ASTM D7644-2010 4375 Standard Test Method for Determination of Bromadiolone Brodifacoum Diphacinone and Warfarin in Water by Liquid Chromatography Tandem Mass Spectrometry (LC MS M.pdf
《ASTM D7644-2010 4375 Standard Test Method for Determination of Bromadiolone Brodifacoum Diphacinone and Warfarin in Water by Liquid Chromatography Tandem Mass Spectrometry (LC MS M.pdf》由会员分享,可在线阅读,更多相关《ASTM D7644-2010 4375 Standard Test Method for Determination of Bromadiolone Brodifacoum Diphacinone and Warfarin in Water by Liquid Chromatography Tandem Mass Spectrometry (LC MS M.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7644 10Standard Test Method forDetermination of Bromadiolone, Brodifacoum, Diphacinoneand Warfarin in Water by Liquid Chromatography/TandemMass Spectrometry (LC/MS/MS)1This standard is issued under the fixed designation D7644; the number immediately following the designation indicates
2、the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This procedure covers the determination of broma
3、di-olone, brodifacoum, diphacinone and warfarin (referred tocollectively as rodenticides in this test method) in water bydirect injection using liquid chromatography (LC) and detectedwith tandem mass spectrometry (MS/MS). These analytes arequalitatively and quantitatively determined by this method.T
4、his method adheres to multiple reaction monitoring (MRM)mass spectrometry.1.2 The Detection Verification Level (DVL) and ReportingRange for the rodenticides are listed in Table 1.1.2.1 The DVL is required to be at a concentration at least3 times below the Reporting Limit (RL) and have a signal/noise
5、 ratio greater than 3:1. Fig. 1 displays the signal/noiseratios of the primary single reaction monitoring (SRM) transi-tions, and Fig. 2 displays the confirmatory SRM transitions atthe DVLs for the rodenticides.1.2.2 The reporting limit was calculated from the concen-tration of the Level 1 calibrati
6、on standard, as shown in Table 4,accounting for the dilution of a 40 mL water sample up to afinal volume of 50 mL with methanol to ensure analytesolubility.1.3 UnitsThe values stated in SI units are to be regardedas standard. No other units of measurement are included in thisstandard.1.4 This standa
7、rd does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 AST
8、M Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3694 Practices for Preparation of Sample Containers andfor Preservation of Organic ConstituentsD3856 Guide f
9、or Good Laboratory Practices in Laborato-ries Engaged in Sampling and Analysis of WaterD4841 Practice for Estimation of Holding Time for WaterSamples Containing Organic and Inorganic ConstituentsD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE255
10、4 Practice for Estimating and Monitoring the Uncer-tainty of Test Results of a Test Method in a SingleLaboratory Using a Control Sample Program2.2 Other Documents:EPApublication SW-846 Test Methods for Evaluating SolidWaste, Physical/Chemical Methods31This test method is under the jurisdiction of AS
11、TM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved June 1, 2010. Published July 2010. DOI: 10.1520/D7644-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact AST
12、M Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from National Technical Information Service (NTIS), U.S. Depart-ment of Commerce, 5285 Port Royal Road, Springfield, VA, 22161 or at
13、http:/www.epa.gov/epawaste/hazard/testmethods/index.htm.TABLE 1 Detection Verification Level and Reporting RangeAnalyteDVL(ng/L)Reporting Range(ng/L)Bromadiolone 20 125-2500Brodifacoum 20 125-2500Diphacinone 20 125-2500Warfarin 20 125-25001Copyright ASTM International, 100 Barr Harbor Drive, PO Box
14、C700, West Conshohocken, PA 19428-2959, United States.FIG. 1 Example Primary SRM Chromatograms Signal/Noise RatiosFIG. 2 Example Confirmatory SRM Chromatograms Signal/Noise RatiosD7644 1023. Terminology3.1 Definitions:3.1.1 detection verification level, DVL, na concentrationthat has a signal/noise (
15、S/N) ratio greater than 3:1 and is at least3 times below the Reporting Limit (RL).3.1.2 reporting limit, RL, nthe concentration of thelowest-level calibration standard used for quantification ac-counting for the sample dilution.3.1.2.1 DiscussionIn this test method, a 40 mL samplealiquot is diluted
16、to a 50 mL final volume after thoroughlyrinsing the collection vial with methanol for quantitativetransfer. In this case, the lowest calibration level of 100 pptwould allow a reporting limit of 125 ppt to be achieved.3.1.3 rodenticides, nin this test method, bromadiolone,brodifacoum, diphacinone, an
17、d warfarin collectively.3.2 Abbreviations:3.2.1 mMmillimolar, 1 3 10-3moles/L3.2.2 NDnon-detect3.2.3 pptparts per trillion, ng/L4. Summary of Test Method4.1 This is a performance based method, and modificationsare allowed to improve performance.4.2 For rodenticide analysis, samples are shipped to th
18、e labbetween 0C and 6C and analyzed within 14 days of collec-tion. In the lab, the samples are spiked with surrogates,quantitatively transferred to a graduated cylinder using threemethanol rinses, filtered using a syringe driven filter unit, andanalyzed directly by LC/MS/MS.4.3 Bromadiolone, brodifa
19、coum, diphacinone, warfarin,warfarin-D5(surrogate) and 2-bromo-4-(1,1,3,3-tetramethylbutyl)phenol (brominated octylphenol, Br-OP, sur-rogate) are identified by retention time and two SRM transi-tions. The target analytes and surrogates are quantitated usingthe primary SRM transitions utilizing an ex
20、ternal calibration.The final report issued for each sample lists the concentrationof bromadiolone, brodifacoum, diphacinone, warfarin, andsurrogate recoveries.5. Significance and Use5.1 This test method has been developed in support of theNational Homeland Security Research Center, US EPA byRegion 5
21、 Chicago Regional Laboratory (CRL).5.2 Bromadiolone, brodifacoum, diphacinone and warfarinare rodenticides for controlling mice, rats, and other rodentsthat pose a threat to public health, critical habitats, native plantsand animals, crops, food and water supplies. These rodenti-cides also present h
22、uman and environmental safety concerns.Warfarin and diphacinone are first-generation anticoagulants,while bromadiolone and brodifacoum are second-generation.The anticoagulants interfere with blood clotting, and death canresult from excessive bleeding. The second-generation antico-agulants are especi
23、ally hazardous for several reasons. They arehighly toxic and persist a long time in body tissues. Thesecond-generation anticoagulants are designed to be toxic in asingle feeding, but time-to-death occurs in several days. Thisallows rodents to feed multiple times before death, leading tocarcasses con
24、taining residues that may be many times the lethaldose.45.3 This method has been investigated for use with reagent,surface, and drinking water for the selected rodenticides.6. Interferences6.1 Method interferences may be caused by contaminants insolvents, reagents, glassware and other apparatus prod
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD764420104375STANDARDTESTMETHODFORDETERMINATIONOFBROMADIOLONEBRODIFACOUMDIPHACINONEANDWARFARININWATERBYLIQUIDCHROMATOGRAPHYTANDEMMASSSPECTROMETRYLCMSMPDF

链接地址:http://www.mydoc123.com/p-526010.html