ASTM D7358-2007 781 Standard Test Method for Water Content of Paints by Quantitative Calcium Hydride Reaction Test Kit《使用定量氢化钙反应试验盒测定水含量的标准试验方法》.pdf
《ASTM D7358-2007 781 Standard Test Method for Water Content of Paints by Quantitative Calcium Hydride Reaction Test Kit《使用定量氢化钙反应试验盒测定水含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7358-2007 781 Standard Test Method for Water Content of Paints by Quantitative Calcium Hydride Reaction Test Kit《使用定量氢化钙反应试验盒测定水含量的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7358 07Standard Test Method forWater Content of Paints by Quantitative Calcium HydrideReaction Test Kit1This standard is issued under the fixed designation D 7358; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the determination of the totalwater content of paints using a calcium hydride reac
3、tion testkit, or water content between 2 and 85 % water.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresp
4、onsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterD 3925 Practice for Sampling Liquid Paints and Relate
5、dPigmented CoatingsD 4017 Test Method for Water in Paints and Paint Materialsby Karl Fischer MethodE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with Specifications3. Summary of Test Method3.1 A0.25 mL sample is reacted with a specially formulatedcalcium hydride reag
6、ent to convert water in the sample tohydrogen gas. The reaction is carried out in a sealed pressurevessel and the resulting pressure is then measured using aspecially designed meter programmed to convert gas pressureinto water content. The results are displayed in milligrams ofwater in the reacted s
7、ample extract. The actual weight percentwater in the whole paint sample is manually calculated usingthe exact weights of the paint sample and the diluted extractsample, if used.4. Significance and Use4.1 Although Test Method D 4017 is widely used for thedetermination of water in paints and related m
8、aterials, thismethod may overcome some of the variability found in theKarl Fischer method.4.2 Control of water content is often important in control-ling the performance of paints, and it is critical in determiningvolatile organic compound (VOC) content when VOC contentis measured by difference from
9、 total volatile matter and watercontent as required in certain federal and state regulations.5. Interferences5.1 The following compounds, tested at twice the samplesize, have been found to produce no measurable response to thecalcium hydride reaction test kit and, therefore, cause nointerference at
10、levels up to 40 %:3EthanolMethanolAcetoneAMethyl Ethyl KetoneTetrahydrofuranDiethylene Glycol Dimethyl EtherEthylene GlycolADiethylene GlycolDipropylene GlycolStearic Acid2Ethyl Hexanoic AcidLead Oxide (II and III)Aluminum Oxide (Brockman I)A0.25 mL sample size program A and B.5.2 When using the 5 m
11、L sample size programs, that is,programs C, D, or E, ethylene glycol and acids have beenfound to produce a positive result in the presence of a small1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsib
12、ility ofSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved Nov. 1, 2007. Published November 2007.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards vol
13、ume information, refer to the standards Document Summary page onthe ASTM website.3HydroSCOUT Users Manual.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.amount of water. Ethylene glycol responds at approximately7 % of the volumetric
14、 equivalent.6. Apparatus6.1 HydroSCOUT4SystemA test kit system consisting ofthe HydroSCOUT meter, reaction tubes, sampling syringes anddilution vials.5The entire analytical sequence, including sam-pling, sample dilution, chemical reactions and quantification, isavailable in kit form using pre-dispen
15、sed and encapsulatedreagents. An analytical balance is required in order to obtainthe most precise results. In addition, a mechanical shaker maybe necessary to obtain a representative sample.7. Reagents and Materials7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests.All reagents
16、 shall conform to the specificationsof the Committee on Analytical reagents of the AmericanChemical Society, where such specifications are available.67.2 Purity of WaterUnless otherwise indicated, referenceto water shall mean reagent water conforming to SpecificationD 1193, Type II.7.3 Calcium Hydri
17、de (20 %) in HI SOL 10contained in acrushable glass ampule.7.4 Watercontained in a crushable glass ampule.7.5 Diethylene Glycol Dimethyl Ether (Diglyme)2.25 mLcontained in a glass vial.8. Hazards8.1 Store ampules in a cool, dry place. Keep away fromheat, sparks, water and open flames.8.2 See manufac
18、turers instructions and Material SafetyData Sheet (MSDS) before use.8.3 The gray ampule in the tube contains calcium hydride,which is a flammable solid and water reactive.8.4 Perform test only in a well ventilated area.8.5 Always wear rubber gloves and safety glasses.8.6 Take care to ensure that fin
19、gers are not cut by glass inthe kits. Each ampule should be crushed only once to reducethe risk of glass pieces piercing the sides of the tube.8.7 When venting reaction tube after completion of test,point tube upright and away from user and bystander.8.8 When breaking the green water ampule after co
20、mpletionof test, the tube must be shaken vigorously for the full 15seconds to ensure that the water contacting the remainingcalcium hydride does not overheat the side of the tube,otherwise tube failure can result.9. Sampling, Test Specimens, and Test Units9.1 Sample CollectionTake a representative s
21、ample of theliquid coatings in accordance with Practice D 3925. Mixthoroughly before taking specimens for individual tests.10. Preparation10.1 PreparationRemove a sampling syringe with capand a test tube from the kit box. Check the contents to ensurethat all items are present and intact. If a diluti
22、on is to be used,remove a dilution vial and an additional sampling syringe andcap. Remove the screw cap and rubber septum from the tubeand the cap from the dilution vial, if used. Insert one greenwater ampule into the top of the polypropylene ampule sleeveand replace the holder in the tube.11. Calib
23、ration and Standardization11.1 The commercially available meter is calibrated at thefactory over the pressure range of 0 to 60 psig. Each time themeter is turned on, the pressure transducer recalibrates the 0psig point. If this changes significantly from the factory setpoint, an error message will b
24、e displayed. This error will alsoappear if a tube is accidentally inserted into the meter beforethe meter is turned on.12. Procedure12.1 Sample Introduction for Expected Water Content LessThan 15 % (No Dilution)Work the plunger on an emptysampling syringe a few times to ensure that it slides easily.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD73582007781STANDARDTESTMETHODFORWATERCONTENTOFPAINTSBYQUANTITATIVECALCIUMHYDRIDEREACTIONTESTKIT

链接地址:http://www.mydoc123.com/p-525263.html