ASTM D7281-2007(2013) 9375 Standard Test Method for Determining Water Migration Resistance Through Roof Membranes《通过房顶隔膜测定水分迁移阻力的标准试验方法》.pdf
《ASTM D7281-2007(2013) 9375 Standard Test Method for Determining Water Migration Resistance Through Roof Membranes《通过房顶隔膜测定水分迁移阻力的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7281-2007(2013) 9375 Standard Test Method for Determining Water Migration Resistance Through Roof Membranes《通过房顶隔膜测定水分迁移阻力的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7281 07 (Reapproved 2013)Standard Test Method forDetermining Water Migration Resistance Through RoofMembranes1This standard is issued under the fixed designation D7281; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of watermigration resistance of roof membranes including built-u
3、p roofmembranes, modified bitumen, and single ply roof membranes.The procedures were developed to determine the potential forleakage of water through the roof membranes resulting from astanding head of water and when pressurized with air from theunderside.1.2 The values stated in SI units are to be
4、regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and de
5、termine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2G154 Practice for Operating Fluorescent Ultraviolet (UV)Lamp Apparatus for Exposure of Nonmetallic Materials3. Terminology3.1 Definitions:3.1.1 adhereto cause two surfaces to be held together
6、 byadhesion. Roof membranes are often “partially-” or “totally-adhered” to a substrate.3.1.2 battena narrow band or plate that is used to fasten orprevent the displacement of a single ply membrane.3.1.3 delaminationseparation between lamination orbonded material or component; for example, laminated
7、layersof rigid insulation or the felt plies in a built-up roof.3.1.4 field seama splice made in the field of a single plymembrane that joins two sheets together using an adhesive,splicing tape, heat, or solvent-welding.3.1.5 mechanically fastened membranesa single ply orbase ply (part of a multi-lay
8、er system) membrane that has beenpositively attached at intervals to the substrate, usually withfasteners and/or other mechanical devices, such as battens.3.1.6 NPTNational Pipe Thread.4. Summary of Test Method4.1 Roofing membranes are conditioned and installed in theleakage test apparatus (Fig. 1).
9、A152-mm (6-in.) head of wateris maintained over the sample for 7 days at ambient conditions,21C (70F). At the end of the 7 day period, air shall beintroduced into the bottom section of the apparatus, increasingthe pressure to 6.9 kPa (1 psig) and immediately released toambient conditions. This cycle
10、 is repeated 25 times.5. Significance and Use5.1 This test method provides a means of evaluating roofmembranes, seams, and laps for resistance to water migrationfrom standing water on the roof. This test method evaluatesroof membranes when first applied and also after simulateddeterioration caused b
11、y the ultraviolet energy of the sun.6. Apparatus6.1 The test apparatus consists of top section, a supportplate, and a bottom section, which are clamped together withthe sample being evaluated placed as a diaphragm between thetop sections and the support plate.6.1.1 The top section consists of a 203-
12、mm (8-in.) diameter,6-mm (14-in.) wall thickness 203-mm (8-in.) length of clearacrylic pipe, which is cemented to a 305-mm (12-in.) diameterflange.6.1.2 The support plate is a round poly(vinyl chloride) plate,6-mm (14-in.) thick and a 241-mm (912-in.) diameter with6-mm (14-in.) diameter holes spaced
13、 25 mm (1 in.) on center.6.1.3 The bottom section consists of a 305-mm (12-in.)diameter flange attached to a 203-mm (8-in.) diameter, 6-mm(14-in.) wall thickness 152-mm (6-in.) length of clear acrylicpipe, which is fabricated with two threaded holes 6 mm (14 in.)NPT. These holes are used after the t
14、est apparatus sections are1This test method is under the jurisdiction ofASTM Committee D08 on Roofingand Waterproofing and is the direct responsibility of Subcommittee D08.20 onRoofing Membrane Systems.Current edition approved May 1, 2013. Published May 2013. Originallyapproved in 2007. Last previou
15、s edition approved in 2007 as D7281 07. DOI:10.1520/D7281-07R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM websi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7281200720139375STANDARDTESTMETHODFORDETERMININGWATERMIGRATIONRESISTANCETHROUGHROOFMEMBRANES 通过

链接地址:http://www.mydoc123.com/p-525040.html