《ASTM D6889-2003(2011) 1250 Standard Practice for Fast Screening for Volatile Organic Compounds in Water Using Solid Phase Microextraction (SPME)《用固相微萃取法(SPME)快速筛选水中挥发性有机化合物的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6889-2003(2011) 1250 Standard Practice for Fast Screening for Volatile Organic Compounds in Water Using Solid Phase Microextraction (SPME)《用固相微萃取法(SPME)快速筛选水中挥发性有机化合物的标准操作规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6889 03 (Reapproved 2011)Standard Practice forFast Screening for Volatile Organic Compounds in WaterUsing Solid Phase Microextraction (SPME)1This standard is issued under the fixed designation D6889; the number immediately following the designation indicates the year oforiginal adoptio
2、n or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a procedure for the screening oftrace levels of volati
3、le organic compounds in water samples byheadspace solid phase microextraction (SPME) in combinationwith fast gas chromatography with flame ionization detection.1.2 The results from this screening procedure are used toestimate analyte concentrations to prevent contamination ofpurge and trap or headsp
4、ace analytical systems.1.3 The compounds of interest must have a greater affinityfor the SPME absorbent polymer or adsorbent than the samplematrix or headspace phase in which they reside.1.4 Not all of the analytes which can be determined bySPME are addressed in this practice. The applicability of t
5、heabsorbent polymer, adsorbent or combination to extract thecompound(s) of interest must be demonstrated before use.1.5 Where used it is the responsibility of the user to validatethe application of SPME to the analytes of interest.1.6 The values stated in SI units are to be regarded asstandard. No o
6、ther units of measurement are included in thisstandard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility
7、 of regulatory limitations prior to use. For specific hazardstatements, see Section 9.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD3694 Practices for Preparation of Sample Containers andfor Preservation of Organic ConstituentsD38
8、56 Guide for Good Laboratory Practices in Laborato-ries Engaged in Sampling and Analysis of WaterD4210 Practice for Intralaboratory Quality Control Proce-dures and a Discussion on Reporting Low-Level Data3D6520 Practice for the Solid Phase Micro Extraction(SPME) of Water and its Headspace for the An
9、alysis ofVolatile and Semi-Volatile Organic Compounds3. Summary of Practice3.1 This practice employs adsorbent/gas extraction to iso-late compounds of interest, see Practice D6520. An aqueoussample is added to a small (2 mL) septum sealed vial. Salt isused to improve analyte recovery. After the addi
10、tion of asurrogate standard and a short mixing cycle, a SPME fusedsilica fiber coated with a thick polymer film is then exposed tothe aqueous headspace for a few seconds. The fiber is thendesorbed in the heated injection port of a GC/FID or GC-MSand the resulting analytes chromatographed on a short
11、narrowbore capillary column. The total analysis time is approximately3 min.3.2 The concentrations of the volatile organics in the watersample are estimated to determine whether the sample may beanalyzed directly or first diluted prior to purge and trap orheadspace analysis.4. Significance and Use4.1
12、 This practice provides a general procedure for thesolid-phase microextraction (SPME) of volatile organic com-pounds from the headspace of an aqueous matrix. Absorbentextraction is used as the initial step in the extraction of organicconstituents for the purpose of screening and subsequentlyestimati
13、ng the concentration of the volatile organic compo-nents found in water samples. This information may then beused to determine whether a sample may be analyzed directlyby purge and trap or headspace or will require dilution prior toanalysis.4.2 Typical detection limits that can be achieved usingSPME
14、 techniques with gas chromatography (GC) with a flameionization detector (FlD) range from milligrams per litre(mg/L) to micrograms per litre (g/L). The detection limit,1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.06 on Me
15、thods for Analysis forOrganic Substances in Water.Current edition approved May 1, 2011. Published June 2011. Originallyapproved in 2003. Last previous edition approved in 2003 as D688903. DOI:10.1520/D6889-03R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Cus
16、tomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive,
17、PO Box C700, West Conshohocken, PA 19428-2959, United States.linear concentration range, and sensitivity of this test methodfor a specific organic compound will depend upon the aqueousmatrix, the fiber phase, the sample temperature, sample vol-ume, sample mixing, and the determinative technique em-p
18、loyed.4.3 Solid phase microextraction has the advantage of speed,reproducibility, simplicity, no solvent, small sample size, andautomation.4.3.1 Extraction devices vary from a manual SPME fiberholder to automated commercial devices specifically designedfor SPME.4.3.2 Apartial list of volatile organi
19、c compounds that can bescreened by this practice is shown in Table 1.5. Principles of SPME5.1 Solid phase microextraction is an equilibrium techniquewhere analytes are not completely extracted from the matrix.With liquid samples, the recovery is dependent on the parti-tioning or equilibrium of analy
20、tes among the three phasespresent in the sampling vial: the aqueous sample and headspace(Eq 1), the fiber coating and aqueous sample (Eq 2), and thefiber coating and the headspace (Eq 3):K15 CL/Cg(1)K25 CF/CL(2)K35 CF/CG(3)where:CL,CG, and CF= concentrations of the analyte in thesephases.5.1.1 Distr
21、ibution of the analyte among the three phases:C0VL5 CGVG1 CLVL1 CFVF(4)5.1.2 Concentration of analyte in fiber:CF5 C0VLK1K2/VG1 K1VL1 K1K2VF(5)6. Interferences6.1 Reagents, glassware, septa, fiber coatings and othersample processing hardware may yield discrete artifacts orelevated baselines that can
22、 cause poor precision and accuracy.See Terminology D1129.6.1.1 Plastics other than PTFE-fluorocarbon should beavoided. They are a significant source of interference and canadsorb some organics.7. Apparatus7.1 SPME Holder, manual or automated sampling.7.1.1 SPME Fiber AssemblyPolydimethylsiloxane(PDM
23、S), 30uM or equivalent fiber suitable for volatiles ad-sorption.7.2 Vials with Septa and Caps, for manual or automatedSPME. Vials for automation, 2 mL.7.3 Gas Chromatograph, with flame ionization detector.7.3.1 GC Column, 10 m by 0.25 mm, 1uM film MethylSilicone, or equivalent.7.3.2 GC Guard Column,
24、 1m by 0.32 mm uncoated, orequivalent.7.3.3 Split/splitless Injector, with 0.75 to 1.0 mm insidediameter insert.7.3.4 Optional Septum Replacement Device.7.3.5 Optional SPME Autosampler.7.3.6 GC Compatible Workstation.8. Reagents8.1 Purity of WaterUnless otherwise indicated, referenceto water shall b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6889200320111250STANDARDPRACTICEFORFASTSCREENINGFORVOLATILEORGANICCOMPOUNDSINWATERUSINGSOLIDPHASEMICROEXTRACTIONSPME

链接地址:http://www.mydoc123.com/p-523870.html