《ASTM D7082-2015 red 1636 Standard Specification for Polyethylene Stay In Place Form System for End Walls for Drainage Pipe《排水管端壁聚乙烯结构模板系统的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7082-2015 red 1636 Standard Specification for Polyethylene Stay In Place Form System for End Walls for Drainage Pipe《排水管端壁聚乙烯结构模板系统的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7082 04 (Reapproved 2010)D7082 15 An American National StandardStandard Specification forPolyethylene Stay In Place Form System for End Walls forDrainage Pipe1This standard is issued under the fixed designation D7082; the number immediately following the designation indicates the year
2、oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This specification addresses the requirements for
3、polyethylene stay in place forms for end walls or head walls for use withstandard storm drainage systems.1.2 The wall form system consists of a base wall form, a cap, an optional riser to adjust the height of the wall above the pipe,and an optional adaptor to adjust the pipe opening to accommodate s
4、maller pipe sizes.1.3 The form system is manufactured using the rotational molding process and is available in different colors.1.4 The values stated in SI units are to be regarded as the standard, the inch-pounds in bracketsparentheses are given forinformation only.1.5 This standard does not purpor
5、t to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatoryrequirements prior to use.NOTE 1There is no known ISO equivalent to this st
6、andard.2. Referenced Documents2.1 ASTM Standards:2D638 Test Method for Tensile Properties of PlasticsD648 Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise PositionD790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical In
7、sulating MaterialsD883 Terminology Relating to PlasticsD1238 Test Method for Melt Flow Rates of Thermoplastics by Extrusion PlastometerD1505 Test Method for Density of Plastics by the Density-Gradient TechniqueD1600 Terminology for Abbreviated Terms Relating to PlasticsD1693 Test Method for Environm
8、ental Stress-Cracking of Ethylene PlasticsD4883 Test Method for Density of Polyethylene by the Ultrasound TechniqueD7209 Guide for Waste Reduction, Resource Recovery, and Use of Recycled Polymeric Materials and Products (Withdrawn2015)33. Terminology3.1 Definitions:3.1.1 Definitions used in this spe
9、cification are in accordance with definitions in Terminology D883 and abbreviations inaccordance with Terminology D1600 unless otherwise indicated.3.1.2 end walla wall installed at the outlet of a storm drainage pipe.3.1.3 head walla wall installed at the inlet of a storm drainage pipe.4. Ordering I
10、nformation4.1 Number and color of base wall forms,4.2 Number and color of riser forms,1 This specification is under the jurisdiction of ASTM Committee D20 on Plastics and is the direct responsibility of Subcommittee D20.24 on Plastic Building Products.Current edition approved April 1, 2010Oct. 1, 20
11、15. Published June 2010October 2015. Originally approved in 2004. Last previous edition approved in 20042010 as D7082- 04.04(2010). DOI: 10.1520/D7082-04R10. 10.1520/D7082-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For
12、Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not
13、 be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end
14、 of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.3 Number and color of caps, and4.4 Number, color and size of adaptors.5. Materials and Manufacture5.1 The material used shall be a polyethylene meeting the criteria in
15、 Table 1.5.2 Only virgin materials (Guide D7209) shall be used.5.3 This product shall be manufactured using a rotational molding process.6. Requirements6.1 Wall System Description:6.1.1 Base wall form is hollow with opening at the top to accept fill material and designed to accept either cap or rise
16、r section.Base wall has opening in the center for pipe and adaptors as needed. Pipe is secured to base wall form with galvanized screws.(See Fig. 1.)6.1.2 Riser form is hollow with opening at top to accept fill material and cap section. Multiple risers can be installed on basewall. (See Fig. 2.)6.1.
17、3 Cap fits on top of base wall or riser and is secured with galvanized screws. (See Fig. 1.)6.1.4 Adaptor section is used to adjust the size of the pipe opening as needed. Adaptor is secured to base wall form withgalvanized screws and pipe is secured to adaptor with galvanized screws. (See Fig. 2.)6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD70822015RED1636STANDARDSPECIFICATIONFORPOLYETHYLENESTAYINPLACEFORMSYSTEMFORENDWALLSFORDRAINAGEPIPE

链接地址:http://www.mydoc123.com/p-524448.html