ASTM D7590-2009(2014) 9979 Standard Guide for Measurement of Remaining Primary Antioxidant Content In In-Service Industrial Lubricating Oils by Linear Sweep Voltammetry《使用线性扫描伏安法测量.pdf
《ASTM D7590-2009(2014) 9979 Standard Guide for Measurement of Remaining Primary Antioxidant Content In In-Service Industrial Lubricating Oils by Linear Sweep Voltammetry《使用线性扫描伏安法测量.pdf》由会员分享,可在线阅读,更多相关《ASTM D7590-2009(2014) 9979 Standard Guide for Measurement of Remaining Primary Antioxidant Content In In-Service Industrial Lubricating Oils by Linear Sweep Voltammetry《使用线性扫描伏安法测量.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7590 09 (Reapproved 2014)Standard Guide forMeasurement of Remaining Primary Antioxidant Content InIn-Service Industrial Lubricating Oils by Linear SweepVoltammetry1This standard is issued under the fixed designation D7590; the number immediately following the designation indicates the
2、year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONUnder normal thermal and oxidative working condition
3、s, which degrade the chemical compositionof the oils basestock and gradually deplete the oils additive package, good oil condition monitoringprocedures are necessary to determine and planning corrective actions before the oil propertieschanges have passed their warning limits. Antioxidant monitoring
4、 practices are a vital part of modernoil condition monitoring practices to achieve lubrication excellence. This guide addresses the correctguidelines for voltammetric data interpretation.1. Scope1.1 This guide covers the voltammetric analysis for quali-tative measurements of primary antioxidants in
5、new or in-service type industrial lubricants detectable in concentrationsas low as 0.0075 mass percent up to concentrations found innew oils by measuring the amount of current flow at a specifiedvoltage in the produced voltammogram.1.2 This guide can be used as a resource for a conditionmonitoring p
6、rogram to track the oxidative health of a range ofindustrial lubricants which contain primary antioxidants. Inorder to avoid excessive degradation of the base-oil, theseprimary antioxidants play a major role to protect the lubricantsagainst thermal-oxidative degradation. This guide can helpusers wit
7、h interpretation and troubleshooting results obtainedusing linear sweep voltammetry (LSV).1.3 When used as part of oil condition monitoring practices,it is important to apply trend analysis to monitor the antioxi-dant depletion rate relative to a baseline sample rather than usevoltammetry for an abs
8、olute measurement of the antioxidantconcentration. The trending pattern provides a proactive meansto identify the level of oil degradation or abnormal changes inthe condition of the in-service lubricant.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement ar
9、e included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations p
10、rior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4378 Practice for In-Service Monitoring of Mineral Tur-bine Oils for Steam, Gas, and Combined Cycle TurbinesD6224 Practice for In-Service
11、Monitoring of Lubricating Oilfor Auxiliary Power Plant EquipmentD6304 Test Method for Determination of Water in Petro-leum Products, Lubricating Oils, and Additives by Cou-lometric Karl Fischer TitrationD6810 Test Method for Measurement of Hindered PhenolicAntioxidant Content in Non-Zinc Turbine Oil
12、s by LinearSweep VoltammetryD6971 Test Method for Measurement of Hindered Phenolicand Aromatic Amine Antioxidant Content in Non-zincTurbine Oils by Linear Sweep VoltammetryD7214 Test Method for Determination of the Oxidation ofUsed Lubricants by FT-IR Using Peak Area IncreaseCalculation1This guide i
13、s under the jurisdiction of ASTM Committee D02 on PetroleumProducts, Liquid Fuels, and Lubricants and is the direct responsibility of Subcom-mittee D02.09.0C on Oxidation of Turbine Oils.Current edition approved May 1, 2014. Published July 2014. Originally approvedin 2009. Last previous edition appr
14、oved in 2009 as D7590 091. DOI: 10.1520/D7590-09R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright
15、 ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.2 ISO Standards:3ISO 4406.2 Hydraulic fluid powerFluidsMethod forcoding the level of contamination by solid particles2.3 Other Standards:4VGB Guideline VGB-M 416 M In-Service Monitoring ofTurbi
16、ne Oils3. Oil Condition Monitoring Programs3.1 Most industrial lubricants consist of mineral or syntheticoils compounded with oxidation and rust inhibitors. Dependingupon their application and the performance level desired,specific required amounts of other additives such as metaldeactivators, pour
17、depressants, extreme pressure additives, andfoam suppressants can also be present.3.2 With modern formulations of industrial lubricants, theantioxidants play a major role in protecting the base-oil againstexcessive degradation. To prevent this base-oil degradation,resulting in the eventual build-up
18、of deposits, varnish andsludge, the monitoring of the antioxidants represents a proac-tive information on the remaining oxidative health of thein-service lubricant. Oxidation is a chemical reaction betweenoxygen atoms with the base oil hydrocarbon molecules, whichare converting the hydrocarbon molec
19、ules into oxidation prod-ucts and subsequently weak organic acids. The rate of oxida-tion depends on the presence of antioxidant additives, whichcontrols the speed of oxidation, but eventually the antioxidantsare consumed. Consequently as part of modern proactivemaintenance strategies, it is vital t
20、o know at any time duringthe operating cycle of the lubricants, its condition by assessingthe remaining activity of antioxidants, to prevent the oxidativedegradation of the base oil.3.3 Antioxidant monitoring guidelines have been part ofInternational Standards such as Practice D4378, PracticeD6224,
21、and VGB Guideline VGB-M 416 M, as well Interna-tional OEM Maintenance Specifications. This guide presentsguidelines for the lubricant professionals using voltammetrictechniques as part of their regular maintenance strategies, suchas data interpretation, oil analysis frequency, combination withother
22、condition monitoring tests, etc.4. Summary of Linear Sweep Voltammetric (LSV) TestMethod4.1 Linear Sweep Voltammetric (LSV) test can be per-formed on any type of industrial lubricant containing at leastone type of antioxidant. The voltammetric test is a comparativetest method. By establishing a comp
23、arison between its refer-ence oil (fresh oil or standard) and its used oil, this guide canbe used without the specific knowledge on the category towhich the antioxidants belong.4.2 ASTM International has two standards, Test MethodD6810 and D6971, that shall enable the measurement of theremaining phe
24、nolic and aminic type of antioxidants. Nostandard test method has been developed for the detection ofother type of antioxidants by linear voltammetry, althoughLSV also has detection capabilities for these types of second-ary antioxidants (such as zinc dialkyl dithiophosphates).54.3 A measured quanti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7590200920149979STANDARDGUIDEFORMEASUREMENTOFREMAININGPRIMARYANTIOXIDANTCONTENTININSERVICEINDUSTRIALLUBRICATINGOILSBYLINEARSWEEPVOLTAMMETRY

链接地址:http://www.mydoc123.com/p-525898.html