ASTM D7997-2015 0306 Standard Practice for Polyurethane Raw Materials Gel Tests for Polyurethane Non-Foam Formulations《聚亚胺酯原材料的标准实施规程 聚氨酯非发泡剂的凝胶试验》.pdf
《ASTM D7997-2015 0306 Standard Practice for Polyurethane Raw Materials Gel Tests for Polyurethane Non-Foam Formulations《聚亚胺酯原材料的标准实施规程 聚氨酯非发泡剂的凝胶试验》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7997-2015 0306 Standard Practice for Polyurethane Raw Materials Gel Tests for Polyurethane Non-Foam Formulations《聚亚胺酯原材料的标准实施规程 聚氨酯非发泡剂的凝胶试验》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7997 15Standard Practice forPolyurethane Raw Materials: Gel Tests for PolyurethaneNon-Foam Formulations1This standard is issued under the fixed designation D7997; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers procedures for determining the geltimes of polyurethane non-foam formulations using commer-
3、cially available gel test equipment.1.2 Definitions, terms, and techniques are described alongwith procedures for calculating sample weights.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport
4、to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this sta
5、ndard.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to Plastics3. Terminology3.1 DefinitionsFor general definitions of terms used in thispractice see Terminology D883.3.2 Definitions of Terms Specific to This Standard:3.2.1 gel pointthe extent of polymerization at which theupp
6、er limit, as defined by the procedure being run, is reached.3.2.2 gel timethe time from the initiation of the reaction tothe gel point.3.2.3 resin blend (formulated polyol)complete ingredientformulation without the isocyanate component.3.2.4 indexthe ratio of the equivalents of the isocyanatecompone
7、nt to the equivalents of the resin blend of a polyure-thane formulation.4. Summary of Practice4.1 The gel time of a polyurethane non-foam formulation isdetermined by measuring the time required for the viscosity ofthe polymerizing system to increase to a set level using a gelmeter. It is recommended
8、 that the torque of the gel meter beverified with a gauge certified to NIST standards.5. Significance and Use5.1 General Utility:5.1.1 This practice is suitable for research, quality control,specification testing and process control.5.1.2 It is useful to define and verify the reactivity ofnon-foam p
9、olyurethane formulations.5.2 Limitations:5.2.1 Operator-to-operator variability and lab-to-lab vari-ability can be significant.5.2.2 The variability of this practice is dependent on theequipment used to measure the gel time. It is recommendedthat the testing laboratory and the client agree on the eq
10、uipmentand the conditions to be used that include the following:5.2.2.1 Gel Tester and gel point criteria,5.2.2.2 Speed/rpm of the mixer,5.2.2.3 Type and shape of the mix blades,5.2.2.4 Size and type (for example, shape, lined or unlined)of container for mixing the components and for measuring thege
11、l time, and5.2.2.5 The volume (or height) of material to be placed inthe container for measuring the gel time and the depth of themeasuring wire or spindle of the gel tester from the bottom ofthe container.5.2.3 The estimation of precision in this practice is verylimited. Users of this practice shal
12、l develop their own precisiondata to determine if these procedures meet their requirements.5.2.4 It is possible that low-levels (ppm, ppb) of contami-nants will not be detected using this practice.6. Sampling6.1 Since organic isocyanates react with atmosphericmoisture, take special precautions in sa
13、mpling. Usual sampling1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.22 on Cellular Materials -Plastics and Elastomers.Current edition approved Nov. 15, 2015. Published December 2015. DOI:10.1520/D799715.2For referenc
14、ed ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Con
15、shohocken, PA 19428-2959. United States1methods, even when conducted rapidly, can cause contamina-tion of the sample with insoluble urea. Therefore, blanket thesample with dry air or nitrogen at all times. (WarningDiisocyanates are eye, skin and respiratory irritants at concen-trations above the occ
16、upational exposure limit (TLV or PEL).Diisocyanates can cause skin and respiratory sensitization(asthma) in some people. Once sensitized, it is essential to limitfurther exposure to diisocyanates. Use a combination ofengineering controls and personal protective equipment, in-cluding respiratory, ski
17、n and eye protection, to prevent over-exposure to diisocyanates. Consult the product suppliersSafety Data Sheet (SDS) for more detailed information aboutpotential health effects and other specific safety and handlinginstructions for the product.)7. Test Conditions7.1 Isocyanate samples shall remain
18、sealed against moistureuntil immediately before testing.8. Equipment and Reagents8.1 Commercial gel meter or other equipment capable ofdetermining a large increase in viscosity that occurs in apolymerizing urethane system at or near the gel point.8.2 Balance, capable of weighing to 0.1 mg.8.3 Contai
19、ners appropriate for the particular gel test beingrun.8.4 Stopwatch or electronic timer.8.5 Heating device as described in the specific procedure.8.6 Methyl ethyl ketone (MEK) or other solvent appropriatefor cleaning the equipment after use.8.7 Motorized mixer with blades (or spatula for manualmixin
20、g).8.8 Two component non-foam polyurethane formulationconsisting of a resin blend as needed to obtain the desired geltime and an isocyanate component.NOTE 2Additional equipment may be listed in specific procedures inthe Appendixes.9. General Procedure9.1 A general procedure is outlined below with ex
21、amples ofspecific steps provided in the Appendixes.9.1.1 Charge the container used in the gel test with acarefully weighed amount of the resin blend and the isocyanatebeing reacted. A 1.05 index is typical for gel tests but can beadjusted for a specific test or formulation.9.1.2 Immediately start th
22、e timer or stopwatch and mix thecomponents thoroughly (the timer is to be started at thebeginning of the mix, that is, when the reaction is initiated).9.1.3 Introduce the container with the reacting system to thegel meter and monitor the reaction. Because some formulationssolidify, consider using di
23、sposable stirring paddles or probes.9.1.4 Stop the timer when the reaction reaches the gel point.Many commercial units will shut off automatically at thedefined gel point.9.1.5 Record the gel time.10. Sample Calculations10.1 Calculate the equivalent weight, EWp, of the resinblend as follows:EWp5100O
24、H1 Ac!100561001%W9(1)where:OH = the hydroxyl number of the resin blend in milli-grams of KOH per gram of sample,Ac = the acid number of the resin blend in milligrams ofKOH per gram of sample,%W = the percent water in the resin blend,56100 = the equivalent weight of KOH in milligrams ofKOH per equiva
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD799720150306STANDARDPRACTICEFORPOLYURETHANERAWMATERIALSGELTESTSFORPOLYURETHANENONFOAMFORMULATIONS

链接地址:http://www.mydoc123.com/p-526614.html