ASTM D6902-2004(2017) 5625 Standard Test Method for Laboratory Measurement of Formaldehyde Evolved During the Curing of Melamine-Formaldehyde-Based Coatings《蜜胺-甲醛基涂层在固化过程中实验室测量甲醛含量.pdf
《ASTM D6902-2004(2017) 5625 Standard Test Method for Laboratory Measurement of Formaldehyde Evolved During the Curing of Melamine-Formaldehyde-Based Coatings《蜜胺-甲醛基涂层在固化过程中实验室测量甲醛含量.pdf》由会员分享,可在线阅读,更多相关《ASTM D6902-2004(2017) 5625 Standard Test Method for Laboratory Measurement of Formaldehyde Evolved During the Curing of Melamine-Formaldehyde-Based Coatings《蜜胺-甲醛基涂层在固化过程中实验室测量甲醛含量.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6902 04 (Reapproved 2017)Standard Test Method forLaboratory Measurement of Formaldehyde Evolved Duringthe Curing of Melamine-Formaldehyde-Based Coatings1This standard is issued under the fixed designation D6902; the number immediately following the designation indicates the year oforig
2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is for the determination of formalde-hyde evol
3、ved from melamine-formaldehyde-based coatingsduring the cure step. The results may be used to determine the“cure formaldehyde” evolved from a sample under controlledlaboratory conditions.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for info
4、rmationonly.1.3 This test method is capable of measuring from 500 g/gto 22 000 g formaldehyde/g dry coating under the testconditions specified (3 000 ml/min total flow, 50 ml/minDNPH tube flow). The ratio of total flow to DNPH tube flowcould be adjusted to extend the range of the method.1.4 This sta
5、ndard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This in
6、ternational standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT
7、) Committee.2. Referenced Documents2.1 ASTM Standards:2D362 Specification for Industrial Grade Toluene (Withdrawn1989)3D1979 Test Method for Free Formaldehyde Content ofAmino Resins (Withdrawn 2006)3D6191 Test Method for Measurement of Evolved Formalde-hyde from Water Reducible Air-Dry CoatingsE691
8、Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 cure formaldehyde, nthe formaldehyde generated asthe result of a chemical reaction during coating curing.3.1.2 free formaldehyde, nthe res
9、idual formaldehyde in acoating due to the raw materials.4. Summary of Test Method4.1 Approximately 0.2 g of coating formulation is placed inan aluminum foil pan, dried in a vacuum oven at 40C (toremove free formaldehyde and solvents) and then baked at theoptimum process cure temperature for 30 min.
10、Formaldehydeemissions are collected from the cure chamber on a DNPH/Silica tube, which is then extracted and the extract analyzed byHPLC/UV. The amount of formaldehyde evolved from thecoating during the cure step is calculated on both a wet-weightand dry-weight basis. The test is run in triplicate p
11、lus a blankand system standard.5. Significance and Use5.1 This test method measures the amount of formaldehydethat is evolved from a coating containing melamine-formaldehyde resin(s) during cure at elevated temperature.Cure formaldehyde results from a side-reaction during cross-linking of functional
12、ized polymers with melamine-formaldehyde resins. Cure formaldehyde is evolved in the finalbake or cure oven, when the coating temperature is highenough to initiate cross-linking. Formaldehyde can be releasedfrom a coating during application, solvent flash-off and cure.Free formaldehyde is primarily
13、evolved during coating appli-cation and solvent flash-off. Test Method D1979 measures“free formaldehyde” in amino resins and Test Method D6191measures formaldehyde evolved from coatings at ambienttemperature. This method measures only the formaldehydereleased during heat cure, which is primarily “cu
14、re formalde-hyde.”1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved Dec. 1, 2017. Published Dec
15、ember 2017. Originallyapproved in 2003. Last previous edition approved in 2011 as D6902 04 (2011).DOI: 10.1520/D6902-04R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, re
16、fer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed
17、 in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.15.2 This test method is
18、 not intended to duplicate the evolvedformaldehyde from an industrial process, but serves as areproducible comparative laboratory evaluation.5.3 This test method has not been evaluated with catalyzedcoating systems that cure at or below 40C, such as those usedby the wood-finishing industry, and woul
19、d likely requirespecial adaptation for this application.6. Apparatus6.1 High Pressure Liquid Chromatograph (HPLC), either agradient or isocratic system. A gradient system is preferredwhen other aldehydes or ketones are present.NOTE 1The system shall be equipped with a temperature-controlledcolumn ov
20、en. A liquid autosampler is optional.6.2 Column, aC18ODS packed with 5-m pellicular beadswith the dimensions of approximately 4 mm by 75 or 150 mm.A 2-cm guard column packed with the same material isrecommended to protect the analytical column.6.3 Detector, UV/VIS detector capable of measuring absor
21、-bance at 360 nm.6.4 Integrator, peak integration system.6.5 Air Sampling Pump, an air sampling pump with thecapability of maintaining a constant flow rate between 3 and 4L/min. Both an inlet and outlet port must be available formeasuring flow. An SKC AirCheck Sampler Model 224-PCXR8 has been found
22、suitable.6.6 Flow MetersAn in-line mass flow meter or flowsensor capable of measuring 30 to 120 mL/min with at least3 % accuracy. A flow meter or bubble meter capable ofmeasuring 3 to 4 L/min with at least 5 % accuracy.6.7 Glass Purge ChamberA glass purge chamber with amouth at least 60 mm wide and
23、a lid with an air-tight gasketseal. One liter reaction flask, reaction flask head with twothreads, two 5029 tetrafluorethylene polymer bushings andFETFE O-Ring and 124 mm anodized 2 piece clamp, AceGlass part numbers 6511-53, 6513-SP, and 6508-6.6.8 ValvesTwo metering valves to adjust split flow rat
24、e.One valve must be constructed of stainless steel. A Swagelok506-1-316 has been found suitable.6.9 Aluminum Foil Dishes, 58 mm in diameter by 18 mmhigh with a smooth (planar) bottom surface.6.10 Forced Draft Oven, oven, capable of maintaining160C (320F), of adequate size to accommodate one or morep
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6902200420175625STANDARDTESTMETHODFORLABORATORYMEASUREMENTOFFORMALDEHYDEEVOLVEDDURINGTHECURINGOFMELAMINEFORMALDEHYDEBASEDCOATINGS

链接地址:http://www.mydoc123.com/p-523929.html