ASTM D6920-2003 Standard Test Method for Total Sulfur in Naphthas Distillates Reformulated Gasolines Diesels Biodiesels and Motor Fuels by Oxidative Combustion and Electrochemical .pdf
《ASTM D6920-2003 Standard Test Method for Total Sulfur in Naphthas Distillates Reformulated Gasolines Diesels Biodiesels and Motor Fuels by Oxidative Combustion and Electrochemical .pdf》由会员分享,可在线阅读,更多相关《ASTM D6920-2003 Standard Test Method for Total Sulfur in Naphthas Distillates Reformulated Gasolines Diesels Biodiesels and Motor Fuels by Oxidative Combustion and Electrochemical .pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6920 03An American National StandardStandard Test Method forTotal Sulfur in Naphthas, Distillates, ReformulatedGasolines, Diesels, Biodiesels, and Motor Fuels byOxidative Combustion and Electrochemical Detection1This standard is issued under the fixed designation D 6920; the number im
2、mediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 T
3、his test method covers the determination of total sulfurin liquid hydrocarbons, boiling in the range from approxi-mately 25 to 400C, with viscosities between approximately0.2 and 10 cSt (mm/S) at room temperature. This test methodis applicable to naphthas, distillates, and motor fuels such asgasolin
4、es, reformulated gasolines, gasohols, diesels and biodie-sels containing approximately 1 to 100 mg/kg total sulfur ingasoline type products, and approximately 1 to 40 mg/kg sulfurin diesel type products.1.2 The detector response for this technique within thescope of this test method is linear with s
5、ulfur concentration.1.3 Based on interlaboratory study, the pooled limit ofquantitation of this test method is 3 mg/kg for gasoline and900C) where oxygen is introduced. Sulfur compounds,present in the specimen are converted to sulfur dioxide (SO2).Sulfur dioxide is reacted with the sensing electrode
6、 in a3-electrode electrochemical cell. This reaction produces ameasurable current that is directly proportional to the amountof sulfur in the original sample material. The reactions thatoccur are as follows:Combustion:R-S+O2.900CCO2+H2O+SO2+ oxides1This test method is under the jurisdiction of ASTM
7、Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.03 on Elemental Analysis.Current edition approved Sept. 10, 2003. Published September 2003.2Annual Book of ASTM Standards, Vol 05.02.3Annual Book of ASTM Standards, Vol 05.03.4Annual Book of ASTM St
8、andards, Vol 06.04.5Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Detection:SO2+2H2OElectrolyte
9、H2SO4+2H+2e5. Significance and Use5.1 All sulfur present in petroleum products is converted tosulfur oxides upon combustion, which is a significant pollutantof the atmosphere. This test method can be used to monitor thetotal sulfur levels in these fuels.NOTE 1Virtually all sulfur compounds will be d
10、etected by thistechnique.6. Interferences6.1 Moisture produced during the combustion step caninterfere if not removed prior to the detector.6.2 Equivalent amounts of nitrogen in the sample may alsointerfere.7. Apparatus7.1 Pyrolysis Furnace, a furnace capable of maintaining atemperature sufficient t
11、o volatilize and combust all of thesample and oxidize the sulfur to SO2. The furnace temperaturesfor petroleum substances shall be as recommended by themanufacturer.7.2 Quartz Combustion Tube, capable of withstanding 900to 1200C. The inlet end of the tube holds a septum for syringeentry of the sampl
12、e and has inlet fittings or side arms for theintroduction of oxygen (O2) and inert gas. The construction issuch that the inert gas (or inert gas and oxygen mixture) sweepsthe inlet zone transporting all of the volatilized sample into ahigh temperature oxidation zone. The oxidation section shallbe la
13、rge enough to ensure complete oxidation of the sample.7.3 Drier TubeThe reaction products include water vaporthat must be removed prior to measurement by the electro-chemical detector. This can be accomplished with a magne-sium perchlorate scrubber or a membrane drying tube (perme-ation drier), or b
14、oth.7.4 Electrochemical Detector, capable of measuring SO2inthe combustion gas stream.7.5 Data Reduction System, having the capability of mea-suring, amplifying, and integrating the current from the elec-trochemical detector. The amplified or integrated output signalshall be applied to a digital dis
15、play or some other data reportingdevice.7.6 Microlitre Syringe, of 5, 10, 25, 50, or 100 L capacitycapable of accurately delivering microlitre quantities is re-quired. The needle should be long enough to reach the hottestportion of the inlet section of the furnace when injecting thesample.7.7 Record
16、er (Optional).7.8 Constant Rate Injector or Automatic Sampler System(s)(Optional), capable of delivering a sample at a preciselycontrolled rate.8. Reagents8.1 Purity of ChemicalsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall confo
17、rm to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,6where such specifications are available. Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the
18、 determination.8.2 Magnesium Perchlorate, Mg(ClO4)2(WarningMagnesium perchlorate is a strong oxidizer, and is an irritant)for drying products of the combustion (if a permeation drier isnot used).8.3 Inert GasEither argon (Ar) or helium (He) may beused. The purity should be no less than 99.99 mol %.8
19、.4 OxygenThe purity should be no less than 99.99 mol %(WarningOxygen of this purity will vigorously acceleratecombustion).8.5 SolventThe solvent chosen should be capable ofdissolving the sulfur-containing compound used to prepare thestandard and, if necessary, the samples. The solvent of choiceshoul
20、d have a boiling point similar to the samples beinganalyzed and it should contain less sulfur than is in the lowestsample to be analyzed. Suggested possibilities include, but arenot limited to: toluene, iso-octane, methanol, cetane, or othersolvent similar to the compound present in the sample to be
21、analyzed (WarningFlammable solvents).NOTE 2A quick screening can be conducted by injecting the solventand sample once or twice and comparing relative integral response.8.6 Sulfur Stock Solution, 1000 g S/mLPrepare a stocksolution by accurately weighing to the nearest 0.1 mg, 0.576 gof dibenzothiophe
22、ne into a tared 100-mL volumetric flask.Dilute to volume with selected solvent. This stock may befurther diluted to desired sulfur concentrations.g S/mL 5 (1)exact weight of dibenzothiophene mg!332.06 3 1000 g/mg!100 mL 3 184.27NOTE 3Dibenzothiophene may be used for calibration throughout theboiling
23、 range of this test method.8.7 Dibenzothiophene (C12H8S), CAS 132650(WarningDibenzothiophene is an irritant) molecular weight184.27, purity 99.8 %.8.8 Sulfur Working Standard Solutions, 0.5, 1.0, 10.0, and100.0 g S/mLThe working standards are prepared byaccurately pipetting and diluting each to volu
24、me with solvent.To obtain the following concentrations 100.0, 10.0, 1.0, and 0.5g S/mL see Table 1.6Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Annual
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD69202003STANDARDTESTMETHODFORTOTALSULFURINNAPHTHASDISTILLATESREFORMULATEDGASOLINESDIESELSBIODIESELSANDMOTORFUELSBYOXIDATIVECOMBUSTIONANDELECTROCHEMICALPDF

链接地址:http://www.mydoc123.com/p-523982.html