ASTM D6888-2016 red 7029 Standard Test Method for Available Cyanides with Ligand Displacement and Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric .pdf
《ASTM D6888-2016 red 7029 Standard Test Method for Available Cyanides with Ligand Displacement and Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric .pdf》由会员分享,可在线阅读,更多相关《ASTM D6888-2016 red 7029 Standard Test Method for Available Cyanides with Ligand Displacement and Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric .pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6888 09D6888 16Standard Test Method forAvailable CyanideCyanides with Ligand Displacement andFlow Injection Analysis (FIA) Utilizing Gas DiffusionSeparation and Amperometric Detection1This standard is issued under the fixed designation D6888; the number immediately following the design
2、ation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This method is used to determine
3、 the concentration of available inorganic cyanide in an aqueous wastewater or effluent. Themethod detects the cyanides that are free (HCN and CN-) and metal-cyanide complexes that are easily dissociated into free cyanideions. The method does not detect the less toxic strong metal-cyanide complexes,
4、cyanides that are not “amenable to chlorination.”1.2 Total cyanide can be determined for samples that have been distilled as described in Test Methods D2036, Test Method A,Total Cyanides after Distillation. The cyanide complexes are dissociated and absorbed into the sodium hydroxide capture solution
5、,which can be analyzed with this test method; therefore, ligand exchange reagents from Sections 8.12 and 8.13 would not berequired when determining total cyanide after distillation.1.3 This procedure is applicable over a range of approximately 2 to 400 g/L (parts per billion) available cyanide.cyani
6、des.Higher concentrations can be analyzed by dilution or lower injection volume.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated w
7、ith its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. Specific hazard statements are given in Note 28.6 and Section 9.2. Referenced Documents2.1 ASTM Standards:2D11
8、29 Terminology Relating to WaterD1193 Specification for Reagent WaterD2036 Test Methods for Cyanides in WaterD2777 Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on WaterD3856 Guide for Management Systems in Laboratories Engaged in Analysis of WaterD4375
9、 Practice for Basic Statistics in Committee D19 on WaterD5847 Practice for Writing Quality Control Specifications for Standard Test Methods for Water AnalysisD6696 Guide for Understanding Cyanide SpeciesD7365 Practice for Sampling, Preservation and Mitigating Interferences in Water Samples for Analy
10、sis of CyanideE60 Practice for Analysis of Metals, Ores, and Related Materials by SpectrophotometryE275 Practice for Describing and Measuring Performance of Ultraviolet and Visible Spectrophotometers3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this standard, refer to Terminol
11、ogy D1129 and Guide D6696.3.2 Definitions:Definitions of Terms Specific to This Standard:3.1.1 For definitions of terms used in this test method, refer to Terminology D1129 and Guide D6696.1 This test method is under the jurisdiction of ASTM Committee D19 on Water and is the direct responsibility of
12、 Subcommittee D19.06 on Methods for Analysis forOrganic Substances in Water.Current edition approved Oct. 1, 2009Feb. 1, 2016. Published October 2009June 2016. Originally approved in 2003. Last previous addition approved in 20042009 asD6888 04.D6888 09. DOI: 10.1520/D6888-09.10.1520/D6888-16.2 For r
13、eferencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provid
14、e the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the st
15、andard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.1 available cyanide,cyanides, nInorganic cyanides that are free (HCN and CN-) and metal-cyanide complexes that a
16、reeasily dissociated into free cyanide ions. Available cyanide does not include the less toxic strong metal-cyanide complexes,cyanides that are not “amenable to chlorination.”3.2.1.1 DiscussionAvailable cyanide does not include the less toxic strong metal-cyanide complexes, cyanides that are not “am
17、enable to chlorination”and includes weak acid dissociable or weak and dissociable (WAD) cyanides for use in the implementation of InternationalCyanide Management Code.4. Summary of Test Method4.1 Complex cyanides bound with nickel or mercury are released by ligand displacement by the addition of a l
18、iganddisplacement agent prior to analysis.agent, when necessary.4.2 Other weak and dissociable cyanide species do not require ligand displacement.4.3 The treated sample is introduced into a flow injection analysis (FIA) system where it is acidified to form hydrogen cyanide(HCN). The hydrogen cyanide
19、 gas diffuses through a hydrophobic gas diffusion membrane, from the acidic donor stream into analkaline acceptor stream.4.4 The captured cyanide is sent to an amperometric flowcell detector with a silver-working electrode. In the presence ofcyanide, silver in the working electrode is oxidized at th
20、e applied potential. The anodic current measured is proportional to theconcentration of cyanide in the standard or sample injected.4.5 Calibrations and data are processed with the instruments data acquisition software.5. Significance and Use5.1 Cyanide and hydrogen cyanide are highly toxic. Regulati
21、ons have been established to require the monitoring of cyanide inindustrial and domestic wastes and surface waters.35.2 This test method is applicable for natural water, saline waters, metallurgical process solutions, and wastewater effluent.5.3 The method may be used for process control in wastewat
22、er treatment facilities.6. Interferences6.1 High levels of carbonate can release CO2 into the acceptor stream and cause an interference with the amperometric detectorthat result in a slight masking effect (15 % negative bias with 20 ppb cyanide in 1500 ppm carbonate). Refer to 11.2 for samplepretrea
23、tment.6.2 Sulfide above 50 mg/L will diffuse through the gas diffusion membrane and can be detected in the amperometric flowcell.Oxidized products of sulfide can also rapidly convert CN- to SCN- at a high pH. Refer to Practice D7365 for sulfide removalprocedures.6.3 Refer to Practice D7365 for furth
24、er information on mitigating interferences in water samples for the analysis of cyanide.7. Apparatus7.1 The instrument should be equipped with a precise sample introduction system, a gas diffusion manifold with hydrophobicmembrane, and an amperometric detection system to include a silver working ele
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD68882016RED7029STANDARDTESTMETHODFORAVAILABLECYANIDESWITHLIGANDDISPLACEMENTANDFLOWINJECTIONANALYSISFIAUTILIZINGGASDIFFUSIONSEPARATIONANDAMPEROMETRICPDF

链接地址:http://www.mydoc123.com/p-523868.html