ASTM D7296-2012 0625 Standard Practice for Collection of Settled Dust Samples Using Dry Wipe Sampling Methods for Subsequent Determination of Beryllium and Compounds《利用干扫取样法收集固定尘灰后.pdf
《ASTM D7296-2012 0625 Standard Practice for Collection of Settled Dust Samples Using Dry Wipe Sampling Methods for Subsequent Determination of Beryllium and Compounds《利用干扫取样法收集固定尘灰后.pdf》由会员分享,可在线阅读,更多相关《ASTM D7296-2012 0625 Standard Practice for Collection of Settled Dust Samples Using Dry Wipe Sampling Methods for Subsequent Determination of Beryllium and Compounds《利用干扫取样法收集固定尘灰后.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7296 12Standard Practice forCollection of Settled Dust Samples Using Dry WipeSampling Methods for Subsequent Determination ofBeryllium and Compounds1This standard is issued under the fixed designation D7296; the number immediately following the designation indicates the year oforiginal
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the collection of settled dust con-taining ber
3、yllium and/or beryllium compounds on surfacesusing the dry wipe sampling method. These samples arecollected in a manner that will permit subsequent extractionand determination of beryllium and compounds in the wipesusing laboratory analysis techniques such as atomic spectrom-etry or fluorescence det
4、ection.1.2 This practice is limited in its scope to applications wherewetted wipe sampling (using Practice D6966) or vacuumsampling (using Practice D7144) is not physically feasible (forexample, if the surface to be wiped would be compromised byuse of wetted wipes).1.3 This practice does not address
5、 the sampling designcriteria (that is, sampling plan which includes the number andlocation of samples) that are used for clearance, hazardevaluation, risk assessment, and other purposes. To provide forvalid conclusions, sufficient numbers of samples should beobtained as directed by a sampling plan.A
6、dditional guidance isprovided in Guide D7659.1.4 This practice contains notes that are explanatory and arenot part of the mandatory requirements of this practice.1.5 The values stated in SI units are to be regarded asstandard.1.6 This standard does not purport to address all of thesafety concerns, i
7、f any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1356 Terminology Relating to Sampling and Ana
8、lysis ofAtmospheresD4840 Guide for Sample Chain-of-Custody ProceduresD6966 Practice for Collection of Settled Dust SamplesUsing Wipe Sampling Methods for Subsequent Determi-nation of MetalsD7144 Practice for Collection of Surface Dust by Micro-vacuum Sampling for Subsequent Metals DeterminationD7659
9、 Guide for Strategies for Surface Sampling of Metalsand Metalloids for Worker ProtectionD7707 Specification for Wipe Sampling Materials for Be-ryllium in Surface Dust3. Terminology3.1 For definitions of terms not listed here, see TerminologyD1356.3.2 Definitions:3.2.1 batch, na group of field or qua
10、lity control (QC)samples that are collected or processed together at the sametime using the same reagents and equipment.3.2.2 sampling location, na specific area within a sam-pling site that is subjected to sample collection. D69663.2.2.1 DiscussionMultiple sampling locations are com-monly designate
11、d for a single sampling site (see 3.2.3).3.2.3 sampling site, na local geographic area that containsthe sampling locations (see 3.2.2). D69663.2.3.1 DiscussionA sampling site is generally limited toan area that is easily covered by walking.3.2.4 dry wipe, na suitable non-wetted wiping medium.3.2.4.1
12、 DiscussionThese are to be distinguished fromwipes as defined in Practice D6966 and Specification D7707,which are wet wipes.3.3 Definitions of Terms Specific to This Standard:3.3.1 field blank, na dry wipe (see 3.2.4) that is exposedto the same handling as field samples except that no sample iscolle
13、cted (no surface is actually wiped).3.3.1.1 DiscussionAnalysis results from field blanks pro-vide information on the analyte background level in the drywipe, combined with the potential contamination experiencedby samples collected within the batch (see 3.2.1) resulting fromhandling.1This practice i
14、s under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.04 on Workplace Air Quality.Current edition approved . Published May 2012. Originally approved in 2006.Last previous edition approved in 2006 as D7296 - 06. DOI:10.1520/D7296-12.2For ref
15、erenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, We
16、st Conshohocken, PA 19428-2959, United States.4. Summary of Practice4.1 Wipe samples of settled dust are collected on surfacesfrom areas of known dimensions with dry wipes satisfyingcertain requirements, using a specified pattern of wiping.4.2 The collected dry wipes are then ready for subsequentsam
17、ple preparation and analysis for the measurement ofberyllium and compounds.5. Significance and Use5.1 This practice is intended for the collection of settled dustsamples for the subsequent measurement of beryllium andcompounds. The practice is meant for use in the collection ofsettled dust samples t
18、hat are of interest in clearance, hazardevaluation, risk assessment, and other purposes.5.2 This practice is intended solely for the collection ofsettled dust samples from hard, relatively smooth nonporoussurfaces that may be compromised by water or other wettingagents and that are therefore not sui
19、table for wet wipe samplingusing Practice D6966 or micro-vacuum sampling using Prac-tice D7144. Use of this practice for any purpose other than theintended purpose is discouraged due to the limited collectionefficiency and high variability of dry wipe sampling as com-pared to wetted wipe or micro-va
20、cuum sampling3.5.3 This practice is less effective for collecting settled dustsamples from surfaces with substantial texture such as roughconcrete, brickwork, textured ceilings, and soft fibrous surfacessuch as upholstery and carpeting. Micro-vacuum samplingusing Practice D7144 may be more suitable
21、for these surfaces.6. Apparatus6.1 Sampling TemplatesOne or more of the following: 10cm by 10 cm (minimum dimensions) reusable or disposablealuminum or plastic template(s), or disposable cardboardtemplates, (full-square, rectangular, square “U-shaped,” rect-angular “U-shaped,” or “L-shaped,” or both
22、); or templates ofalternative areas having accurately known dimensions (seeNote 1). Templates shall be capable of lying flat on a surface.NOTE 1For most surfaces, it is recommended to collect settled dustfrom a minimum surface area of 100 cm2to provide sufficient material forsubsequent laboratory an
23、alysis. However, larger areas (for example, 30 cmby 30 cm) may be appropriate for surfaces having little or no visiblesettled dust, while a smaller sampling area (for example, 10 cm by 10 cm)may be appropriate for surfaces with high levels of visible settled dust. Itis recommended to have a suite of
24、 templates with various samplingdimensions.6.2 Dry Wipes, for collection of settled dust samples fromsurfaces. The background metal(s) content of the dry wipesshould be as low as possible. At a maximum, the backgroundlevel of beryllium shall be no more than one-tenth the targetconcentration to be me
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD729620120625STANDARDPRACTICEFORCOLLECTIONOFSETTLEDDUSTSAMPLESUSINGDRYWIPESAMPLINGMETHODSFORSUBSEQUENTDETERMINATIONOFBERYLLIUMANDCOMPOUNDS

链接地址:http://www.mydoc123.com/p-525069.html