ASTM D7599-2016(2017) 1250 Standard Test Method for Determination of Diethanolamine Triethanolamine N-Methyldiethanolamine and N-Ethyldiethanolamine in Water by Single Reaction Mon.pdf
《ASTM D7599-2016(2017) 1250 Standard Test Method for Determination of Diethanolamine Triethanolamine N-Methyldiethanolamine and N-Ethyldiethanolamine in Water by Single Reaction Mon.pdf》由会员分享,可在线阅读,更多相关《ASTM D7599-2016(2017) 1250 Standard Test Method for Determination of Diethanolamine Triethanolamine N-Methyldiethanolamine and N-Ethyldiethanolamine in Water by Single Reaction Mon.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7599 16 (Reapproved 2017)Standard Test Method forDetermination of Diethanolamine, Triethanolamine,N-Methyldiethanolamine and N-Ethyldiethanolamine in Waterby Single Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)1This standard is issued under the fixed des
2、ignation D7599; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision
3、 or reapproval.1. Scope1.1 This procedure covers the determination ofdiethanolamine, triethanolamine, N-methyldiethanolamine andN-ethyldiethanolamine (referred to collectively as ethano-lamines in this test method) in surface water by direct injectionusing liquid chromatography (LC) and detected wit
4、h tandemmass spectrometry (MS/MS). These analytes are qualitativelyand quantitatively determined by this test method. This testmethod adheres to single reaction monitoring (SRM) massspectrometry.1.2 This test method has been developed by U.S. EPARegion 5 Chicago Regional Laboratory (CRL).1.3 The val
5、ues stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 The Detection Verification Level (DVL) and ReportingRange for the ethanolamines are listed in Table 1.1.4.1 The DVL is required to be at a concentration at least3 times below the Repo
6、rting Limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 displays the signal/noiseratios at the DVLs and at higher concentrations forN-methyldiethanolamine.1.4.2 The reporting limit is the concentration of the Level 1calibration standard as shown in Table 2 for diethanolamine,triethan
7、olamine, and N-ethyldiethanolamine and Level 2 forN-methyldiethanolamine. The reporting limit forN-methyldiethanolamine is set at 50 g/L due to poor sensi-tivity at a 5 g/L concentration which did not meet the DVLcriteria. The DVL for N-methyldiethanolamine is at 10 g/L,which forces a raised reporti
8、ng limit (chromatograms areshown in Fig. 1). However, the multi-laboratory validationrequired a spike of all target analytes at 25 g/L. The meanrecovery for N-methyldiethanolamine at this level was 88 % asshown in Table 3. If your instruments sensitivity can meet therequirements in this test method,
9、 N-methyldiethanolamine mayhave a 25 g/L reporting limit.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bili
10、ty of regulatory limitations prior to use.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the Wor
11、ld Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3856 Guide fo
12、r Management Systems in LaboratoriesEngaged in Analysis of WaterD3694 Practices for Preparation of Sample Containers andfor Preservation of Organic ConstituentsD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE2554 Practice for Estimating and Monit
13、oring the Uncer-tainty of Test Results of a Test Method Using ControlChart Techniques1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved June 1
14、5, 2017. Published July 2017. Originallyapproved in 2009. Last previous edition approved in 2016 as D7599 16. DOI:10.1520/D7599-16R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume info
15、rmation, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardizat
16、ion established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.12.2 Other Documents:EPA publication SW-846 Test Methods for Evaluating SolidWaste, Physical/Chem
17、ical Methods33. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this standard, refer toTerminology D1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 detection verification level, DVL, na concentrationthat has a signal/noise ratio greater than 3:1 and is at least 3times
18、 below the reporting limit (RL).3.2.2 ethanolamines, nin this test method,diethanolamine, triethanolamine, N-methyldiethanolamine andN-ethyldiethanolamine collectively.3.2.3 independent reference material, IRM, na material ofknown purity and concentration obtained either from theNational Institute o
19、f Standards andTechnology (NIST) or otherreputable supplier. The IRM shall be obtained from a differentlot of material than is used for calibration.3.3 Acronyms:3.3.1 CCC, nContinuing Calibration Check3.3.2 IC, nInitial Calibration3.3.3 LC, nLiquid Chromatography3.3.4 LCS/LCSD, nLaboratory Control S
20、ample/Laboratory Control Sample Duplicate3.3.5 MDL, nMethod Detection Limit3.3.6 MeOH, nMethanol3.3.7 mM, nmillimolar,1103moles/L3.3.8 MRM, nMultiple Reaction Monitoring3.3.9 MS/MSD, nMatrix Spike/Matrix Spike Duplicate3.3.10 NA, adjNot Available3.3.11 ND, nnon-detect3.3.12 P (Diethanolamine-D8),whe
21、re the ethylene moieties contain all2H (CAS # 103691-51-6).8.12.1 Diethanolamine-D8is used as a surrogate in thisstandard.9. Hazards9.1 Normal laboratory safety applies to this method. Ana-lysts should wear safety glasses, gloves, and lab coats whenworking in the lab. Analysts should review the Safe
22、ty DataSheets (SDS) for all reagents used in this test method.10. Sampling10.1 SamplingGrab samples must be collected in 25-mLpre-cleaned amber glass bottles with Teflon-lined caps demon-strated to be free of interferences. This test method requires a25-mL sample size per analysis. Conventional samp
23、ling prac-tices should be followed. Refer to Guide D3856 and PracticesD3694.8AWaters Quattro (a trademark of the Waters Corporation, Milford, MA) microAPI mass spectrometer, or equivalent, was found suitable for use The multi-laboratory study included Applied Biosystems, Varian and Waters mass spect
24、rom-eters.9A Millex HV Syringe-Driven Filter Unit PVDF 0.45 m (MilliporeCorporation, Catalog # SLHV033NS; Millex is a trademark of Merck KGAA,Darmstadt, Germany) has been found suitable for use for this test method, any filterunit may be used that meets the performance of this test method may be use
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7599201620171250STANDARDTESTMETHODFORDETERMINATIONOFDIETHANOLAMINETRIETHANOLAMINENMETHYLDIETHANOLAMINEANDNETHYLDIETHANOLAMINEINWATERBYSINGLEREACTIONMONPDF

链接地址:http://www.mydoc123.com/p-525926.html