《ASTM D6892-2003(2008) 752 Standard Test Method for Pour Point of Petroleum Products (Robotic Tilt Method)《石油产品倾点的标准试验方法(自动倾斜法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6892-2003(2008) 752 Standard Test Method for Pour Point of Petroleum Products (Robotic Tilt Method)《石油产品倾点的标准试验方法(自动倾斜法)》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6892 03 (Reapproved 2008)An American National StandardStandard Test Method forPour Point of Petroleum Products (Robotic Tilt Method)1This standard is issued under the fixed designation D 6892; the number immediately following the designation indicates the year oforiginal adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the pourpoint of petroleum products
3、by an automatic instrument thattilts the test jar to detect movement of the surface of the testspecimen with an optical device, after being removed from aregulated, stepped-bath cooling jacket.1.2 This test method is designed to cover the range oftemperatures from 57 to +51C; however, the range ofte
4、mperatures included in the 1998 interlaboratory test programonly covered the temperature range from 51 to 11C.1.3 Test results from this test method can be determined ateither 1 or 3C testing intervals.1.4 This test method is not intended for use with crude oils.NOTE 1The applicability of this test
5、method on residual fuel sampleshas not been verified. For further information on the applicability, refer to13.4.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety
6、concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D97 Test Method for Pour Point of P
7、etroleum ProductsD 4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD 4177 Practice for Automatic Sampling of Petroleum andPetroleum Products2.2 Energy Institute Standard:3IP 15 Test Method for Pour Point of Petroleum Products3. Terminology3.1 Definitions:3.1.1 pour point, nin pet
8、roleum products, the lowesttemperature at which movement of the test specimen isobserved under prescribed conditions of test.3.2 Definitions of Terms Specific to This Standard:3.2.1 no-flow point, nin petroleum products, the tempera-ture of the test specimen at which a wax crystal structure orviscos
9、ity increase, or both, impedes movement of the surfaceof the test specimen under the conditions of the test.3.2.1.1 DiscussionThe no-flow point occurs when, uponcooling, the formation of wax crystal structures or viscosityincrease, or both, has progressed to the point where the appliedobservation de
10、vice no longer detects movement under theconditions of the test. The preceding observation temperatureat which flow of the test specimen is last observed is the pourpoint.3.2.2 tilting, vttechnique of movement where the test jarin a vertical position is moved towards a horizontal position toinduce s
11、pecimen movement.3.2.2.1 DiscussionWhen the test jar is tilted and held in ahorizontal position for 5 s without detection of movement ofthe surface of the specimen, this is the no-flow point and thetest is complete.4. Summary of Test Method4.1 After insertion of the specimen into the automatic pourp
12、oint apparatus and initiation of the testing program, thespecimen is heated and then cooled according to a prescribedprofile. The specimen surface is examined periodically formovement using an optical camera system mounted on top ofthe specimen test jar, while tilting the specimen test jar. Thetest
13、jar is removed from the jacketed cooling chamber prior toeach examination. The lowest temperature, when movement ofthe surface of the specimen is detected, is recorded as the pourpoint determined by this Test Method D 6892.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum
14、 Products and Lubricants and is the direct responsibility of SubcommitteeD02.07 on Flow Properties.Current edition approved Dec. 15, 2008. Published February 2009.Originallyapproved in 2003. Last previous edition approved in 2003 as D 689203.2For referenced ASTM standards, visit the ASTM website, ww
15、w.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Energy Institute, 61 New Cavendish St., London, WIG 7AR,U.K., http:/www.energyinst.org.uk.1Copyright AS
16、TM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Significance and Use5.1 The pour point of a petroleum product is an index of thelowest temperature of its utility for certain applications. Flowcharacteristics, such as pour point, can be critica
17、l for thecorrect operation of lubricating systems, fuel systems, andpipeline operations.5.2 Petroleum blending operations require precise measure-ment of the pour point.5.3 Test results from this test method can be determined ateither 1 or 3C intervals.5.4 This test method yields a pour point in a f
18、ormat similarto Test Method D97or IP 15, when the 3C interval results arereported.NOTE 2Since some users may wish to report their results in a formatsimilar to Test Method D97or IP 15 (in 3C intervals) the precision datawere derived for the 3C intervals. For statements on bias relative to TestMethod
19、 D97or IP 15, see the research report.5.5 This test method has comparable repeatability and betterreproducibility relative to Test Method D97 or IP 15 asmeasured in the 1998 interlaboratory program (see Section 13).6. Apparatus6.1 Automatic Apparatus4The automatic pour point appa-ratus described in
20、this test method (see Fig. 2) consists of amicroprocessor controlled measuring unit that is capable ofheating the specimen to programmed temperatures, cooling thespecimen according to programmed cooling profiles, mechani-cally manipulating the test jar according to the programmedtest procedure, whil
21、e optically observing the surface of thespecimen for movement, using a camera system mounted ontop of the specimen test jar and recording the temperature ofthe specimen. The apparatus shall be equipped with a userinterface, cooling/heating block assembly with cylindricaljacket with an inside diamete
22、r of 44.2 to 45.8 mm, and about115 mm in depth to accept the test jar) robotic mechanisms forlifting, tilting, replacing the test jar, optical camera system, anda temperature measuring device.6.2 Test JarClear, cylindrical glass, flat bottom (dark-ened), 31.5 6 0.5 mm inside diameter and 120 6 2 mm
23、heightwith a wall thickness of 1.25 6 0.25 mm. The jar shall bemarked with a line to indicate sample filling height correspond-ing to 45 6 0.5 mL.6.3 Temperature ProbeCapable of measurement from +70to 80C with a resolution of 0.1C. The temperature probeshall be suspended in the center axis of the te
24、st jar and the topof the temperature sensing zone immersed below the surface ofthe specimen.6.4 Circulating BathRefrigeration unit, equipped with acirculating pump, capable of maintaining the liquid cooling4The sole source of supply of the Herzog Model MP 852 or HCP 852 known tothe committee at this
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD689220032008752STANDARDTESTMETHODFORPOURPOINTOFPETROLEUMPRODUCTSROBOTICTILTMETHOD 石油 产品 标准 试验 方法

链接地址:http://www.mydoc123.com/p-523902.html