《ASTM D7423-2009(2014) 8912 Standard Test Method for Determination of Oxygenates in C2 C3 C4 and C5 Hydrocarbon Matrices by Gas Chromatography and Flame Ionization Detection《使用气相色谱法.pdf》由会员分享,可在线阅读,更多相关《ASTM D7423-2009(2014) 8912 Standard Test Method for Determination of Oxygenates in C2 C3 C4 and C5 Hydrocarbon Matrices by Gas Chromatography and Flame Ionization Detection《使用气相色谱法.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7423 09 (Reapproved 2014)Standard Test Method forDetermination of Oxygenates in C2, C3, C4, and C5Hydrocarbon Matrices by Gas Chromatography and FlameIonization Detection1This standard is issued under the fixed designation D7423; the number immediately following the designation indicat
2、es the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the gas chromatograph
3、ic pro-cedure for the quantitative determination of organic oxygenatesin C2, C3, C4, and C5 matrices by multidimensional gaschromatography and flame ionization detection. This testmethod is applicable when the hydrocarbon matrices have afinal boiling point not greater than 200C. Oxygenate com-pounds
4、 include, but are not limited to, those listed in Table 1.The linear working range for oxygenates is 0.50 mg/kg to 100mg/kg.1.2 This test method is intended to determine the massconcentration of each oxygenate in the hydrocarbon matrix.Oxygenate compound identification is determined by referencestan
5、dards and column elution retention order.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of th
6、e user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1265 Practice for Sampling Liquefied Petroleum (LP)Gases, Manual MethodD1835 Specification for Liquefied P
7、etroleum (LP) GasesD4175 Terminology Relating to Petroleum, PetroleumProducts, and LubricantsD6299 Practice for Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6849 Practice for Storage and Use of Liquefied PetroleumGases (LP
8、G) in Sample Cylinders for LPG Test MethodsE355 Practice for Gas Chromatography Terms and Relation-ships3. Terminology3.1 Additional terminology related to the practice of gaschromatography can be found in Practice E355.3.2 Definitions:3.2.1 liquefied petroleum gas (LPG), na mixture of nor-mally gas
9、eous hydrocarbons, predominantly propane orbutane, or both, that has been liquefied by compression orcooling, or both, to facilitate storage, transport, and handling.D41753.2.2 oxygenate, nan oxygen-containing ashless organiccompound, such as an alcohol or ether, which may be used asa fuel or fuel s
10、upplement. D41753.3 Definitions of Terms Specific to This Standard:3.3.1 Deans switching methodrepresentative aliquot ofsample is injected on-column using a sample valve (or via a gaschromatograph split inlet). The sample passes onto a nonpolarcolumn, which elutes the lighter hydrocarbons in boiling
11、 pointorder to the analytical column and backflushes the heavierhydrocarbons to vent. The oxygenate compounds elute fromthe analytical column and are detected via a flame ionizationdetector.3.3.2 Deans switching method direct injectgas chromato-graphic valve configuration equipped with a valve conne
12、cteddirectly to the precolumn. This technique is commonly used forthe determination of oxygenates in ethene and propene con-centrates. This configuration provides the lowest detectionlimits such as those commonly required for ethene and propeneconcentrates.3.3.3 Deans switching method equipped with
13、a split inletgas chromatographic valve configuration equipped with a gaschromatograph split inlet for sample introduction into theprecolumn. This configuration is commonly used for the1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants
14、 and is the direct responsibility ofSubcommittee D02.D0.04 on C4 Hydrocarbons.Current edition approved May 1, 2014. Published July 2014. Originally approvedin 2009. Last pervious edition approved in 2009 as D7423 09. DOI: 10.1520/D7423-09R14.2For referenced ASTM standards, visit the ASTM website, ww
15、w.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1deter
16、mination of oxygenates in C5 hydrocarbon mixtures. Thistechnique using this configuration might not provide thedetection limits noted in the scope of this test method. If lowerdetection limits are required, then the user should considerusing the on-column valve direct injection technique.3.3.4 valve
17、 cut methodcommonly used for the determina-tion of oxygenates in C4 hydrocarbon mixtures. This techniqueusing a split inlet might not provide the detection limits notedin the scope of this test method. If lower detection limits arerequired, then the user should consider using the on-columnvalve dire
18、ct injection technique.3.3.5 valve cut method equipped with a split inletrepresentative aliquot of sample is injected via a gas chromato-graph split inlet for sample introduction into the precolumn.The sample passes onto a nonpolar column, which elutes thelighter hydrocarbons in boiling point order
19、to the analyticalcolumn and the heavier hydrocarbons to vent. The oxygenatecompounds elute from the analytical column and are detectedvia a flame ionization detector.3.4 Acronyms:3.4.1 DIPEdiisopropylether.3.4.2 ETBEethyl tert-butylether.3.4.3 MEK2-butanone.3.4.4 MTBEmethyl tert-butylether.3.4.5 TAM
20、Etert-amyl methylether.3.4.6 PLOTporous layer open tubular capillary column.3.4.7 WCOTwall coated open tubular capillary column.4. Summary of Test Method4.1 This test method shall be configured using either theDeans switching method or the valve cut method. Eachmethod shall be configured using an on
21、-column valve directinject technique or a gas chromatograph split inlet. Theon-column valve direct inject technique is configured byconnecting the head of the precolumn directly to the injectionvalve.4.2 The detector response and retention times for eachoxygenate peak in a calibration standard is me
22、asured and usedto externally calibrate the flame ionization detector response.The concentration of each oxygenate is calculated by theexternal standard technique. Calibration materials are listed inTable 1.5. Significance and Use5.1 The determination of oxygenates is important in themanufacture of e
23、thene, propene, 1-3 butadiene, C4hydrocarbons, and C5 hydrocarbons. Alcohols, ethers,aldehydes, and ketones are trace impurities in these hydrocar-bons. Oxygenates decrease catalyst activity in downstreampolymerization processes.6. Apparatus6.1 Gas ChromatographAny gas chromatographequipped with a f
24、lame ionization detector (FID) and havingsensitivity of 0.01 mg/kg. The gas chromatograph must becapable of linear temperature control from 50 to 320C for thecapillary column oven. The gas chromatograph must be ca-pable of controlling multiple valve events. Carrier gas flowcontrollers and or electro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7423200920148912STANDARDTESTMETHODFORDETERMINATIONOFOXYGENATESINC2C3C4ANDC5HYDROCARBONMATRICESBYGASCHROMATOGRAPHYANDFLAMEIONIZATIONDETECTION

链接地址:http://www.mydoc123.com/p-525432.html