《ASTM D7764-2012 0311 Standard Practice for Pre-Installation Acceptance Testing of Vibrating Wire Piezometers《振动丝压力计预安装验收试验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7764-2012 0311 Standard Practice for Pre-Installation Acceptance Testing of Vibrating Wire Piezometers《振动丝压力计预安装验收试验的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7764 12Standard Practice forPre-Installation Acceptance Testing of Vibrating WirePiezometers1This standard is issued under the fixed designation D7764; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes two acceptance tests for avibrating wire piezometer: a zero test and a down-hole test. Thetwo tests
3、 can help a user verify that the piezometer is operatingproperly before it is installed.1.2 This practice offers an organized collection of informa-tion or a series of options and does not recommend a specificcourse of action. This document cannot replace education orexperience and should be used in
4、 conjunction with professionaljudgment. Not all aspects of this practice may be applicable inall circumstances. This ASTM standard is not intended torepresent or replace the standard of care by which theadequacy of a given professional service must be judged, norshould this document be applied witho
5、ut consideration of aprojects many unique aspects. The word “standard” in thetitle of this document means only that the document has beenapproved through the ASTM consensus process.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstan
6、dard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referen
7、ced Documents2.1 ASTM Standards:2D653 Terminology Relating to Soil, Rock, and ContainedFluidsD3740 Practice for Minimum Requirements for AgenciesEngaged in Testing and/or Inspection of Soil and Rock asUsed in Engineering Design and Construction3. Terminology3.1 Definitions:3.1.1 For general definiti
8、ons, see Terminology D653.3.1.2 absolute pressure, na pressure value that includesthe effect of atmospheric pressure.3.1.3 gauge pressure, na pressure value that excludes theeffect of atmospheric pressure.3.1.4 vibrating wire piezometer, na type of pressure sensorthat is used to monitor pore-water p
9、ressure. Vibrating wirerefers to the mechanism by which pressure on the sensorsdiaphragm is converted to an electrical signal that is transmit-ted to a readout device. A typical vibrating wire piezometerreports absolute pressure, rather than gauge pressure. In thisstandard, the words “vibrating wire
10、 piezometer,” “piezometer,”and “sensor” will be used interchangably.4. Significance and Use4.1 Vibrating wire piezometers are typically not recoverableafter installation. Replacement, which involves drilling a newborehole, is expensive and sometimes impossible. Thus it isimportant to be certain that
11、 the sensor is operational before itis installed.4.2 Lacking sophisticated testing facilities, field testers mustuse equipment that is at hand. But in so doing, field testersshould not expect to achieve the same accuracy and precisionthat manufacturers state on the sensor calibration record.Instead,
12、 field testers should look for obvious non-conformances, as explained in the procedures.4.3 This standard practice is not meant to restrict the use ofother appropriate acceptance tests and procedures.NOTE 1Notwithstanding the statements on precision and bias con-tained in this practice, the precisio
13、n of this practice is dependent on thecompetence of the personnel performing it and the suitability of theequipment and facilities used. Agencies that meet the criteria of PracticeD3740 are generally considered capable of competent and objectivetesting. Users of this practice are cautioned that comp
14、liance with PracticeD3740 does not itself ensure reliable testing. Reliable testing depends onmany factors; Practice D3740 provides a means of evaluating some ofthese factors.1This practice is under the jurisdiction of ASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommitt
15、ee D18.23 on Field Instrumen-tation.Current edition approved July 1, 2012. Published October 2012. DOI: 10.1520/D7764-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refe
16、r to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Equipment5.1 A readout in good working condition and compatiblewith the sensor to be tested. Consult manufacturers usermanu
17、al to verify compatibility of the readout.5.2 The calibration record for the sensor to be tested.Vibrating wire sensors typically have unique calibrations, so itis important to match the calibration record to the sensor.6. Zero-Reading Test Procedure6.1 This procedure is used to verify that the sens
18、or readsapproximately zero when only atmospheric pressure is applied.6.2 Ideally, this procedure is conducted in a temperature-stable location, since changes in temperature can affect thesensor. At minimum, ensure that the sensor is kept out of directsunlight and away from other sources of heat.6.3
19、Suspend the sensor in air by its signal cable and allowapproximately one hour for the sensor to reach thermalequilibrium with the surrounding air. Do not handle the sensorduring this time or during the test.6.4 Connect the signal cable to the readout and obtain areading according to the manufacturer
20、s instructions. Typically,the reading will be in Hz or Hz2/1000. Check that the readingis stable and repeatable. Readings that vary 62Hzor612Hz2/1000 should be regarded as unstable. If the reading isunstable, check that the excitation setting is correct.Also checkif other sensors of the same type re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD776420120311STANDARDPRACTICEFORPREINSTALLATIONACCEPTANCETESTINGOFVIBRATINGWIREPIEZOMETERS 振动 压力计

链接地址:http://www.mydoc123.com/p-526276.html