《ASTM D7482-2015 4624 Standard Practice for Sampling Storage and Handling of Hydrocarbons for Mercury Analysis《汞分析用碳氢化合物的取样 存储以及处理的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7482-2015 4624 Standard Practice for Sampling Storage and Handling of Hydrocarbons for Mercury Analysis《汞分析用碳氢化合物的取样 存储以及处理的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7482 15Standard Practice forSampling, Storage, and Handling of Hydrocarbons forMercury Analysis1This standard is issued under the fixed designation D7482; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers the types of and preparation ofcontainers found most suitable for the handling of hydrocarbonsampl
3、es for the determination of total mercury.1.2 This practice was developed for sampling streams wherethe mercury speciation is predominantly Hg(0) present as amixture of dissolved Hg(0) atoms, adsorbed Hg(0) on particu-lates (for example, carbonaceous or mineral fines and Fe2O3)and suspended droplets
4、 of metallic mercury.1.3 The presence of suspended droplets of metallic mercury(often called “colloidal” mercury, since the droplet size can bevery small) can make obtaining a representative sample verydifficult for a variety of reasons (for example, non-isokineticsampling of the liquid can result i
5、n over- or under-collection ofsuspended droplets and collection of mercury that has accu-mulated in dense larger drops and pools on the bottom ofpiping and in sample taps). Pay strict attention to the detailedprocedure (Section 7) to ensure representative samples arecollected.1.4 When representative
6、 test portions are collected andanalyzed in accordance with acceptable procedures, the totalmercury is representative of concentrations in the sample.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 WarningMercury has bee
7、n designated by EPA andmany state agencies as a hazardous material that can causecentral nervous system, kidney, and liver damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury-containing products. See the applica
8、ble product Ma-terial Safety Data Sheet (MSDS) for details and EPAs website(http:/www.epa.gov/mercury/faq.htm) for additional informa-tion. Users should be aware that selling mercury or mercury-containing products, or both, in your state may be prohibited bystate law.1.7 This standard does not purpo
9、rt to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D417
10、5 Terminology Relating to Petroleum, PetroleumProducts, and LubricantsD7622 Test Method for Total Mercury in Crude Oil UsingCombustion and Direct Cold Vapor Atomic AbsorptionMethod with Zeeman Background CorrectionD7623 Test Method for Total Mercury in Crude Oil UsingCombustion-Gold Amalgamation and
11、 Cold Vapor AtomicAbsorption Method2.2 EPA Standard:3EPA Method 1669 Sampling Ambient Water for Trace Met-als at EPA Water Quality Criteria Levels; July 1996; USEnvironmental Protection Agency3. Terminology3.1 DefinitionsFor definitions of terms used in thisstandard, refer to Terminology D4175.3.2 A
12、bbreviations:3.2.1 VOAVolatile Organic Analysis4. Summary of Practice4.1 This practice describes the sampling, storage, transport,and handling of hydrocarbon samples used for determiningmercury, and the precautions that need to be taken to preventsample contamination and loss of analyte.1This practi
13、ce is under the jurisdiction of ASTM Committee D02 on PetroleumProducts, Liquid Fuels, and Lubricants and is the direct responsibility of Subcom-mittee D02.03 on Elemental Analysis.Current edition approved Nov. 1, 2015. Published November 2015. Originallyapproved in 2008. Last previous edition appro
14、ved in 2014 as D7482 14. DOI:10.1520/D7482-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from
15、 United States Environmental Protection Agency (EPA), ArielRios Bldg., 1200 Pennsylvania Ave., NW, Washington, DC 20460 (www.epa.gov).*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. U
16、nited States15. Significance and Use5.1 This practice is intended for use in sampling liquidhydrocarbons including crude oils, condensates, refinery pro-cess intermediates, and refined products. Generally thesesamples are expected to contain mercury from the parts perbillion (10-9mass) to parts per
17、million (10-6mass) range.5.2 This practice is not intended for use when samplingaqueous systems where the concentrations of mercury are oftenin the parts per trillion (10-12mass) range. These samples areoften better addressed by using the rigorously clean techniquesfrom the EPA Method 1669 “clean ha
18、nds, dirty hands” sam-pling procedures.5.3 This practice is not intended for use for liquefiedsamples, for which special containers may be required forpressurized samples.5.4 This practice is only suitable for stabilized sampleswhich remain 100 % liquid at ambient conditions. For samplesthat on depr
19、essurization lose some of the light hydrocarbonends it is important to note that elemental mercury may be lostduring sampling. Sampling modules which inject unstabilizedliquid hydrocarbons close to process conditions directly to themercury analyzer can be used to overcome this issue.5.5 Based on thi
20、s practice, two Test Methods (D7622 andD7623) are available for determination of mercury in crude oil,based on cold vapor atomic absorption technique.5.6 In some refined streams and in tank samples free watermay be present. Process streams that are water saturated maycondense water as the sample coo
21、ls from process temperatureto ambient temperature. Ionic mercury species are watersoluble and these water droplets may contain mercury oradsorb mercury over time.5.7 The presence of mercury during crude oil production,transport, and refining can be an environmental and industrialhygiene concern.6. A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD748220154624STANDARDPRACTICEFORSAMPLINGSTORAGEANDHANDLINGOFHYDROCARBONSFORMERCURYANALYSIS 分析 碳氢化合物

链接地址:http://www.mydoc123.com/p-525615.html