ASTM D7852-2013 4375 Standard Practice for Use of an Electrically Conductive Geotextile for Leak Location Surveys《调查泄漏位置用导电土工织物使用的标准实施规程》.pdf
《ASTM D7852-2013 4375 Standard Practice for Use of an Electrically Conductive Geotextile for Leak Location Surveys《调查泄漏位置用导电土工织物使用的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7852-2013 4375 Standard Practice for Use of an Electrically Conductive Geotextile for Leak Location Surveys《调查泄漏位置用导电土工织物使用的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7852 13Standard Practice forUse of an Electrically Conductive Geotextile for LeakLocation Surveys1This standard is issued under the fixed designation D7852; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This standard practice describes standard procedures forusing a conductive geotextile with electrical methods to locat
3、eleaks in exposed geomembranes and geomembranes coveredwith water or earth materials containing moisture.1.2 This standard practice provides guidance for the use ofappropriate conductive geotextile used in leak location surveyon geomembrane. This guide includes all types of conductivegeotextile with
4、 sufficient conductivity for the particular elec-trical leak location method. A conductive geotextile is appli-cable to all types of geoelectric surveys when there is otherwisenot a conductive layer under the geomembrane.1.3 The leak stream itself being adequately conductive. Aconductive geotextile
5、is applicable to all types of geoelectricsurveys when there is otherwise not a conductive layer underthe geomembrane.1.4 This standard practice is intended to ensure that leaklocation surveys can always be performed with a reasonablelevel of certainty. This standard practice provides guidance forthe
6、 use of appropriate conductive geotextile used in leaklocation survey on geomembranes.1.5 Leak location surveys can be used on non-conductivegeomembranes installed in basins, ponds, tanks, ore and wastepads, landfill cells, landfill caps, other containment facilitiesand building applications such as
7、 in parking garages, decks andgreen roofs. The procedures are applicable for geomembranesmade of non conductive materials such as polyethylene,polypropylene, polyvinyl chloride, chlorosulfonatedpolyethylene, bituminous material, and other electrically-insulating materials. Leak location survey invol
8、ving conduc-tive or partially conductive geomembranes are not within thescope of this document.1.6 WarningThe electrical methods used for geomem-brane leak location could use high voltages, resulting in thepotential for electrical shock or electrocution. This hazardmight be increased because operati
9、ons might be conducted inor near water. In particular, a high voltage could exist betweenthe water or earth material and earth ground, or any groundedconductor. These procedures are potentially VERYDANGEROUS, and can result in personal injury or death.Because of the high voltage that could be involv
10、ed, and theshock or electrocution hazard, do not come in electrical contactwith any leak unless the excitation power supply is turned off.The electrical methods used for geomembrane leak locationshould be attempted only by qualified and experienced person-nel. Appropriate safety measures must be tak
11、en to protect theleak location operators as well as other people at the site.1.7 This standard guide does not purport to address all ofthe safety and liability concerns, if any, associated with its use.It is the responsibility of the user of this standard guide toestablish appropriate safety and hea
12、lth practices and deter-mine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4439 Terminology for GeosyntheticsD6747 Guide for Selection of Techniques for ElectricalDetection of Leaks in GeomembranesD7002 Practice for Leak Location on Exposed Geom
13、em-branes Using the Water Puddle SystemD7007 Practices for Electrical Methods for Locating Leaksin Geomembranes Covered with Water or Earth Materials3. Terminology3.1 For general definitions related to geosynthetics, seeTerminology D44393.2 Definitions:3.2.1 conductive geotextile, na geotextile fabr
14、icated in aplant using conductive materials, in part or in whole, andproviding a sufficient electrical conductivity to perform elec-trical leak location. D70023.2.2 electrical leak location, nany method which useselectrical current or electrical potential to locate leaks. D70021This practice is unde
15、r the jurisdiction of ASTM Committee on Geosyntheticsand is the direct responsibility of Subcommittee D35.10 on Geomembranes.Current edition approved Jan. 15, 2013. Published February 2012. DOI:10.1520/D7852132For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custom
16、er Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.3 leak, nfor the purposes of this
17、document, a leak isany unintended opening, perforation, breach, slit, tear,puncture, crack, or seam breach through which liquid can flow.Scratches, gouges, dents, or other aberrations that do notcompletely penetrate the geomembrane are not considered tobe leaks. Leaks detected during surveys have be
18、en groupedinto five categories: (1) Holesround shaped voids which mayor may not have downward or upward protruding rims, (2)Tearslinear or areal voids with irregular edge borders, (3)Linear cutslinear voids with neat close edges, (4) Seamdefectsarea of separation between sheets, and (5) Burnedthroug
19、h zonesareas where the polymer has been meltedduring the welding process. D70023.2.4 water, nfor the purposes of this document, waterincludes electrolytes and electrically conductive solutions suchas wastewater, brine, leachate, or any other conductive liquid.D70024. Summary of Practice4.1 The princ
20、iple of the electrical leak location method is toplace a voltage across a geomembrane and then locate areaswhere electrical current flows through discontinuities in thegeomembrane and at seams. It requires an electrically conduc-tive layer below the geomembrane.4.2 The electrical leak location surve
21、y can be applied toexposed and covered geomembranes. The various electricalleak location methods are described in Guide D6747. Stan-dards procedures for the relevant leak location methods aredescribed in Practices D7002 and D7007.4.3 Appropriate conductive geotextiles can be used as theconductive me
22、dia that is needed under the geomembrane. Themethods described in Guide D6747 will require various levelsof conductivity of the geotextile, depending on the method, theconductivity of the media on the geomembrane, the thicknessof the material on the geomembrane, the leak detectioncapabilities of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD785220134375STANDARDPRACTICEFORUSEOFANELECTRICALLYCONDUCTIVEGEOTEXTILEFORLEAKLOCATIONSURVEYS 调查

链接地址:http://www.mydoc123.com/p-526419.html