ASTM D7571-2010 0625 Standard Specification for Retained Sewn Seam Strength After Exposures to Hot Air and Open Flame《测定缝制接缝在暴露于热空气和明火后保留的强度的标准规范》.pdf
《ASTM D7571-2010 0625 Standard Specification for Retained Sewn Seam Strength After Exposures to Hot Air and Open Flame《测定缝制接缝在暴露于热空气和明火后保留的强度的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7571-2010 0625 Standard Specification for Retained Sewn Seam Strength After Exposures to Hot Air and Open Flame《测定缝制接缝在暴露于热空气和明火后保留的强度的标准规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7571 10Standard Specification forRetained Sewn Seam Strength After Exposures to Hot Airand Open Flame1This standard is issued under the fixed designation D7571; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONSewn seam strength of flame resistant textile products is a critical measurement of structuralintegrity. This is p
3、articularly important for flame resistant (FR) personal protective clothing andequipment (PPE), which is designed to provide safety to any worker who may, during the service lifeof the PPE, experience multiple short term exposures to high heat. While “new” FR protective clothingitems can provide the
4、 wearer with protection that meets a specific performance requirement, it isuseful to know what the cumulative effects of repeated exposures to high heat can do to the integrityof the sewn seams used to construct protective clothing items. In addition, it is useful to know howthe cumulative exposure
5、s can affect the sewn seam strength performance of the PPE when exposed toan open flame for a short period of time.During normal use, some FR specialized clothing items can, for short durations, be repeatedlyexposed to high heat. While the cumulative effect of repeated short duration exposures to hi
6、gh heatis known to result in a loss of fabric strength, these same exposures can also result in a loss of sewingthread break strength. This loss of break strength can result in lower retained sewn seam strength thatcan put the wearer at potential risk of injury if the garment is too weak to maintain
7、 integrity of thestructure.While there are recognized minimum sewn seam strength values required for new FR garments,never exposed to heat or flame hazard, this standard is intended to measure the retained sewn seamstrength after repeated exposures to high heat and a subsequent exposure to open flam
8、e.These data may be useful as additional information for agencies that want criteria to establishselection, care, maintenance and retirement/replacement of FR protective clothing.1. Scope1.1 This specification covers the retained sewn seamstrength of flame resistant fabric subassemblies after repeat
9、edshort duration exposures to hot air or repeated short-durationexposures to hot air and subsequent short-term exposures toopen-flame impingement.1.1.1 This specification is used to determine minimumretained sewn seam strength after these exposures.1.2 This standard is not intended to serve as a det
10、ailedmanufacturing or purchasing specification, but can be refer-enced in purchase contracts to ensure that minimum perfor-mance requirements are met.1.3 Controlled laboratory tests used to determine compli-ance with the performance requirements of this standard shallnot be deemed as establishing pe
11、rformance levels for allsituations to which wearers of FR protective clothing arepotentially exposed.1.4 Mandatory requirements are indicated by use of shall;recommendations and advising information is indicated byshould.1.5 This standard is used to measure and describe theresponse of materials, pro
12、ducts, or assemblies to heat andflame under controlled conditions, but does not by itselfincorporate all factors required for fire hazard or fire riskassessment of the materials, products, or assemblies underactual fire conditions.1This specification is under the jurisdiction of ASTM Committee D13 o
13、nTextiles and is the direct responsibility of Subcommittee D13.52 on Flammability.Current edition approved May 1, 2010. Published June 2010. DOI: 10.1520/D7571-10.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.1.6 Fire testing is in
14、herently hazardous. Adequate safe-guards for personnel and property shall be employed inconducting these tests.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safe
15、ty and health practices, and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D123 Terminology Relating to TextilesD1683 Test Method for Failure in Sewn Seams of WovenApparel FabricsD1776 Practice for Conditioning and Testing TextilesD439
16、1 Terminology Relating to The Burning Behavior ofTextilesD6193 Practice for Stitches and SeamsD7016 Test Method to Evaluate Edge Binding ComponentsUsed in Mattresses After Exposure to An Open Flame2.2 AATCC Test Methods:3TM 135 Dimensional Changes of Fabrics after Home Laun-dering2.3 ISO Documents:4
17、ISO 17493 Clothing and Equipment for Protection AgainstHeat Test Method for Convective Heat Resistance Using aHot Air Circulating Oven3. Terminology3.1 The following terms are relevant to this standard:critical sewn seams, retained sewn seam strength (RSS50),seam engineering, sewn seam strength.3.2
18、For all terms related to flammability of textiles seeTerminology D4391.3.3 For all terminology related to textiles, see TerminologyD123.4. Significance and Use4.1 It is possible that the user of FR protective clothing willexperience repeated exposures to hot air as part of the workenvironment. While
19、 these individual exposures are likely not topose a catastrophic threat, the cumulative effect of theseexposures are likely to reduce the level of retained sewn seamstrength performance to a value that is measurably lower thanthe sewn seam strength performance requirement establishedfor a new item.4
20、.2 The assembly of textile structures requires that the seamengineering used to manufacture the product anticipate how toretain the maximum sewn seam strength during the anticipatedlife cycle of the product.4.2.1 Initial sewn seam strength performance requirementsof FR textile products measures sewn
21、 seam strength of a new(never exposed to heat environment) product.4.2.2 Retained sewn seam strength (RSS50) can be used tomeasure seam failure of FR protective clothing after repeatedshort duration exposures to high heat. RSS50can also be usedto measure seam failure of FR protective clothing whenex
22、posed to open flame after repeated short duration exposuresto high heat.4.3 These data about retained sewn seam strength are usefulto establish criteria to determine when to repair, retire, orreplace FR protective clothing.5. Materials and Manufacture5.1 Sewn seam assembly samples for testing shall
23、be madeusing seams and stitches described in Practice D6193 andconstructed with inherently flame resistant sewing thread.5.2 Purchaser and supplier shall agree on the number ofspecimens to be tested. As a minimum, five specimens of eachconstruction shall be tested.5.3 For details about samples and c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD757120100625STANDARDSPECIFICATIONFORRETAINEDSEWNSEAMSTRENGTHAFTEREXPOSURESTOHOTAIRANDOPENFLAME 测定

链接地址:http://www.mydoc123.com/p-525844.html