ASTM D7962-2015 8821 Standard Practice for Determination of Minimum Immersion Depth and Assessment of Temperature Sensor Measurement Drift《测定温度传感器最小浸入深度以及评估测得漂移的标准实践规程》.pdf
《ASTM D7962-2015 8821 Standard Practice for Determination of Minimum Immersion Depth and Assessment of Temperature Sensor Measurement Drift《测定温度传感器最小浸入深度以及评估测得漂移的标准实践规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7962-2015 8821 Standard Practice for Determination of Minimum Immersion Depth and Assessment of Temperature Sensor Measurement Drift《测定温度传感器最小浸入深度以及评估测得漂移的标准实践规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7962 15Standard Practice forDetermination of Minimum Immersion Depth andAssessment of Temperature Sensor Measurement Drift1This standard is issued under the fixed designation D7962; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes a two procedures for use withtemperature measurement devices. Methodo
3、logy is describedfor determining minimum immersion depth for thermalsensors, in particular RTDs or similar temperature sensors.Included is a procedure for consistently preparing a referencebath for the purpose of monitoring measurement drift ofthermal sensors such as liquid-in-glass or digital conta
4、ctthermometers.1.2 This practice focuses on temperature measurement driftin a laboratory. If the user requires greater measurementaccuracy, then they should follow the instructions in PracticeE563.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are incl
5、uded in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior t
6、o use.2. Referenced Documents2.1 ASTM Standards:2E563 Practice for Preparation and Use of an Ice-Point Bathas a Reference Temperature3. Terminology3.1 Definitions:3.1.1 ice-point bath, nphysical system containing ice andwater assembled to realize the ice point as a referencetemperature, or to establ
7、ish a constant temperature near 0 C.3.1.2 minimum immersion length, ndepth that a thermom-eter should be immersed, in a uniform temperatureenvironment, such that further immersion does not produce achange in indicated temperature greater than the specifiedtolerance.4. Summary of Practice4.1 This pra
8、ctice describes a procedure for consistentlypreparing an ice bath that is an intimate mixture of crushed iceor ice particles and water in a thermally insulating vessel opento the atmosphere.4.1.1 Cautionwhen the ice bath is not made from distilledwater, its temperature will differ from the natural f
9、ixed-pointtemperature by a consistent amount, typically less than0.02 C. If the user needs a more accurate ice point, then theyshould use Practice E563 to prepare the ice bath.4.2 This practice includes a procedure for determining theminimum immersion depth of the temperature sensor using anice bath
10、.4.2.1 This procedure determines minimum immersion depthwith a 25 C differential between sensed temperature andambient temperature. If the probe is subjected to a greaterdifferential temperature, a larger immersion depth may berequired to correctly measure the temperature.5. Significance and Use5.1
11、This practice provides a means for the users of ASTMCommittee D02 standards to monitor the drift in sensedtemperature of liquid-in-glass thermometer (LiG), and digitalcontact thermometers (DCT). Digital contact thermometers aresometimes referred to as portable electronic thermometers(PET) or simply
12、digital thermometers.5.2 This practice is not suitable for determining the accu-racy or calibration of a temperature measuring device as theerror in the ice bath temperature can be greater than 0.02 C.For greater accuracy, the user should use Practice E563 toprepare the ice bath.5.3 The ice point is
13、 a common practical industrial referencepoint of thermometry. The ice point is relatively simple torealize and provides a readily available natural fixed-pointreference temperature.1This practice is under the jurisdiction of ASTM Committee D02 on PetroleumProducts, Liquid Fuels, and Lubricants and i
14、s the direct responsibility of Subcom-mittee D02.91 on Coordinating Subcommittee on Thermometry.Current edition approved April 1, 2015. Published April 2015. DOI: 10.1520/D7962-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org
15、. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.4 This practice only checks the measurement drift at asingle temp
16、erature. It will not detect a change in measurementresponse with change in temperature. Temperature measuringdevices should be recalibrated at set intervals. See devicesupplier for recommendations.5.5 This practice provides a technique to determine mini-mum immersion depth of the sensing probe of th
17、e thermometerusing an ice bath. The minimum immersion depth determinedby this practice may change when the differential temperaturediffers significantly from the conditions described. A greaterdifferential will likely increase the minimum immersion depth.6. Reagents and Equipment6.1 WaterGood qualit
18、y drinking water from a consistentsource.6.2 IceCrushed ice prepared from the water in 6.1.6.3 Insulated containeran insulated container largeenough to hold the thermometer and provide several centime-ters of water-ice slush around the measuring portion of thethermometer.7. ProcedureDrift in Tempera
19、ture Measurement7.1 Preparation of the Ice-Point Bath:7.1.1 Determine the water source to be used each time thispractice is followed in your laboratory to determine measure-ment drift and note the water source with the measurement.Altering the water source between uses of the practice whenmonitoring
20、 a temperature sensor may result in observing a falsedrift.7.1.2 Ensure that all equipment is clean and free of any oilyresidue. Rinse the equipment with the type of water used forthe ice-point bath medium. Use clean, “powder free” labora-tory gloves to handle the ice and equipment.7.1.3 Prepare ice
21、 by using the water from the sourcedetermined in 7.1.1. Chill a quantity of the water to near 0 Cin a flask then shake vigorously to aerate the water beforefreezing in small cubes or thin sheets.7.1.3.1 Prepare finely divided ice by shaving or crushing.Shaved ice resembling snow is preferred, but cr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD796220158821STANDARDPRACTICEFORDETERMINATIONOFMINIMUMIMMERSIONDEPTHANDASSESSMENTOFTEMPERATURESENSORMEASUREMENTDRIFT

链接地址:http://www.mydoc123.com/p-526572.html