ASTM D7030-2004(2017) 8750 Standard Test Method for Short Term Creep Performance of Corrugated Fiberboard Containers Under Constant Load Using a Compression Test Machine《用压缩试验器测定恒定.pdf
《ASTM D7030-2004(2017) 8750 Standard Test Method for Short Term Creep Performance of Corrugated Fiberboard Containers Under Constant Load Using a Compression Test Machine《用压缩试验器测定恒定.pdf》由会员分享,可在线阅读,更多相关《ASTM D7030-2004(2017) 8750 Standard Test Method for Short Term Creep Performance of Corrugated Fiberboard Containers Under Constant Load Using a Compression Test Machine《用压缩试验器测定恒定.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7030 04 (Reapproved 2017)Standard Test Method forShort Term Creep Performance of Corrugated FiberboardContainers Under Constant Load Using a Compression TestMachine1This standard is issued under the fixed designation D7030; the number immediately following the designation indicates the
2、 year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers determining the resistance
3、of anempty paper corrugated shipping container to a verticallyapplied constant compression load for a specified time. The testmethod may also include palletized or unitized loads made ofsuch containers. The boxes are tested in the orientation thatthey are most likely to be stacked in a unitized or p
4、alletizedload.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns
5、, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally reco
6、gnized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D642 Test Method for
7、 Determining Compressive Resistanceof Shipping Containers, Components, and Unit LoadsD644 Test Method for Moisture Content of Paper andPaperboard by Oven Drying (Withdrawn 2010)3D685 Practice for Conditioning Paper and Paper Productsfor TestingD996 Terminology of Packaging and Distribution Environ-m
8、entsD4332 Practice for Conditioning Containers, Packages, orPackaging Components for TestingD4577 Test Method for Compression Resistance of a Con-tainer Under Constant LoadE4 Practices for Force Verification of Testing MachinesE122 Practice for Calculating Sample Size to Estimate, WithSpecified Prec
9、ision, the Average for a Characteristic of aLot or Process3. Terminology3.1 DefinitionsGeneral definitions for the packaging anddistribution environments are found in Terminology D996.3.2 Definitions of Terms Specific to This Standard:3.2.1 constant loada load that is invariable or unchanging.3.2.2
10、creepcontinued deformation over time while underconstant load.3.2.3 loadthe force applied to a body.3.2.4 static loadan imposed stationary force, constant inmagnitude and direction.4. Significance and Use4.1 In the distribution system, the packaged product may bestored for a period of time in a mann
11、er such that one or morecontainers are stacked on one another. The bottom package isthus continually subjected to a constant compression load.4.2 This test method subjects an empty container to apredetermined static load and to specified atmosphericconditions, if required, over a short period of tim
12、e using fixedplaten compression testing equipment. Deflection is measuredover time.1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.21 on ShippingContainers and Systems - Application of Performance Test Methods.Current
13、 edition approved May 1, 2017. Published July 2017. Originally approvedin 2004. Last previous edition approved in 2009 as D7030 04 (2009). DOI:10.1520/D7030-04R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book
14、 of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesT
15、his international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade
16、(TBT) Committee.14.3 Deflection versus time data can be used to predict timeto failure of corrugated shipping containers under constantload.5. Apparatus5.1 Fixed-Platen Testing MachineTwo platens, flat towithin 0.01 in. (0.25 mm) for each 12 in. (304.8 mm) in length,one of which is movable in the ve
17、rtical direction so as tocompress the container between the platens. One is the loadmeasuring platen, and both should be of sufficient size so thatthe test container does not extend beyond the edges of theplatens. Both platens are fixed in the horizontal directions sothat the lateral movement is not
18、 greater than 0.05 in. (1.3 mm),and are held parallel throughout the test to within 0.04 in. (1mm) for each 12 in. (304.8 mm) in the length and widthdimensions. See Fig. 1. The testing machine should be capableto maintain load within 1 % of the required level for theduration of the test.5.2 Closing
19、Equipment for Fiberboard BoxesSuitable ma-terials and application equipment for closing boxes should beused. If adhesives are used, sealing boards described in TestMethod D642 may be needed.5.3 Conditioning ApparatusAdequate facilities shall beprovided to maintain a conditioned atmosphere of tempera
20、tureand humidity as required for the purpose of the test.5.4 Miscellaneous EquipmentDrying oven, scales, knife,saws, and the like, for use in determination of the moisturecontent or for making other supplementary tests of the mate-rials from which the containers are made.6. Calibration6.1 The accura
21、cy of the test equipment must be verified toensure reliable test data.6.1.1 The overall system accuracy of the recorded or indi-cated applied load (force) shall be verified in accordance withPractice E4. The verified loading range shall be specified, anderrors within the loading range shall not exce
22、ed 61.0 % of thereading (as calculated in Practice E4). If testing below thePractice E4 verified loading range is desired, then the maxi-mum permissible error shall not exceed 60.2 % of the fullrange of the force sensor, calculated as follows:E 5 FS30.002FIG. 1 Corrugated Container Under Creep Test
23、in Compression Test MachineD7030 04 (2017)2where:E = maximum permissible error, lbf or N, andFS= force sensors full range, lbf or N.6.1.2 The accuracy of the recorded or indicated platendisplacement must be verified in accordance with the equip-ment manufacturers recommended procedures. The error,in
24、cluding the effects of any backlash in the loading system,shall not exceed 60.1 in. (62.5 mm).6.1.3 The accuracy of the platen travel rate at 0.5 in./min(12.7 mm/min) must be verified throughout each loading rangein accordance with the equipment manufacturers recom-mended procedures. The error, incl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7030200420178750STANDARDTESTMETHODFORSHORTTERMCREEPPERFORMANCEOFCORRUGATEDFIBERBOARDCONTAINERSUNDERCONSTANTLOADUSINGACOMPRESSIONTESTMACHINE

链接地址:http://www.mydoc123.com/p-524299.html