《ASTM D7519-2011 6250 Standard Test Method for Internal Bond Strength and Thickness Swell of Cellulosic-Based Fiber and Particle Panels After Repeated Wetting《反复浸湿后的纤维板和颗粒板的内部粘结强度和厚.pdf》由会员分享,可在线阅读,更多相关《ASTM D7519-2011 6250 Standard Test Method for Internal Bond Strength and Thickness Swell of Cellulosic-Based Fiber and Particle Panels After Repeated Wetting《反复浸湿后的纤维板和颗粒板的内部粘结强度和厚.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7519 11Standard Test Method forInternal Bond Strength and Thickness Swell of Cellulosic-Based Fiber and Particle Panels After Repeated Wetting1This standard is issued under the fixed designation D7519; the number immediately following the designation indicates the year oforiginal adopt
2、ion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods provide a measure of the moistureresistance of cellulo
3、sic-based fiber and particle panels (forexample, medium-density fiberboard (MDF), particleboard,and hardboard). Resistance to moisture changes is measured bydimensional and internal bond changes and does not refer todecay/mold resistance or other performance aspects.1.2 These test methods do not add
4、ress structural propertiesor performance following moisture exposure. Panels are sub-jected to repeated cycles of water submersion and oven drying.After three cycles, the test specimens are tested for thicknessswelling (TS) and internal bond (IB) strength.1.3 The values stated in inch-pound units ar
5、e to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility
6、 of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1037 Test Methods for Evaluating Properties of Wood-Base Fiber and Particle Panel MaterialsD4442 Tes
7、t Methods for Direct Moisture Content Measure-ment of Wood and Wood-Base MaterialsD4933 Guide for Moisture Conditioning of Wood andWood-Based Materials3. Significance and Use3.1 These test methods provide a measure of the moistureresistance of cellulosic-based fiber and particle panels (forexample,
8、medium-density fiberboard (MDF), particleboard,and hardboard). This test methodology can be used to assessthe thickness swelling and bond integrity characteristics ofpanels engineered for interior end-use applications involvingexposure to cyclic temperatures and intermittent wetting envi-ronments.4.
9、 Apparatus4.1 The methods and test equipment used in Test MethodsD1037 are used in these test methods.5. Sampling and Test Specimens5.1 Two samples taken from the same board measuring 6 36 in. (152 3 152 mm) shall be used for collection of thicknessswelling (TS) data.5.2 Three internal bond (IB) str
10、ips measuring 6 3 12 in.(152 3 305 mm) shall be cut from the same board as the TSsamples.6. Conditioning6.1 Condition specimens to practical equilibrium at a rela-tive humidity of 65 6 3 % and a temperature of 68 6 4F (206 2C). Practical equilibrium is defined as the state of timechange in which, fo
11、r practical purposes, the specimen is neithergaining nor losing appreciable moisture content in a 24-hperiod. Guide D4933 provides further information on moistureequilibrium.7. Procedure7.1 Thickness Swell (TS)7.1.1 After conditioning, the mass of the specimen shall bemeasured to an accuracy of 60.2
12、 %. The width, length, andthickness of the specimen shall be measured to an accuracy of60.3 % to compute the volume of the specimen.7.1.2 The thickness shall be measured at four points mid-way along each side 1 in. (25 mm) away from the edge and theaverage of these four measurements shall be recorde
13、d as theinitial thickness for each specimen. The thickness shall bemeasured over a surface with14-in. diameter on both sides ofthe specimen using a micrometer with14-in. (6.4-mm) anvils.7.1.3 The specimens shall be submitted to three exposurecycles according to 7.2. The water soak tank parameters sh
14、allconform to the requirements of paragraph 23.5.1 of Test1This test method is under the jurisdiction of ASTM Committee D07 on Woodand is the direct responsibility of Subcommittee D07.03 on Panel Products.Current edition approved May 1, 2011. Published June 2011. DOI: 10.1520/D751911.2For referenced
15、 ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Cons
16、hohocken, PA 19428-2959, United States.Methods D1037. For drying, a forced air drying oven shall beused with an adequate internal volume to allow TS specimensto dry without being dead stacked.7.1.4 After the third exposure cycle, remove excess waterfrom the specimens using a paper towel and measure
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD751920116250STANDARDTESTMETHODFORINTERNALBONDSTRENGTHANDTHICKNESSSWELLOFCELLULOSICBASEDFIBERANDPARTICLEPANELSAFTERREPEATEDWETTING

链接地址:http://www.mydoc123.com/p-525719.html