《ASTM D7327-2017 red 7992 Standard Specification for HFC Blend B (CH2FCF3 CHF2CF3 and CO2)《HCFC混合物B(CH2FCF3 CHF2CF3 以及CO2)的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7327-2017 red 7992 Standard Specification for HFC Blend B (CH2FCF3 CHF2CF3 and CO2)《HCFC混合物B(CH2FCF3 CHF2CF3 以及CO2)的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7327 12D7327 17Standard Specification forHFC Blend B (CH2FCF3, CHF2CF3, and CO2)1This standard is issued under the fixed designation D7327; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers requirements for HFC Blend B as a fire-fighting medium.1.2 This specification does not address the fire-fight
3、ing equipment or hardware that employs HFC Blend B or the conditions ofemploying such equipment (for example, handhelds, fixed installations, etc.).1.3 This specification does not address the storage or transportation of HFC Blend B. Storage, handling, and transportationissues are addressed in Pract
4、ice D7326.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard1.5 This standard does not purport to address all of the safety concerns,
5、if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. Specific cautionary statements are given in Section 4.2. Referenced Documents2.1 ASTM Stan
6、dards:2D7326 Practice for Handling, Transportation, and Storage of HFC Blend B (CH2FCF3, CHF2 CF3, and CO2)D6806 Practice for Analysis of Halogenated Organic Solvents and Their Admixtures by Gas Chromatography2.2 ISO Standards:Standard:3ISO 3427 Gaseous Halogenated Hydrocarbons (Liquefied Gases)Taki
7、ng of a Sample2.3 ASHRAE Standard:4ASHRAE 34 Designation and Safety Classification of Refrigerants2.4 U.S. Government Standards:5CFR Title 49, Part 172, Subpart D, U.S. Department of Transportation (DOT), Marking Requirements of Packaging forTransportationCFR Title 49, Part 172.101 Tables of Hazardo
8、us Materials and Special Provisions2.5 AHRI Standards:Standard:62008 Appendix C for Analytical Procedures for AHRI Standard 700-2006700-20143. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 HFChydrofluorocarbon; a chemical compound in which the compound molecule is comprised exc
9、lusively of hydrogen,chlorine, fluorine and carbon atoms.1 This specification is under the jurisdiction of ASTM Committee D26 on Halogenated Organic Solvents and Fire Extinguishing Agents and is the direct responsibilityof Subcommittee D26.09 on Fire Extinguishing Agents.Current edition approved Sep
10、t. 1, 2012Feb. 1, 2017. Published October 2012February 2017. Originally approved in 2007. Last previous edition approved in 20072012as D7327- 07. -12. DOI: 10.1520/D7327-12.10.1520/D7327-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at servic
11、eastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standardsstandards Document Summary page on the ASTM website.3 Available fromAmerican National Standards Institute, 11 W. 42nd St., 13thInstitute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.10036, http:/www.ansi.o
12、rg.4 Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA 30329. 30329,http:/www.ashrae.org.5 Available from Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20036.U.S. Government Pub
13、lishing Office (GPO), 732 N. CapitolStreet, NW, Washington, DC 20401-0001, http:/www.gpo.gov.6 Available from Air-Conditioning, Heating, and Refrigeration Institute, Institute (AHRI), 2111 Wilson Blvd., Suite 500, Arlington, VA 22201.22201, http:/www.ahrinet.org.This document is not an ASTM standard
14、 and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases on
15、ly the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.2 HFC Blend Btertiary blend comprised of HFC-134a (1,1,1,2-tetrafluoroethane), HF
16、C-125 (pentafluoroethane), andcarbon dioxide (CO2); a compound used to inert, extinguish, or suppress a fire or explosion hazard.3.1.2.1 DiscussionThe terminology system for fluorine-containing compounds (described in detail in ASHRAE Standard 34) provides a convenientmeans to reference the structur
17、e of individual compounds. By definition, the first digit of the numbering system represents one lessthan the number of carbon atoms in the compound molecule; the second digit, one more than the number of hydrogen atoms inthe compound molecule; and the third digit, the number of fluorine atoms in th
18、e compound molecule. Unaccounted for valencerequirements are assumed to be chlorine atoms. For example, the designation HFC-123 indicates two carbon atoms (1 + 1), twohydrogen atoms (3-1), and four fluorine atoms (4). The “a” designation at the end of the naming convention relates to the symmetryof
19、the molecule.Example: CH2FCF3 = HFC-134a4. Material Requirements4.1 Type I Mixtures of HFC Blend B and Nitrogen:4.1.1 The nitrogen (N2) partial pressure shall be such that the safe working pressure of the receiving vessel is not exceeded. Toprevent excessive pressure, the fill density of HFC Blend B
20、 within a container should not exceed that needed to achieve completefilling of the container at the maximum envisaged storage temperature. For example, for the U.S. DOT 4BA500 cylinder, thenitrogen partial pressure shall not exceed 316 psig at 70F70 F (21.8 bar at 21C)21 C) for a 58 lb/ft3 (930 kg/
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD73272017RED7992STANDARDSPECIFICATIONFORHFCBLENDBCH2FCF3CHF2CF3ANDCO2HCFC 混合物 BCH2FCF3CHF2CF3 以及

链接地址:http://www.mydoc123.com/p-525177.html