ASTM D6904-2003(2007) Standard Practice for Resistance to Wind-Driven Rain for Exterior Coatings Applied on Masonry《砌筑体外涂层耐风雨的标准实用规程》.pdf
《ASTM D6904-2003(2007) Standard Practice for Resistance to Wind-Driven Rain for Exterior Coatings Applied on Masonry《砌筑体外涂层耐风雨的标准实用规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6904-2003(2007) Standard Practice for Resistance to Wind-Driven Rain for Exterior Coatings Applied on Masonry《砌筑体外涂层耐风雨的标准实用规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6904 03 (Reapproved 2007)Standard Practice forResistance to Wind-Driven Rain for Exterior CoatingsApplied on Masonry1This standard is issued under the fixed designation D 6904; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is for the evaluation of the ability ofcoatings to resist the passage of water thr
3、ough masonry blockwhen exposed to water spray and air pressure.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does
4、 not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Stand
5、ards:2D 1475 Test Method For Density of Liquid Coatings, Inks,and Related ProductsD 3924 Specification for Environment for Conditioning andTesting Paint, Varnish, Lacquer, and Related MaterialsD 3925 Practice for Sampling Liquid Paints and RelatedPigmented Coatings2.2 Federal Standard:TT-C-555B Coat
6、ing, Textured (For Interior and ExteriorMasonry Surfaces)33. Summary of Practice3.1 Typically 8 by 16 by 2 in. masonry blocks are coatedwith block filler and then coated with the masonry paint andallowed to cure. The coated blocks are then secured to a testapparatus and exposed for 24 h to continuou
7、s water spray andair pressure or as agreed upon between manufacturer andsupplier. Upon completion of the exposure, the blocks areremoved, evaluated for visible water leaks or weight gain, orboth.4. Significance and Use4.1 This practice is meant to simulate the ability of a coatingsystem applied to a
8、 masonry block to withstand exposure tocontinuous water spray (rain) and a dynamic pressure equiva-lent to a 98 mph wind velocity without exhibiting water leaksor weight gain, or both.5. Apparatus5.1 The testing box is assembled from transparent plasticpanels12-in. thick and typically of the dimensi
9、ons as shown inFig. 1. Three openings on the side, 6 by 12 in., are provided sothat the coated side of the three blocks may be positioned fortest. The openings on the top of the apparatus for the air inletand manometer connection shall not be less than 3 in. apart tomake certain that air inlet turbu
10、lence will not effect themanometer readings. A spray tube shall be constructed from12-in. plastic tubing with three fish-tail nozzles.4Attachment tothe testing box includes a water-filled U-tube manometer,source of compressed air, clamps and angle irons for securelyfastening the test panels to the b
11、ox, and a drain outlet. Also,illustrated is a simple air pressure regulator consisting of aT-tube with the leg (foot) of the tube placed in a water filledbeaker at a depth of slightly greater than 5 in. This set up is alsoa safety device. Any sudden increase in air pressure will bevented harmlessly.
12、 The apparatus outlined above was derivedfrom that shown in Federal Specification TT-C-555B. Appara-tus and substrates of other dimensions can be used as agreedupon between manufacturer and supplier. The duration ofexposure and water pressure used will also be agreed uponbetween manufacturer and use
13、r.6. Reagents and Materials6.1 Three 8 by 16 by 2 in. Patio Blocks.6.2 Stiff Bristle Brush.6.3 Mortite or Rubber Gasket, to assure a tight fit of thepatio blocks to the test apparatus.1This practice is under the jurisdiction of ASTM Committee D01 on Paint andRelated Coatings, Materials, and Applicat
14、ions and is the direct responsibility ofSubcommittee D01.47 on Concrete, Stone and Masonry Treatments.Current edition approved Nov. 1, 2007. Published November 2007. Originallyapproved in 2003. Last previous edition approved in 2003 as D 6904 - 03.2For referenced ASTM standards, visit the ASTM websi
15、te, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SD
16、E, Washington, DC 20401, http:/www.access.gpo.gov.4Federal Specification TT-C-555B, Amendment No. 1, dated August 5, 1975,U.S. Government Printing Office.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.4 Clamps and Angle Irons.6.5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD690420032007STANDARDPRACTICEFORRESISTANCETOWINDDRIVENRAINFOREXTERIORCOATINGSAPPLIEDONMASONRY 砌筑

链接地址:http://www.mydoc123.com/p-523933.html