ASTM D7425 D7425M-2013 red 6626 Standard Specification for Spray Polyurethane Foam Used for Roofing Applications《屋顶用喷射聚氨酯泡沫的标准规范》.pdf
《ASTM D7425 D7425M-2013 red 6626 Standard Specification for Spray Polyurethane Foam Used for Roofing Applications《屋顶用喷射聚氨酯泡沫的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7425 D7425M-2013 red 6626 Standard Specification for Spray Polyurethane Foam Used for Roofing Applications《屋顶用喷射聚氨酯泡沫的标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7425/D7425M 11D7425/D7425M 13Standard Specification forSpray Polyurethane Foam Used for Roofing Applications1This standard is issued under the fixed designation D7425/D7425M; the number immediately following the designation indicates theyear of original adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the types and physical properties of spray polyurethane foam (SPF) for use
3、 in SPF roofingapplications.1.2 This specification does not provide guidance for application.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used inde
4、pendently of the other. Combining values from thetwo systems may result in non-conformance with the standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety
5、 and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C165 Test Method for Measuring Compressive Properties of Thermal InsulationsC168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flu
6、x Measurements and Thermal Transmission Properties by Means of theGuarded-Hot-Plate ApparatusC518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter ApparatusC1363 Test Method for Thermal Performance of Building Materials and EnvelopeAssemblies by Means of a
7、 Hot BoxApparatusD1079 Terminology Relating to Roofing and WaterproofingD1621 Test Method for Compressive Properties of Rigid Cellular PlasticsD1622 Test Method for Apparent Density of Rigid Cellular PlasticsD1623 Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular PlasticsD212
8、6 Test Method for Response of Rigid Cellular Plastics to Thermal and Humid AgingD2842 Test Method for Water Absorption of Rigid Cellular PlasticsD6226 Test Method for Open Cell Content of Rigid Cellular PlasticsE96/E96M Test Methods for Water Vapor Transmission of Materials3. Terminology3.1 Definiti
9、onsFor definitions of terms used in this specification, refer to Terminologies D1079 and C168.3.1.1 knit linealso called lift line. They are interchangeable terms describing the adhesion plane where one pass is sprayedover another.4. Significance and Use4.1 This specification covers spray polyuretha
10、ne foam (SPF) that is used as part of a SPF roofing system.1 This specification is under the jurisdiction of ASTM Committee D08 on Roofing and Waterproofing and is the direct responsibility of Subcommittee D08.06 on SprayPolyurethane Foam Roof Systems.Current edition approved Jan. 1, 2011Aug. 1, 201
11、3. Published February 2011August 2013. Originally approved in 2008. Last previous edition approved in 20082011 asD7425 08.D7425 11. DOI: 10.1520/D7425_D7425M-11.10.1520/D7425_D7425M-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm
12、.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
13、it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr
14、 Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Classification5.1 This specification covers SPF currently commercially available as described by the physical property requirements in Table1.5.2 SPF shall be manufactured with HFC, hydrocarbon or/and water blowing agents
15、. It is classified into two types as follows:5.2.1 Type IThermal resistance, R value, is equal to or greater than 0.98 Km2/W 5.6Fft2h/Btu per 25.4 mm 1 in.thickness.5.2.2 Type IIThermal resistance, R value, is between 0.72 and 0.98 Km2/W 4.1 and 5.6Fft2h/Btu per 25.4 mm 1 in.thickness.6. Ordering In
16、formation6.1 Orders for materials purchased under this specification shall include the following:6.1.1 ASTM designation, year of issue, and title.6.1.2 Type (see Type.5.2).6.1.3 Sampling, if different (see Section 9).6.1.4 If packaging is other than specified (see 13.1).6.1.5 If marking is other tha
17、n specified (see 13.4).7. Materials and Manufacture7.1 SPF is produced by the catalyzed polymerization of polyisocyanates in the presence of polyhydroxyl compounds, with theaddition of other compounds such as stabilizers and blowing agents.7.2 The materials shall be capable of being mixed and applie
18、d using commercially available polyurethane spray equipment.8. Physical Requirements8.1 SPF used in roofing applications shall meet the minimum physical property values as shown in Table 1.8.2 Other physical properties may be required, as agreed upon by the purchaser and the manufacturer.9. Sampling
19、9.1 Sampling for inspection tests, if required, shall be for properties agreed upon between the manufacturer and the purchaser.10. Test Specimen Preparation10.1 Finished SPF test panels shall be made by spray application consistent with the manufacturers recommendations includingtemperatures of the
20、liquid components, ambient temperature, temperature and type of substrate, type and operation settings of sprayequipment, and thickness of SPF per pass. Unless otherwise specified and reported, the ambient and substrate temperature shallbe 24 6 3C 75 6 5F and relative humidity must not exceed 80 %.
21、The test panels shall be of a sufficient quantity and size tosatisfy test requirements.10.2 The test panels shall be allowed to cure for at least 72 h at 24 6 3C 75 6 5F and 50 6 5 % relative humidity beforecutting or testing for additional physical properties.10.3 Core specimens, when required, sha
22、ll be obtained by removing both the external skin and the boundary skin found at thesubstrate/SPF interface. A trim cut on each face to a depth of 3 to 6 mm 18 to 14 in. is sufficientTABLE 1 Physical PropertyCOLSPEC/colnum=“3“ colname=“COLSPEC1“Property Units RequirementsProperty Units RequirementsT
23、hermal resistance of 25 mm 1.0 in. thickness agedatmean temperature 24C 75F and 180 daysKm2/W Fft2h/Btu 0.98 5.6, minThermal resistance of 25 mm 1.0 in. thickness agedat mean temperature 24C 75F for 180 days or atmean temperature 60C 140F for 90 days.Km2/W Fft 2h/Btu 0.98 5.6, minCompressive strengt
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7425D7425M2013RED6626STANDARDSPECIFICATIONFORSPRAYPOLYURETHANEFOAMUSEDFORROOFINGAPPLICATIONS 屋顶

链接地址:http://www.mydoc123.com/p-525438.html