ASTM D7710-2014 7958 Standard Test Method for Determination of Volume and Density of Rigid and Irregularly Shaped Molded Cellular Materials《测定刚性和不规则形状模制多胞材料的体积和密度的标准试验方法》.pdf
《ASTM D7710-2014 7958 Standard Test Method for Determination of Volume and Density of Rigid and Irregularly Shaped Molded Cellular Materials《测定刚性和不规则形状模制多胞材料的体积和密度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7710-2014 7958 Standard Test Method for Determination of Volume and Density of Rigid and Irregularly Shaped Molded Cellular Materials《测定刚性和不规则形状模制多胞材料的体积和密度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7710 14Standard Test Method forDetermination of Volume and Density of Rigid andIrregularly Shaped Molded Cellular Materials1This standard is issued under the fixed designation D7710; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is used to determine the volume anddensity of irregularly shaped molded pro
3、ducts.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establis
4、h appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2E691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a
5、Test Method3. Summary of Test Method3.1 This test method is used to determine the volume ofirregular shaped materials. It uses displacement volume testingto determine the volume occupied by a specimen. This testmethod is used on materials that do not compress easily.Molded flexible and semi-rigid po
6、lyurethane foam are theprimary application for this test method although it is possiblethere will be other uses for this test method.4. Significance and Use4.1 The test procedure provides a standard method ofobtaining data for research and development, quality control,acceptance and rejection under
7、specifications and for specialpurposes.4.2 The data obtained by this test method is applicable to thematerial under the conditions of this particular test and are notnecessarily the same as obtained under other environments inuse.5. Interferences5.1 Successful application of this test method is depe
8、ndenton the ability of the media to surround the test samplepositioned in the test vessel and fill in all the open space.6. Apparatus6.1 Test vessel constructed as outlined in Section 10.7. Reagents and Materials7.1 Low-density polyethylene (LDPE) media (unfoamed)approximately 4 mm in diameter. Medi
9、a shall be uniform insize and appearance.7.1.1 The precision and bias statement was made using datafrom an interlaboratory study (ILS) using LDPE media. Othermaterials are potentially suitable for use but are not addressedin this test method.7.1.2 The polyethylene media shall hereafter be referred t
10、oas “media” to accommodate other material as outlined in 7.1.1.8. Hazards8.1 No hazards have been identified with this test method.9. Sampling, Test Specimens, and Test Units9.1 One specimen from a mold or cavity is to be tested at atime.9.2 Test units are SI units.10. Preparation of Apparatus10.1 T
11、est Vessel Construction:10.1.1 Test vessel shall allow at least 25 mm on each side ofthe specimen.10.1.2 Test vessel is a square or rectangular box made of arigid transparent plastic such as an acrylic or polycarbonate.This is to allow for visual inspection of the media during thefilling process, en
12、suring that the media has minimal spacingbetween particles, between the part and the vessel walls, and isproperly settled.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.22 on Cellular Materials -Plastics and Elastomer
13、s.Current edition approved Aug. 1, 2014. Published September 2014. DOI:10.1520/D7710-142For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summar
14、y page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States110.1.3 Top of vessel has a hinged lid that is firmly securedwith a latch on the side opposite the hinges. Reinforce the lidto ensure that the lid remains flat.1
15、0.2 Center of test vessel lid has a 76 6 3 mm diameter holein the center for filling of the media10.3 For vessels greater than 750 cm2additional holes shallbe evenly spaced in the lid. Use one hole for every 400 cm2(overlapping is permitted).10.4 Small vessels are to be turned upside down to pour ou
16、tthe media. Large boxes are to have a plug installed on the sideof the box to pour out the media.11. Calibration and Standardization11.1 Calibration of Test Vessel: Method A (DisplacementMethod)11.1.1 Pour media into a graduated cylinder. Gently tap thecylinder three times to settle the media in the
17、 cylinder. It isimportant to fill the vessel consistently. When filling the vessel,the media shall be poured to overflowing and a straight edgelarger than the opening dragged over the opening to provide alevel and consistent surface. Repeat after any action that wouldcause the material to settle.11.
18、1.1.1 Record volume and place media into test vessel.11.1.1.2 Continue filling the test vessel through hole in thelid using the method in 11.1.1. Periodically lift box 25 mmfrom surface and drop three times to settle the media. (Verylarge vessels shall be shaken instead of dropped if the weightof th
19、e apparatus is too great to be safely picked up anddropped.)11.1.1.3 Repeat 11.1.1.2 until the vessel is full.11.1.1.4 Record the volume (Va) of media needed to com-pletely fill the vessel, to the nearest millilitre.11.1.1.5 Conduct the test five times and record the averagevolume of the vessel (V0)
20、.11.1.1.6 Calculate theoretical volume by measuring thelength, width, and height of the boxs interior in centimetres.Multiply these values together and compare to the averagevolume (V0). If the difference is more than 2 mL, repeatcalibration (11.1).11.2 Calibration of Vessel: Method B (Bulk Density
21、Method)11.2.1 Weigh a one litre graduated cylinder to the nearest0.1 g and record as (W1).11.2.2 Pour media into a graduated cylinder. Gently tap thecylinder three times to settle the media in the cylinder.11.2.3 Add more media if needed. Repeat 11.2.2 until thecylinder is full.11.2.4 When the cylin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD771020147958STANDARDTESTMETHODFORDETERMINATIONOFVOLUMEANDDENSITYOFRIGIDANDIRREGULARLYSHAPEDMOLDEDCELLULARMATERIALS

链接地址:http://www.mydoc123.com/p-526148.html