ASTM D7691-2011e1 7496 Standard Test Method for Multielement Analysis of Crude Oils Using Inductively Coupled Plasma Atomic Emission Spectrometry &40 ICP-AES&41 《用电感耦合等离子体原子发射光谱法 (.pdf
《ASTM D7691-2011e1 7496 Standard Test Method for Multielement Analysis of Crude Oils Using Inductively Coupled Plasma Atomic Emission Spectrometry &40 ICP-AES&41 《用电感耦合等离子体原子发射光谱法 (.pdf》由会员分享,可在线阅读,更多相关《ASTM D7691-2011e1 7496 Standard Test Method for Multielement Analysis of Crude Oils Using Inductively Coupled Plasma Atomic Emission Spectrometry &40 ICP-AES&41 《用电感耦合等离子体原子发射光谱法 (.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7691 111Standard Test Method forMultielement Analysis of Crude Oils Using InductivelyCoupled Plasma Atomic Emission Spectrometry (ICP-AES)1This standard is issued under the fixed designation D7691; the number immediately following the designation indicates the year oforiginal adoption
2、or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEAppendix X2 was editorially corrected in August 2014.1. Scope1.1 This test method co
3、vers the determination of severalelements (including iron, nickel, sulfur, and vanadium) occur-ring in crude oils.1.2 For analysis of any element using wavelengths below190 nm, a vacuum or inert gas optical path is required.1.3 Analysis for elements such as arsenic, selenium, orsulfur in whole crude
4、 oil may be difficult by this test methoddue to the presence of their volatile compounds of theseelements in crude oil; but this test method should work forresid samples.1.4 Because of the particulates present in crude oil samples,if they do not dissolve in the organic solvents used or if they donot
5、 get aspirated in the nebulizer, low elemental values mayresult, particularly for iron and sodium. This can also occur ifthe elements are associated with water which can drop out ofthe solution when diluted with solvent.1.4.1 An alternative in such cases is using Test MethodD5708, Procedure B, which
6、 involves wet decomposition of theoil sample and measurement by ICP-AES for nickel,vanadium, and iron, or Test Method D5863, Procedure A,which also uses wet acid decomposition and determinesvanadium, nickel, iron, and sodium using atomic absorptionspectrometry.1.4.2 From ASTM Interlaboratory Crossch
7、eck Programs(ILCP) on crude oils data available so far, it is not clear thatorganic solvent dilution techniques would necessarily givelower results than those obtained using acid decompositiontechniques.1.4.3 It is also possible that, particularly in the case ofsilicon, low results may be obtained i
8、rrespective of whetherorganic dilution or acid decomposition is utilized. Silicones arepresent as oil field additives and can be lost in ashing. Silicatesshould be retained but unless hydrofluoric acid or alkali fusionis used for sample dissolution, they may not be accounted for.1.5 This test method
9、 uses oil-soluble metals for calibrationand does not purport to quantitatively determine insolubleparticulates. Analytical results are particle size dependent andlow results may be obtained for particles larger than a fewmicrometers.1.6 The precision in Section 18 defines the concentrationranges cov
10、ered in the interlaboratory study. However, lowerand particularly higher concentrations can be determined bythis test method. The low concentration limits are dependent onthe sensitivity of the ICP instrument and the dilution factorused. The high concentration limits are determined by theproduct of
11、the maximum concentration defined by the calibra-tion curve and the sample dilution factor.1.7 Elements present at concentrations above the upper limitof the calibration curves can be determined with additionalappropriate dilutions and with no degradation of precision.1.8 As a generality based on th
12、is interlaboratory study (see18.1), the trace elements identifiable in crude oils can bedivided into three categories:1.8.1 Element levels that are too low for valid detection byICP-AES and hence, cannot be determined: aluminum, barium,lead, magnesium, manganese, and silicon.1.8.2 Elements that are
13、just at the detection levels of theICP-AES method and hence, cannot be determined with a greatdeal of confidence: boron, calcium, chromium, copper,molybdenum, phosphorus, potassium, sodium, and zinc. Per-haps the determination of these elements can be considered assemi-quantitative.1.8.3 Elements th
14、at are at higher levels of concentration andcan be determined with good precision: iron, nickel, sulfur, andvanadium.1.9 The detection limits for elements not determined by thistest method follow. This information should serve as anindication as to what elements are not present above thedetection li
15、mits typically obtainable by ICP-AES instruments.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.03 on Elemental Analysis.Current edition approved Jan. 1, 2011. Published February
16、 2011. DOI: 10.1520/D769111E01.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1Element mg/kgAluminum 1Barium 0.2Boron 1Calcium 0.1Chromium 0.1Copper 0.1Lead 1.4Magnesium 1Manganese 0.1Molybdenum 0.2Phosphorous 1Potassium 0.5Silicon 4Z
17、inc 0.51.10 This test method determines all possible elementssimultaneously and is a simpler alternative to Test MethodsD5184, D5708,orD5863.1.11 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.12 This standard does not purpor
18、t to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C1109
19、 Practice for Analysis of Aqueous Leachates fromNuclear Waste Materials Using Inductively CoupledPlasma-Atomic Emission SpectroscopyD1552 Test Method for Sulfur in Petroleum Products (High-Temperature Method)D4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Auto
20、matic Sampling of Petroleum andPetroleum ProductsD4307 Practice for Preparation of Liquid Blends for Use asAnalytical StandardsD5184 Test Methods for Determination of Aluminum andSilicon in Fuel Oils by Ashing, Fusion, InductivelyCoupled Plasma Atomic Emission Spectrometry, andAtomic Absorption Spec
21、trometryD5185 Test Method for Multielement Determination ofUsed and Unused Lubricating Oils and Base Oils byInductively Coupled Plasma Atomic Emission Spectrom-etry (ICP-AES)D5708 Test Methods for Determination of Nickel,Vanadium, and Iron in Crude Oils and Residual Fuels byInductively Coupled Plasm
22、a (ICP) Atomic EmissionSpectrometryD5854 Practice for Mixing and Handling of Liquid Samplesof Petroleum and Petroleum ProductsD5863 Test Methods for Determination of Nickel,Vanadium, Iron, and Sodium in Crude Oils and ResidualFuels by Flame Atomic Absorption SpectrometryD6299 Practice for Applying S
23、tatistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6792 Practice for Quality System in Petroleum Productsand Lubricants Testing LaboratoriesD7260 Practice for Optimization, Calibration, and Valida-tion of Inductively Coupled Plasma-Atomic
24、 EmissionSpectrometry (ICP-AES) for Elemental Analysis of Petro-leum Products and LubricantsE135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Related Materials3. Terminology3.1 For the definition of emission spectroscopy, refer toTerminology E135.3.2 Definitions of Terms Specifi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD76912011E17496STANDARDTESTMETHODFORMULTIELEMENTANALYSISOFCRUDEOILSUSINGINDUCTIVELYCOUPLEDPLASMAATOMICEMISSIONSPECTROMETRY40ICPAES41

链接地址:http://www.mydoc123.com/p-526118.html