ASTM D7236-2007 459 Standard Test Method for Flash Point by Small Scale Closed Cup Tester (Ramp Method)《小型闭杯试验器对闪点的测定用标准试验方法(斜坡法)》.pdf
《ASTM D7236-2007 459 Standard Test Method for Flash Point by Small Scale Closed Cup Tester (Ramp Method)《小型闭杯试验器对闪点的测定用标准试验方法(斜坡法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7236-2007 459 Standard Test Method for Flash Point by Small Scale Closed Cup Tester (Ramp Method)《小型闭杯试验器对闪点的测定用标准试验方法(斜坡法)》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7236 07An American National StandardStandard Test Method forFlash Point by Small Scale Closed Cup Tester (RampMethod)1, 2This standard is issued under the fixed designation D 7236; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis flash point test method is a dynamic test method and depends on a definite rate of temp
3、eratureincrease to control the precision of the test method. The rate of heating may not in all cases give theprecision quoted in the test method because of the low thermal conductivity of certain materials. Theuse of an equilibrium method such as Test Methods D 3828, Method B improves the predictio
4、n offlammability for such materials, as the vapors above the test specimen and the test specimen are closerto thermal equilibrium.Flash point values are a function of the apparatus design, the condition of the apparatus used, andthe operational procedure carried out. Flash point can therefore only b
5、e defined in terms of a standardtest method, and no general valid correlation can be guaranteed between results obtained by differenttest methods or with test apparatus different than that specified.1. Scope*1.1 This test method covers the determination of the flashpoint of aviation turbine fuel, di
6、esel fuel, kerosine and relatedproducts in the temperature range of 40 to 135C by a smallscale closed cup apparatus.1.2 This test method is only applicable to homogeneousmaterials that are liquid at or near ambient temperature and attemperatures required to perform the test.1.3 This test method is n
7、ot applicable to liquids contami-nated by traces of highly volatile materials.1.4 This test method is a dynamic method and depends on adefinite rate of temperature increase. It is one of many flashpoint methods available, and every flash point test method,including this one, is an empirical one.1.5
8、If the users specification requires a defined flash pointmethod, neither this test nor any other method should besubstituted for the prescribed method without obtaining com-parative data and an agreement from the specifier.1.6 The values stated in SI units are to be regarded asstandard. No other uni
9、ts of measurement are included in thisstandard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regu
10、latory limitations prior to use. For specific hazardstatements, see Section 7 and the Material Safety Data Sheetfor the product being tested.2. Referenced Documents2.1 ASTM Standards:3D 3828 Test Methods for Flash Point by Small Scale ClosedCup TesterD 4057 Practice for Manual Sampling of Petroleum
11、andPetroleum ProductsD 4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD 6299 Practice for Applying Statistical Quality AssuranceTechniques to Evaluate Analytical Measurement SystemPerformanceD 6300 Practice for Determination of Precision and BiasData for Use in Test Methods f
12、or Petroleum Products andLubricantsE 300 Practice for Sampling Industrial Chemicals2.2 ISO Standards:4ISO Guide 34 Quality Systems Guidelines for the Produc-tion of Reference Materials1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the dir
13、ect responsibility of SubcommitteeD02.08 on Volatility.Current edition approved Nov. 1, 2007. Published January 2008. Originallyapproved in 2006. Last previous edition approved in 2006 as D 723606.2This test method is being jointly developed and harmonized with the EnergyInstitute.3For referenced AS
14、TM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4t
15、h Floor, New York, NY 10036.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.ISO Guide 35 Certification of Reference MaterialGeneraland Statistical Principles3. Termino
16、logy3.1 Definitions:3.1.1 flash point, nlowest temperature corrected to apressure of 101.3 kPa, at which application of a test flamecauses the vapors of a test specimen of the sample to ignitemomentarily under the specified conditions of the test.3.2 Definitions of Terms Specific to This Standard:3.
17、2.1 dynamic, adjthe condition where the vapor abovethe test specimen, and the test cup, are not in temperatureequilibrium at the time the test flame is applied.3.2.2 ramp method, nin flash point methods, method thathas a test temperature increase at a set rate.4. Summary of Test Method4.1 A 2 6 0.1
18、mL test specimen is introduced into the testcup that is then heated automatically at a constant rate of 2 60.5C/min. A gas test flame is directed through an openingshutter, in the test cup lid, at specified temperature intervalsuntil a flash is detected by the automatic flash detector. Theflash is r
19、eported as defined in 3.1.1.5. Significance and Use5.1 The flash point temperature is one measure of thetendency of the test specimen to form a flammable mixturewith air under controlled laboratory conditions. It is only oneof a number of properties that must be considered in assessingthe overall fl
20、ammability hazard of a material.5.2 Flash point is used in shipping and safety regulations todefine flammable and combustible materials and classify them.Consult the particular regulation involved for precise defini-tions of these classifications.5.3 This test method can be used to measure and descr
21、ibethe properties of materials in response to heat and a test flameunder controlled laboratory conditions and shall not be used todescribe or appraise the fire hazard or fire risk of materialsunder actual fire conditions. However, results of this testmethod may be used as elements of a fire risk ass
22、essment, thattakes into account all of the factors that are pertinent to anassessment of the fire hazard of a particular end use.6. Apparatus6.1 Flash Point ApparatusThe apparatus consists of anelectrically heated test cup that is controlled automatically togive a temperature increase of 2.0 6 0.5C/
23、min, a lid andshutter assembly, a pilot and test flame, an automatic flashdetector and a temperature display that displays and holds thetest temperature when a flash is detected. The key parts anddimensions are described in Annex A1 and illustrated in Fig.A1.1.6.2 Syringe, 2 mL, adjusted to deliver
24、2.00 6 0.1 mL.6.3 Barometer, accurate to 0.5 kPa. Barometers pre-corrected to give sea level readings, such as those used atweather stations and airports, shall not be used.NOTE 1Automatic barometric correction in accordance with 12.2 maybe installed in the apparatus.6.4 Cooling Bath or Freezer, for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD72362007459STANDARDTESTMETHODFORFLASHPOINTBYSMALLSCALECLOSEDCUPTESTERRAMPMETHOD 小型 试验 闪点 测定 标准 方法

链接地址:http://www.mydoc123.com/p-524901.html