ASTM D7645-2010e1 2500 Standard Test Method for Determination of Aldicarb Aldicarb Sulfone Aldicarb Sulfoxide Carbofuran Methomyl Oxamyl and Thiofanox in Water by Liquid Chromatogr.pdf
《ASTM D7645-2010e1 2500 Standard Test Method for Determination of Aldicarb Aldicarb Sulfone Aldicarb Sulfoxide Carbofuran Methomyl Oxamyl and Thiofanox in Water by Liquid Chromatogr.pdf》由会员分享,可在线阅读,更多相关《ASTM D7645-2010e1 2500 Standard Test Method for Determination of Aldicarb Aldicarb Sulfone Aldicarb Sulfoxide Carbofuran Methomyl Oxamyl and Thiofanox in Water by Liquid Chromatogr.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7645 101Standard Test Method forDetermination of Aldicarb, Aldicarb Sulfone, AldicarbSulfoxide, Carbofuran, Methomyl, Oxamyl and Thiofanox inWater by Liquid Chromatography/Tandem MassSpectrometry (LC/MS/MS)1This standard is issued under the fixed designation D7645; the number immediate
2、ly following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEThis Test Method
3、 was changed editorially in 2012.1. Scope1.1 This test method covers the determination of aldicarb,aldicarb sulfone, aldicarb sulfoxide, carbofuran, methomyl,oxamyl, and thiofanox (referred to collectively as carbamatesin this test method) in water by direct injection using liquidchromatography (LC)
4、 and detected with tandem mass spec-trometry (MS/MS). These analytes are qualitatively and quan-titatively determined by this method. This method adheres tomultiple reaction monitoring (MRM) mass spectrometry.1.2 The Detection Verification Level (DVL) and ReportingRange for the carbamates are listed
5、 in Table 1.1.2.1 The DVL is required to be at a concentration at least3 times below the Reporting Limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 displays the signal/noiseratios of the primary single reaction monitoring (SRM) transi-tions, and Fig. 2 displays the confirmatory SRM
6、transitions atthe DVLs for the carbamates.1.2.2 The reporting limit is the concentration of the Level 1calibration standard as shown in Table 2 for the carbamates.1.3 UnitsThe values stated in SI units are to be regardedas standard. No other units of measurement are included in thisstandard.1.4 This
7、 standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents
8、2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3694 Practices for Preparation of Sample Containers andfor Preservation of Organic ConstituentsD3856
9、Guide for Management Systems in LaboratoriesEngaged in Analysis of WaterD4841 Practice for Estimation of Holding Time for WaterSamples Containing Organic and Inorganic ConstituentsD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE2554 Practice for
10、Estimating and Monitoring the Uncer-tainty of Test Results of a Test Method in a SingleLaboratory Using a Control Sample Program1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substanc
11、es in Water.Current edition approved June 1, 2010. Published February 2012. DOI: 10.1520/D7645-10E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards D
12、ocument Summary page onthe ASTM website.TABLE 1 Detection Verification Level and Reporting RangeAnalyteDVL(ng/L)Reporting Range(g/L)Aldicarb 250 1-100Aldicarb Sulfone 250 1-100Aldicarb Sulfoxide 250 1-100Carbofuran 250 1-100Methomyl 250 1-100Oxamyl 250 1-100Thiofanox 250 1-1001Copyright ASTM Interna
13、tional, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.FIG. 1 Example Primary SRM Chromatograms Signal/Noise RatiosFIG. 2 Example Confirmatory SRM Chromatograms Signal/Noise RatiosD7645 10122.2 Other Documents:3EPApublication SW-846 Test Methods for Evaluating So
14、lidWaste, Physical/Chemical MethodsEPA Method 531 Measurement of N-Methyl Carbamoylox-imes and N-Methyl Carbamates in Drinking Water byDirect Aqueous Injection HPLC with Post Column De-rivatizationEPA Method 531.2 Measurement ofN-Methylcarbamoyloximes and N-Methylcarbamates inWater by Direct Aqueous
15、 Injection HPLC with Postcol-umn DerivatizationEPA Method 538 Determination of Selected Organic Con-taminants in Drinking Water by Direct Aqueous Injection-Liquid Chromatography/Tandem Mass Spectrometry(DAI-LC/MS/MS)3. Terminology3.1 Definitions:3.1.1 carbamates, nin this test method, aldicarb, aldi
16、carbsulfone, aldicarb sulfoxide, carbofuran, methomyl, oxamyl,and thiofanox collectively.3.1.2 detection verification level, DVL, na concentrationthat has a signal/noise ratio greater than 3:1 and is at least 3times below the Reporting Limit (RL).3.1.3 reporting limit, RL, nthe concentration of thel
17、owest-level calibration standard used for quantification.3.2 Abbreviations:3.2.1 mMmillimolar, 1 3 10-3moles/L3.2.2 NDnon-detect3.2.3 pptparts per trillion, ng/L4. Summary of Test Method4.1 This is a performance based method, and modificationsare allowed to improve performance.4.2 For carbamate anal
18、ysis, samples are shipped to the labacidified between 0C and 6C and analyzed within 14 days ofcollection. In the lab, the samples are spiked with surrogates,filtered using a syringe driven filter unit, and analyzed directlyby LC/MS/MS.4.3 The carbamates, methomyl-13C2,15N (surrogate) andcarbofuran-1
19、3C6(surrogate) are identified by retention time andtwo SRM transitions. The target analytes and surrogate arequantitated using the primary SRM transitions utilizing anexternal calibration. The final report issued for each samplelists the concentration of carbamates and the surrogate recov-eries.5. S
20、ignificance and Use5.1 This test method has been developed by US EPARegion5 Chicago Regional Laboratory (CRL).5.2 The N-methyl carbamate (NMC) pesticides: aldicarb,carbofuran, methomyl, oxamyl, and thiofanox have been iden-tified by EPAas working through a common mechanism. Theseaffect the nervous s
21、ystem by reducing the ability of enzymes.Enzyme inhibition was the primary toxicological effect ofregulatory concern to EPA in assessing the NMCs food,drinking water, and residential risks. In most of the country,NMC residues in drinking water sources are at levels that arenot likely to contribute s
22、ubstantially to the multi-pathwaycumulative exposure. Shallow private wells extending throughhighly permeable soils into shallow, acidic ground waterrepresent what the EPA believes to be the most vulnerabledrinking water. Aldicarb sulfone and aldicarb sulfoxide arebreakdown products of aldicarb and
23、should also be monitoreddue to their toxicological effects.45.3 This method has been investigated for use with reagent,surface, and drinking water for the selected carbamates:aldicarb, aldicarb sulfone, aldicarb sulfoxide, carbofuran,methomyl, oxamyl and thiofanox.6. Interferences6.1 Method interfer
24、ences may be caused by contaminants insolvents, reagents, glassware, and other apparatus producingdiscrete artifacts or elevated baselines. All of these materialsare demonstrated to be free from interferences by analyzinglaboratory reagent blanks under the same conditions assamples.6.2 All glassware
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD76452010E12500STANDARDTESTMETHODFORDETERMINATIONOFALDICARBALDICARBSULFONEALDICARBSULFOXIDECARBOFURANMETHOMYLOXAMYLANDTHIOFANOXINWATERBYLIQUIDCHROMATOGRPDF

链接地址:http://www.mydoc123.com/p-526015.html