ASTM D7065-2006 Standard Test Method for Determination of Nonylphenol Bisphenol A p-tert-Octylphenol Nonylphenol Monoethoxylate and Nonylphenol Diethoxylate in Environmental Waters.pdf
《ASTM D7065-2006 Standard Test Method for Determination of Nonylphenol Bisphenol A p-tert-Octylphenol Nonylphenol Monoethoxylate and Nonylphenol Diethoxylate in Environmental Waters.pdf》由会员分享,可在线阅读,更多相关《ASTM D7065-2006 Standard Test Method for Determination of Nonylphenol Bisphenol A p-tert-Octylphenol Nonylphenol Monoethoxylate and Nonylphenol Diethoxylate in Environmental Waters.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7065 06Standard Test Method forDetermination of Nonylphenol, Bisphenol A, p-tert-Octylphenol, Nonylphenol Monoethoxylate and NonylphenolDiethoxylate in Environmental Waters by GasChromatography Mass Spectrometry1This standard is issued under the fixed designation D 7065; the number im
2、mediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 T
3、his test method covers determination of nonylphenol(NP), nonylphenol ethoxylate (NP1EO), nonylphenol di-ethoxylate (NP2EO), octylphenol (OP), and bisphenolA(BPA)that are partitioned into organic solvent, separated using gaschromatography and detected with mass selective detection.These compounds or
4、isomer mixtures are qualitatively andquantitatively determined by this method. This method adheresto selected ion monitoring mass spectrometry but full scanmass spectrometry has also been shown to work well underthese conditions. Either analysis may be used.1.2 The method detection limit (MDL) repor
5、ting limit (RL)for NP, NP1EO, NP2EO, OP, and BPA are listed in Table 1.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use.
6、 It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterD 3694 Practices for Preparation of Sa
7、mple Containers andfor Preservation of Organic ConstituentsD 3856 Guide for Good Laboratory Practices in Laborato-ries Engaged in Sampling and Analysis of WaterD 5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisD 5905 Practice for the Preparation of
8、 Substitute Wastewa-terE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 NP represents nonylphenol which is mixed isomers ofbranched p-nonylphenol. Commercial nonylphenol (NP) isproduced by the reaction of phenol with commercial nonene
9、.Commercial nonene is not simply a linear C9H18alpha olefin;it is a complex mixture of predominantly nine-carbon olefins,called propylene trimer, containing no linear isomers. Thissynthesis results in a mixture of various branched nonylphenolisomers rather than a discrete chemical structure. The bra
10、nchednonyl group is positioned predominantly in the para positionon the phenol ring.3.2 OP represents octylphenol. Commercial octylphenol isproduced by the reaction of phenol and diisobutylene toproduce predominantly the 4-(1,1,3,3-tetramethylbutyl)phenolisomer.3.3 BPArepresents bisphenolA. Commerci
11、al bisphenolAisproduced by the condensation reaction of phenol and acetoneto produce predominantly the 4,48-isopropylidenediphenol iso-mer.3.4 NP1EO represents branched nonylphenol monoethoxy-late.3.5 NP2EO represents branched nonylphenol diethoxylate.3.6 n-NP and n-NP1EO represent normal straight c
12、hainnonylphenol and nonylphenol ethoxylate. n-NP and n-NP1EOare used in this method as surrogates. They are not producedcommercially and are not expected to be found in environmen-tal waters.1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of
13、 Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved Dec. 15, 2006. Published January 2007.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
14、information, refer to the standards Document Summary page onthe ASTM website.TABLE 1 MDL and Reporting LimitsAnalyte MDL, (g/L) Reporting Range (g/L)NP 0.9 5.0-80.0NP1EO 1.2 10.0-160.0NP2EO 1.8 20.0-320.0OP 0.2 1.0-16.0BPA 0.3 1.0-16.01Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700
15、, West Conshohocken, PA 19428-2959, United States.3.7 Environmental water shall refer to water tested usingthis method. See Section 5.4. Summary of Test Method4.1 For NP, NP1EO, NP2EO, BPA, and OP analysis, con-tinuous liquid-liquid extraction technique is used for watersamples.4.2 Continuous Liquid
16、-Liquid Extraction TechniqueA1-Lvolume of sample adjusted to pH 2 is extracted with methylenechloride. The methylene chloride extract is dried using sodiumsulfate if needed, concentrated to a volume of 0.5 mL, and thenanalyzed by GC/MS operated in the selected ion monitoring(SIM) or full scan mode.4
17、.3 The target compounds are identified by retention timeand confirmed by comparing the sample mass spectrum to thatof a known standard. The target compounds are quantitatedusing the quantitation ions of the target compounds utilizingthe internal standards acenaphthene-d10, and phenanthrene-d10.The f
18、inal report issued for each sample lists total concentrationof NP, NP1EO, NP2EO, BPA, and OP, if detected, or MDLs, ifnot detected, in g/L for water samples.5. Significance and Use5.1 Nonylphenol, octylphenol, and bisphenol A have beenshown to have toxic effects in aquatic organisms. The source ofno
19、nylphenol and octylphenol is prominently from the use ofcommon commercial surfactants. The most widely used sur-factant is NPEO which has an average ethoxylate chain of 9mol of ethoxylate. The ethoxylate chain is readily biodegradedto form NP1EO and NP2EO, nonylphenol carboxylate (NPEC)and, under an
20、aerobic conditions, nonylphenol. Nonylphenolwill also biodegrade, but may be released into environmentalwaters directly at trace levels. This method has been investi-gated for use with surface water and waste treatment effluentsamples and is applicable to these matrices. It has not beeninvestigated
21、for use with salt water or solid sample matrices.6. Interferences6.1 Method interferences may be caused by contaminants insolvents, reagents, glassware and other apparatus that lead todiscrete artifacts or elevated baseline in the selected ion currentprofiles.All of these materials are routinely dem
22、onstrated to befree from interferences by analyzing laboratory reagent blanksunder the same conditions as the samples.6.2 All glassware is scrupulously cleaned. All glassware iswashed in hot water with detergent such as powderedAlconox,Deto-Jet, Luminox, or Citrojet, rinsed in hot water and rinsedwi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD70652006STANDARDTESTMETHODFORDETERMINATIONOFNONYLPHENOLBISPHENOLAPTERTOCTYLPHENOLNONYLPHENOLMONOETHOXYLATEANDNONYLPHENOLDIETHOXYLATEINENVIRONMENTALWATERSPDF

链接地址:http://www.mydoc123.com/p-524421.html