ASTM D6978-2005 Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chemotherapy Drugs《防化学理疗药物渗透的医用手套的评定的标准实施规程》.pdf
《ASTM D6978-2005 Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chemotherapy Drugs《防化学理疗药物渗透的医用手套的评定的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6978-2005 Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chemotherapy Drugs《防化学理疗药物渗透的医用手套的评定的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6978 05Standard Practice forAssessment of Resistance of Medical Gloves to Permeationby Chemotherapy Drugs1This standard is issued under the fixed designation D 6978; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a protocol for the assessment ofresistance of medical glove materials to permeation by
3、 poten-tially hazardous cancer chemotherapy drugs under conditionsof continuous contact. An assessment is made based on thepermeation (breakthrough) of nine chemotherapy drugsthrough the glove material over a certain period of time.1.2 It is emphasized that the conditions used in this assess-ment ar
4、e intended to approximate the worst-case condition forclinical uses. The data should be restricted to use on a relativebasis when comparing glove materials.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of
5、 this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 471 Test Method for Rubber PropertyEffect of LiquidsD 3577 Specification for Rubber Surgical GlovesD 3578 Specific
6、ation for Rubber Examination GlovesD 3767 Practice for RubberMeasurement of DimensionsD 5250 Specification for Poly(Vinyl Chloride) Gloves forMedical ApplicationD 6319 Specification for Nitrile Examination Gloves forMedical ApplicationD 6977 Specification for Polychloroprene ExaminationGloves for Me
7、dical ApplicationF 739 Test Method for Resistance of Protective ClothingMaterials to Permeation by Liquids or Gases Under Con-ditions of Continuous Contact3. Terminology3.1 DefinitionsSee Test Method F 739, Section 3 onTerminology for a full list of terms and definitions.3.1.1 breakthrough detection
8、 time, nthe time in minutesmeasured from the start of the test to the sampling time thatimmediately precedes the sampling time at which the perme-ation rate reaches 0.01 g/cm2/min. See Test Method F 739,section 12.4.2 for calculation of permeation rate with replen-ishment.3.1.2 validated statistical
9、 rationale, nrequires that anobjective cause or reason be stated as to why the initial test wasincorrect.4. Significance and Use4.1 The objective of this practice is to provide a uniformprocedure for assessing the resistance of medical glove mate-rials to permeation by chemotherapy drugs, and to est
10、ablish aconsistent reporting of the test data.5. Test Protocol5.1 Summary of Test Method:5.1.1 The gloves in question shall be tested in accordancewith the method set out in Test Method F 739, Procedure A.5.1.2 The resistance of a medical glove material to perme-ation by chemotherapy drugs shall be
11、determined by measuringthe breakthrough detection time of the drugs through the glovematerial. The test method involves using the test material serveas a membrane (partition) between the two halves of a test cell.One half of the cell shall contain the donor solution of the testdrug and the other hal
12、f shall contain the appropriate collectionmedium, that is, distilled water or other liquid, which does notinfluence the permeation of the drug being tested. A test drugpermeates through the sample material when the test drug isable to pass through the test material. As the test drugcontinuously pass
13、es through the sample material, its concen-tration increases over time. The collection medium shall besampled at recorded time intervals and analyzed quantitativelyto determine the concentration of the permeated drug. Theconcentration of the drug in the collection medium shall beused to calculate th
14、e breakthrough detection time and perme-ation rate (see 3.1.2), in accordance with Test Method F 739.5.2 Test Protocol:5.2.1 Test Material Selection:5.2.1.1 Three medical gloves that meet the appropriateASTM standards (Specifications D 3577, D 3578, D 5250,D 6319, and D 6977) shall be selected and u
15、sed to produce test1This practice is under the jurisdiction of ASTM Committee D11 on Rubber andis the direct responsibility of Subcommittee D11.40 on Consumer Rubber Products.Current edition approved April 1, 2005. Published April 2005.2For referenced ASTM standards, visit the ASTM website, www.astm
16、.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.samples. M
17、anually measure each glove thickness with athickness gage that has a presser foot pressure that meets therequirement of Practice D 3767, and graduations to 20 m. Foreach medical glove, record manual thickness measurementsfrom two distinct areas of the medical glove: palm and cuff.From these measurem
18、ents determine the thinner area of theglove between the palm and cuff. Obtain test samples from thethinner area of the glove.5.2.1.2 Cut one 5 by 5-cm piece of material from the palmor cuff of each test medical glove, whichever area measuredthinnest. Identify the outer side of the sample.5.2.1.3 One
19、 test sample shall be obtained from each of thethree test medical gloves. As a result, there will be a minimumof 27 test samples obtained when testing against the nine testdrugs. The number of test drugs, nine, is a minimum.5.2.2 Representative Drugs to be Tested:5.2.2.1 The chemotherapy drugs used
20、in testing shall incor-porate the different classes of clinical drugs. The number ofdrugs tested shall reflect a minimum of nine currently usedclinical drugs.5.2.2.2 The clinical drugs selected shall include at least thefollowing seven drugs: Carmustine, Cyclophosphamide, Doxo-rubicin, Etoposide, Fl
21、uorouracil, Paclitaxel, and Thiotepa. SeeTable 1.5.2.2.3 The testing shall be completed with an additionaltwo clinical drugs that can be selected by the user of thispractice. Table 2 is available as a guide for selecting additionalchemotherapy drugs.5.2.2.4 The clinical drugs called for in this prac
22、tice shall bepurchased from pharmaceutical drug manufacturers or autho-rized distributors of pharmaceuticals. Each test drug shall beprepared using the manufacturers recommended solvent. Thepreparation procedure shall be documented.5.2.2.5 The drug solution shall be prepared with the recom-mended so
23、lvent and at the highest concentration of the drug towhich a healthcare worker might be exposed during handlingas referenced in the most recent edition of Physicians DeskReference, or the package insert of the test drug (see Table 1).5.2.3 Test Conditions:5.2.3.1 The test shall be conducted at 35 6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD69782005STANDARDPRACTICEFORASSESSMENTOFRESISTANCEOFMEDICALGLOVESTOPERMEATIONBYCHEMOTHERAPYDRUGS

链接地址:http://www.mydoc123.com/p-524138.html