ASTM D7329-2007 752 Standard Specification for Food Preparation and Food Handling (Food Service) Gloves《食品制备和食品加工(食品服务)手套的标准规范》.pdf
《ASTM D7329-2007 752 Standard Specification for Food Preparation and Food Handling (Food Service) Gloves《食品制备和食品加工(食品服务)手套的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7329-2007 752 Standard Specification for Food Preparation and Food Handling (Food Service) Gloves《食品制备和食品加工(食品服务)手套的标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7329 07Standard Specification forFood Preparation and Food Handling (Food Service)Gloves1This standard is issued under the fixed designation D 7329; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the properties necessary forthin film, unlined polymer gloves to be used in food prepara-tion and
3、food handling.1.2 This specification is intended to serve as a referee and aguide to permit obtaining gloves of a consistent performance.The safe and proper use of gloves is excluded from the scopeof this specification.1.3 This standard does not purport to address all of thesafety concerns, if any,
4、associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 412 Test Methods for Vulcanized Rubber and Thermo-p
5、lastic ElastomersTensionD 573 Test Method for RubberDeterioration in an AirOvenD 882 Test Method for Tensile Properties of Thin PlasticSheetingD 3578 Specification for Rubber Examination GlovesD 3767 Practice for RubberMeasurement of DimensionsD 4679 Specification for Rubber General Purpose, House-h
6、old or Beautician GlovesD 5151 Test Method for Detection of Holes in MedicalGlovesD 5250 Specification for Poly(vinyl chloride) Gloves forMedical ApplicationD 5712 Test Method for Analysis of Aqueous ExtractableProtein in Natural Rubber and Its Products Using theModified Lowry MethodD 6124 Test Meth
7、od for Residual Powder on MedicalGlovesD 6319 Specification for Nitrile Examination Gloves forMedical ApplicationD 6499 Test Method for The Immunological Measurementof Antigenic Protein in Natural Rubber and its ProductsD 7246 Test Method for Detection of Holes in PolyethyleneFood Service Gloves2.2
8、ISO Standard:ISO 2859-1 Sampling Procedures and Tables for Inspectionby Attributes32.3 Code of Federal RegulationsTitle 21Food andDrugs:21 CFR Parts 17019943. Materials and Manufacture3.1 Any material or composition that permits the glove tomeet the specification identified by this standard and comp
9、lywith the requirements of this specification and the regulationspromulgated by the U.S. Food and Drug Administrationconcerning the materials used and permitted for direct foodcontact and the regulations concerning any powder or lubri-cants added to the gloves are acceptable.4. Performance Requireme
10、nts4.1 Gloves shall be sampled in accordance with the AQLspecified in Table 1 using a sampling plan derived fromISO 2859-1 or its equivalent, or other suitable statisticalrationale.4.2 Gloves shall be tested for freedom of holes as describedin 5.1 and comply with the requirements of Table 1 for free
11、domfrom holes.4.3 Gloves shall meet and be tested for dimensions andtolerances as described in 5.2 and comply with the perfor-mance requirements listed in Table 1 for dimensions.1This specification is under the jurisdiction ofASTM Committee D11 on Rubberand is the direct responsibility of Subcommitt
12、ee D11.40 on Consumer RubberProducts.Current edition approved Nov. 1, 2007. Published December 2007.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Do
13、cument Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 204
14、01, http:/www.access.gpo.gov.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Copyright by ASTM Intl (all rights reserved); Mon Apr 27 01:50:33 EDT 2009Downloaded/printed byGuo Dehua (CNIS) pursuant to License Agreement. No further re
15、productions authorized.4.4 Gloves shall meet and be tested for physical propertiesas described in 5.3 and comply with the performance require-ments listed in Table 1 for physical properties.4.5 Powder-free gloves shall be tested for glove powderresidue per 5.4 and comply with 21 CFR Parts 170199 (as
16、applicable).4.6 Powdered gloves shall be tested for glove powderamounts per 5.4 and comply with 21 CFR Parts 170199 (asapplicable).4.7 Protein:4.7.1 Gloves made from natural rubber shall be tested forcompliance to the recommended aqueous soluble proteincontent limit as described in 5.6,or4.7.2 Teste
17、d for compliance to the recommended antigenicprotein content limit as described in 5.7.5. Referee Test Methods5.1 HolesGloves shall be tested in accordance with TestMethod D 5151 to an AQL of 2.5 as specified in Table 1 or asrequired by each existing material specific ASTM glovestandard.5.1.1 Polyet
18、hylene gloves shall be tested using Test MethodD 7246 to an AQL of 2.5 as specified in Table 1.5.1.2 If food service gloves are made of a material type notdescribed or specified in an existing ASTM glove standard andthe material is a non-elastomer, then Test Method D 7246 shallbe used for the detect
19、ion of holes to an AQL of 2.5 as specifiedin Table 1.5.2 DimensionsGloves shall be tested for dimensions andtolerances in accordance with their individual standards orPractice D 3767 to an AQL of 4.0 per Table 1 and as specifiedin Table 2a through Table 2f. Measurement locations arespecified in Fig.
20、 1.5.2.1 Dimensions shall be expressed in millimetres (mm).5.2.2 Values shall meet the requirements established inTable 3.5.2.3 When the customer specifies thickness, it shall bemeasured using an appropriate instrument to measure thicknessin accordance with Test Methods D 412 and Practice D 3767 int
21、he location specified in Fig. 1.5.3 Physical PropertiesGloves shall be tested for physicalproperties as described Test Methods D 412 and to an AQL 4.0per Table 1 and as specified in Table 3a through Table 3h.Accelerated aging shall be conducted in accordance with TestMethod D 573. Accelerated aging
22、shall be conducted at70 6 2C for a period of 168 6 2 h on gloves that are no morethan 12 months old from the date of manufacture.5.3.1 Polyethylene gloves shall be tested for “MaximumForce at Yield” per Test Method D 882 using die type “D”.5.4 Powder (Powder-free Gloves)Gloves shall be testedfor res
23、idual powders in accordance with Test Method D 6124.Food Service gloves labeled as “Powder-free” shall adhere tothe powder residue limit established in Specification D 3578.All glove powders shall comply with 21 CFR Parts 170199,as applicable. A powder, release agent, or lubricant not listedwithin 2
24、1 CFR Parts 170199 shall not be used for glovesdesigned to contact food products.5.5 Powder (Powdered Gloves)Gloves shall be tested formaximum powder limit using Test Method D 6124. PowderedFood Service gloves shall adhere to the maximum powder limitestablished in Specification D 3578. All glove pow
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD73292007752STANDARDSPECIFICATIONFORFOODPREPARATIONANDFOODHANDLINGFOODSERVICEGLOVES 食品 制备 加工 服务 手套

链接地址:http://www.mydoc123.com/p-525183.html