ASTM D7741 D7741M-2011e1 5625 Standard Test Method for Measurement of Apparent Viscosity of Asphalt-Rubber or Other Asphalt Binders by Using a Rotational Hand Held Viscometer《用手持旋转.pdf
《ASTM D7741 D7741M-2011e1 5625 Standard Test Method for Measurement of Apparent Viscosity of Asphalt-Rubber or Other Asphalt Binders by Using a Rotational Hand Held Viscometer《用手持旋转.pdf》由会员分享,可在线阅读,更多相关《ASTM D7741 D7741M-2011e1 5625 Standard Test Method for Measurement of Apparent Viscosity of Asphalt-Rubber or Other Asphalt Binders by Using a Rotational Hand Held Viscometer《用手持旋转.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7741/D7741M 111Standard Test Method forMeasurement of Apparent Viscosity of Asphalt-Rubber orOther Asphalt Binders by Using a Rotational Hand HeldViscometer1This standard is issued under the fixed designation D7741/D7741M; the number immediately following the designation indicates they
2、ear of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEThe designation of this standard was changed in 2012 to ref
3、lect its combined-units status.1. Scope1.1 The use of high viscosity asphalt binders like Asphalt-Rubber is becoming more common in the United States andworldwide. Specifications such as Specification D6114 note theneed for field control of the apparent viscosity and require theuse of a field produc
4、tion rotational viscometer. The testing ofAsphalt-Rubber Binder for use in Asphalt- Rubber Hot Mixand for Asphalt-Rubber Membrane is necessary to ensureconsistent mix properties that will ensure good performance ofthese materials. Logistics of field applications limits the use ofconventional laborat
5、ory controls and testing equipment. Thistest, using a hand held rotational viscometer can be conductedin either the field or laboratory to determine the apparentviscosity of Asphalt-Rubber and other high viscosity bindersfor field production control and to assess the uniformity of thebinder produced
6、 or for other related purposes.1.2 Asphalt-Rubber Binder consists of a blend of pavinggrade asphalt cement and crumb rubber as described inSpecification D6114. Other high viscosity asphalt binders mayconsist of asphalts modified with polymer or fiber or both.Testing is performed following the specif
7、ied reaction time, ifany, within the production process. Control of the raw materi-als is separate from the test.1.3 The values stated in SI units or inch-pound units are tobe regarded separately as standard. The values stated in eachsystem may not be exact equivalents; each system shall be usedinde
8、pendently of the other. Combining values from the twosystems may result in non-compliance with the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety
9、and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D6114 Specification for Asphalt-Rubber Binder3. Significance and Use3.1 This test is primarily used for field production control ofAsphalt-Rubber (A-R) and other hi
10、gh viscosity binders; how-ever the test can also be used in a laboratory setting.3.2 Ahand held rotational viscometer is used to measure theapparent viscosity of a completed blend of A-R or highviscosity binder. A rotor (spindle), turning at constant speed, isinserted in the liquid binder to be meas
11、ured. The resistance tomovement of the spindle (torque) caused by the viscosity of thesurrounding liquid is measured using a special mechanism toobtain direct readings in Pas or cP.NOTE 1Spindle generally made of stainless steel, although anothermetal such as brass could be used.3.3 The measured app
12、arent viscosity is used to control theproduction of the A-R or other high viscosity binder, to assessthe uniformity of the binder produced or for other relatedpurposes.3.4 As the spindle turns in the A-R or other high viscositybinder, it has a tendency to “drill” into the sample (i.e., forA-R,the sp
13、indle spins the rubber particles out of the measurementarea). Consequently, the apparent viscosity drops to reflect onlythe liquid phase of the high viscosity binder. Therefore, thepeak viscosity measurement value is recorded to reflect theviscosity of the blended material.4. Apparatus4.1 Viscometer
14、hand held rotational type viscometer (seeFig. 1). The viscometer shall be equipped with a level bubbleto ensure proper orientation of the viscometer in the sample to1This test method is under the jurisdiction of ASTM Committee D04 on Roadand Paving Materials and is the direct responsibility of Subco
15、mmittee D04.44 onRheological Tests.Current edition approved Dec. 1, 2011. Published January 2012. Last publishedJanuary 2012 as D774111. DOI: 10.1520/D7741_D7741M11E012For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual
16、Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.be tested. Spindle (rotor) speed typically 62.5 rpm, howevermay vary with diffe
17、rent manufacturers.4.2 Spindle (Rotor)Diameter - 24 6 1.1 mm. 1.0 6 0.05inch; Height - 53 6 0.1 mm 2 6 .005 inch or equivalent (seeFig. 2).4.3 ThermometerDigital with metal jacket probe, 1 de-gree C 2 degree F precision.4.4 Sample Can4 liter 1 gallon metal can with wire bale.4.5 Viscosity Standard O
18、ilsCalibrated in absolute viscos-ity in Pas centipoises cP and in the range of 1.0 to 5.0 Pas1000 to 5000 cP.4.6 Controllable heat source, such as a hot plate, gas stoveor burner, etc., to maintain the test temperature of the A-R orhigh viscosity binder sample during viscosity measurement.4.7 Viscom
19、eter holderclean metal can or some type offrame where the viscometer can be stored between tests.5. Calibration Verification5.1 Calibration of the rotational viscometer shall be verifiedprior to use at each site per manufacturers instructions usingthe reference viscosity standard oils.6. Sampling6.1
20、 The sample shall consist of at least 3 liters 0.75 gal ofthe completed mixture of A-R or other high viscosity binder.Obtain the sample from an appropriate sample valve located tointercept the normal flow of material during production.Perform sampling and testing in close proximity to the plantopera
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7741D7741M2011E15625STANDARDTESTMETHODFORMEASUREMENTOFAPPARENTVISCOSITYOFASPHALTRUBBEROROTHERASPHALTBINDERSBYUSINGAROTATIONALHANDHELDVISCOMETER

链接地址:http://www.mydoc123.com/p-526225.html