《ASTM D7634-2010 2500 Standard Test Method for Visualizing Particulate Sizes and Morphology of Particles Contained in Hydrogen Fuel by Microscopy《用显微镜法目视检测氢燃料中微粒的粒径和形态的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7634-2010 2500 Standard Test Method for Visualizing Particulate Sizes and Morphology of Particles Contained in Hydrogen Fuel by Microscopy《用显微镜法目视检测氢燃料中微粒的粒径和形态的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7634 10Standard Test Method forVisualizing Particulate Sizes and Morphology of ParticlesContained in Hydrogen Fuel by Microscopy1This standard is issued under the fixed designation D7634; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is primarily intended for visualizingand measuring the sizes and morph
3、ology of particulates inhydrogen used as a fuel for fuel cell or internal combustionengine powered vehicles. This test method describes proce-dures required to obtain size and morphology data of knownquality. This test method can be applied to other gaseoussamples requiring determination of particul
4、ate sizes and mor-phology provided the users data quality objectives are satis-fied.1.2 Mention of trade names in standard does not constituteendorsement or recommendation. Other manufacturers ofequipment, software or equipment models can be used.1.3 The values stated in SI units are to be regarded
5、asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine th
6、e applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D7650 Test Method for Test Method for Sampling ofParticulate Matter in High Pressure Hydrogen used as aGaseous Fuel with an In-Stream Filter2.2 SAE Standards:3SAE TIR J2719 Hydrogen Quality Guideline f
7、or Fuel CellVehicles, April 2008SAE J6000 Compressed Hydrogen Surface Vehicle Refu-eling Connection Devices3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 constituentcomponent (or compound) found withina hydrogen fuel mixture3.1.2 contaminantimpurity that adversely affects the
8、 com-ponents within the fuel cell system or the hydrogen storagesystem3.1.3 fuel cell grade hydrogenhydrogen satisfying thespecifications in SAE TIR J2719.3.1.4 gaseous fuelmaterial to be tested, as sampled, with-out change of composition by drying or otherwise.3.1.5 HEPA FilterA high efficiency par
9、ticulate air filterwhich, by definition, removes at least 99.97% of airborneparticles 0.3m in diameter.3.1.6 SAE TIR J2719Information Report on the develop-ment of a hydrogen quality guideline for fuel cell vehicles3.2 Acronyms:3.2.1 FCVFuel Cell Vehicle3.2.2 PSAParticulate sampling adapter for samp
10、ling par-ticulate in hydrogen fuel3.2.3 HQSAHydrogen quality sampling adapter for sam-pling gaseous hydrogen fuel3.2.4 SAESociety of Automotive Engineers International3.2.5 PEMPolymer Electrolyte Membrane, also calledProton Exchange Membrane3.2.6 PEMFCproton exchange membrane fuel cells4. Summary of
11、 Test Method4.1 This procedure is for visualizing and measuring, bymicroscopy, the sizes and morphology of particulates aftercollection of particulates contained within hydrogen fuel atfueling station dispenser nozzles (Test Method D7650, SAEJ2600) or other gaseous fuel delivery system dispenser int
12、er-faces. Every precaution should be taken to avoid contamination1This test method is under the jurisdiction ofASTM Committee D03 on GaseousFuels and is the direct responsibility of Subcommittee D03.14 on Hydrogen andFuel Cells.Current edition approved Dec. 1, 2010. Published February 2011. DOI: 10.
13、1520/D763410.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from SAE International (SAE), 400 Com
14、monwealth Dr., Warrendale,PA 15096-0001, http:/www.sae.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.of particulates onto the filter coming from the PSA, theanalytical system, ambient air, filter handling or other environ-menta
15、l sources.5. Significance and Use5.1 Low temperature fuel cells such as proton exchangemembrane fuel cells (PEMFCs) require high purity hydrogenfor maximum material performance and lifetime. The particu-lates in hydrogen used in FCVs and hydrogen powered internalcombustion vehicles may adversely aff
16、ect pneumatic controlcomponents, such as valves or other critical system compo-nents. The visualization of the size and morphology of particlesis an important tool for determining particle origin as well asfor devising particle formation reduction strategies.6. Interferences6.1 Particulate matter or
17、iginating in the environment orequipment will interfere with the determinations. Every pre-caution should be taken to avoid contamination of particulatesonto the filter coming from the analytical system, ambient air,filter handling, or other environmental sources.6.2 The potential effect of body moi
18、sture or oils contactingthe filters is minimized by using powder-free gloves whilehandling filters outside the glove box.7. Apparatus7.1 MicroscopeA microscopy system is necessary to havereflectance and transmittance illuminations, built-in polariza-tion system and a digital camera with an USB conne
19、ction to acomputer. The microscope is covered with a plastic cover whennot in use and placed on a table top inside a horizontal flowhood containing a HEPA filter (7.3).7.2 Mini-Clean RoomA small clean room with HEPAfilter should be used to store unused TFE-flourocarbon filters,filter holders, and sa
20、mpled filters at atmospheric moisture lessthan 30%.7.3 HEPA Filter Fitted Horizontal Flow HoodA flowhood that blows filtered air through a HEPA filter horizontally.This eliminates or reduces environmental particulates that caninterfere with microscope visualization. The air velocity mea-sured by Van
21、eometer (7.4) should be over 80 ft/minute (1.46km/hour); otherwise, an electronic air velocity meter (7.5)should alarm the operator.7.4 VaneometerThis metering device is used to measureair velocity passing through the HEPA Filter fitted HorizontalFlow Hood.7.5 Electronic Air Velocity MeterAn Electro
22、nic air veloc-ity meter is used to notify the analyst if the horizontal air flowbehind the microscope falls below approximately 80 ft perminute.7.6 HEPA VacuumA vacuum fitted with a HEPA filter isused to remove dust from the glove box or areas where filtersare stored or manipulated.8. Reagents and M
23、aterials8.1 FilterA 47 mm diameter polytetrafluoroethylene filter(PTFE Membrane Disc Filters) is used. An example of asuitable filter is a Pall TF-200 47mm 0.2 m (P/N 66143) witha pore size of 0.2 m. One side of this type filter is composedof polytetrafluoroethylene (PTFE) and the reverse side iscom
24、posed of polypropylene. Installed in the filter holder, thePTFE side should face the hydrogen fuel stream. The polypro-pylene side of the filter is generally shinier than the PTFE side,which is dull when viewed under a bright light. Whenexamining, visualizing, handling, and weighing filters, the sid
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD763420102500STANDARDTESTMETHODFORVISUALIZINGPARTICULATESIZESANDMORPHOLOGYOFPARTICLESCONTAINEDINHYDROGENFUELBYMICROSCOPY

链接地址:http://www.mydoc123.com/p-525992.html