsed-echo straight-beam practice are as follows:5.3.1 Apparent discontinuity size (Note 2) by comparison ofthe signal amplitudes from the test piece to the amplitudesobtained from a reference standard.5.3.2 Depth location of disconti
23、nuities by calibrating thehorizontal scale of the A-scan display.5.3.3 Material properties as indicated by the relative soundattenuation or velocity changes of compared items.5.3.4 The extent of bond and unbond (or fusion and lack offusion) between two ultrasonic conducting materials if geom-etry an
24、d materials permit.NOTE 2The term “apparent” is emphasized since true size depends onorientation, composition, and geometry of the discontinuity and equip-ment limitations.6. Apparatus6.1 Complete ultrasonic apparatus shall include the follow-ing:6.1.1 InstrumentationThe ultrasonic instrument shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME11419952005STANDARDPRACTICEFORULTRASONICPULSEECHOSTRAIGHTBEAMEXAMINATIONBYTHECONTACTMETHOD 接触法 超声

链接地址:http://www.mydoc123.com/p-526874.html