ASTM D7946-2014 7298 Standard Test Method for Initial pH &40 i-pH&41 -Value of Petroleum Products《石油产品初始pH (i-pH) 值的标准试验方法》.pdf
《ASTM D7946-2014 7298 Standard Test Method for Initial pH &40 i-pH&41 -Value of Petroleum Products《石油产品初始pH (i-pH) 值的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7946-2014 7298 Standard Test Method for Initial pH &40 i-pH&41 -Value of Petroleum Products《石油产品初始pH (i-pH) 值的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7946 14Standard Test Method forInitial pH (i-pH)-Value of Petroleum Products1This standard is issued under the fixed designation D7946; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numb
2、er in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for the determina-tion of initial pH (i-pH) in new and in-service lubricants.NOTE 1In new and used oils,
3、 the constituents that may be consideredto have characteristics influencing the i-pH value include organic andinorganic acids, esters, phenolic compounds, lactones, resins, salts ofheavy metals, salts of ammonia and other weak bases, acid salts ofpolybasic acids, and addition agents such as inhibito
4、rs and detergents.“Initial” is used to differentiate from aqueous systems. The analysis isterminated after a defined time interval whenever equilibrium conditions,as known for pH measurements in aqueous systems, are not reached (see3.1.1.2)1.2 This test method is used to indicate relative changes th
5、atoccur in oil during use under oxidizing conditions or due tocontamination by blow-by gases of combustion processes ofbiogases regardless of the color or other properties of thein-service lubricants. Although the initial pH is made underdefinite equilibrium conditions, the test method is not intend
6、edto measure an absolute acidic property that can be used topredict performance of oil under service conditions. No generalcorrelation between corrosion of non-ferrous bearing metalsand initial pH value is known.1.3 The values stated in SI units are to be regarded asstandard. No other units of measu
7、rement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limi
8、tations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum Products3. Terminology3.1 Definitions:3.1.1 initial pH (i-pH), nth
9、e measure of the hydrogen ion(H+) concentration when a fixed sample amount of lubricationoil is dissolved into a fixed volume of solvent and using aspecified detection system.3.1.1.1 DiscussionThis test method expresses the amountof dissociated acidic components as i-pH of a sample in amixture of to
10、luene and propan-2-ol to which a small amount ofwater has been added.3.1.1.2 DiscussionThe measured i-pH is called initialsince the original definition of the pH-scale depends onaqueous solutions. Its application to organic solutions will notgive stable electrode potential for all types of samples.
11、Apotential reading after a defined time is used in those casesinstead.4. Summary of Test Method4.1 The oil sample is dissolved in solvent mixture and thei-pH value is measured using a glass indicating electrode anda reference electrode or a combination electrode. The meterreadings are measured manua
12、lly or automatically.5. Significance and Use5.1 New and used petroleum products may contain acidicconstituents that are present as additives, degradation productsformed during service, such as oxidation products or compo-nents formed from combustion gases. The i-pH-value is ameasure of the amount of
13、 acidic substances and their aciditydefined under the conditions of test. The i-pH-value is used asa measure of lubricant degradation in service.5.2 The corrosiveness of acidic components depends ontheir concentration and acidity. The i-pH-value is a measure ofthe amount of dissociated acidic compon
14、ents with the potentialof corrosiveness towards metals.5.3 Since a variety of oxidation and blow-by productscontribute to the i-pH-value, this test method cannot be used topredict corrosiveness of oil or blends under service conditionsagainst metallic components. No general correlation is knownbetwe
15、en i-pH-value and the corrosive tendency of blends oroils toward metals.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.06 on Analysis of Lubricants.Current edition approved July
16、1, 2014. Published August 2014. DOI: 10.1520/D7946-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyrig
17、ht ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Apparatus6.1 pH-MeterMeter, a voltmeter or a potentiometer, thatwill operate with an accuracy of 60.005 V and a sensitivity of60.002 V over a range of at least 6 0.5 V when the meter isused
18、with the electrodes specified in 6.2 to 6.4 and when theresistance between the electrodes falls within the range from0.2 M to 20 M. The meter shall be protected from strayelectrostatic fields so that no permanent change in the meterreadings over the entire operating range is produced bytouching, wit
19、h a grounded lead, any part of the exposed surfaceof the glass electrode, the glass electrode lead, the stirrer, or themeter.NOTE 2A suitable apparatus could consist of a continuous-readingelectronic voltmeter designed to operate on an input of less than510-12A, when an electrode system having a res
20、istance of 1000-Mis connectedacross the meter terminals and provided with a metal shield connected tothe ground, as well as a satisfactory terminal to connect the shieldedconnection wire from the glass electrode to the meter without interferencefrom any external electrostatic field.6.2 Sensing Elect
21、rode, Standard pH, suitable for nonaque-ous media.6.3 Reference Electrode, Silver/Silver Chloride (Ag/AgCl)Reference Electrode, filled with 1 mol/L to 3 molL LiCl inethanol.6.4 Combination ElectrodesSensing electrodes may havethe Ag/AgCl reference electrode built into the same electrodebody, which o
22、ffers the convenience of working with andmaintaining only one electrode. The combination electrodeshall have a sleeve junction on the reference compartment andshall use an inert ethanol electrolyte, for example, 1 mol/Lto3 molL LiCl in ethanol. These combination electrodes shallhave the same respons
23、e or better response than a dual electrodesystem. They shall have movable sleeves for easy rinsing andaddition of electrolyte.6.5 Variable-Speed Mechanical Stirrer, a suitable type,equipped with a propeller-type stirring paddle. The rate ofstirring shall be sufficient to produce vigorous agitation w
24、ithoutspattering and without stirring air into the solution.Apropellerwith blades 6 mm in radius and set at a pitch of 30 to 45 issatisfactory. A magnetic stirrer is also satisfactory. If anelectrical stirring apparatus is used, it shall be electricallycorrect and grounded so that connecting or disc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD794620147298STANDARDTESTMETHODFORINITIALPH40IPH41VALUEOFPETROLEUMPRODUCTS 石油 产品 初始 PHIPH 标准 试验 方法

链接地址:http://www.mydoc123.com/p-526549.html