ASTM D6845-2002 Standard Test Method for Silica Precipitated Hydrated&8212 CTAB (Cetyltrimethylammonium Bromide) Surface Area《沉淀的水合硅石的标准试验方法 溴化十六烷基三甲铵(CTAB)表面区域》.pdf
《ASTM D6845-2002 Standard Test Method for Silica Precipitated Hydrated&8212 CTAB (Cetyltrimethylammonium Bromide) Surface Area《沉淀的水合硅石的标准试验方法 溴化十六烷基三甲铵(CTAB)表面区域》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6845-2002 Standard Test Method for Silica Precipitated Hydrated&8212 CTAB (Cetyltrimethylammonium Bromide) Surface Area《沉淀的水合硅石的标准试验方法 溴化十六烷基三甲铵(CTAB)表面区域》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6845 02Standard Test Method forSilica, Precipitated, HydratedCTAB(Cetyltrimethylammonium Bromide) Surface Area1This standard is issued under the fixed designation D 6845; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of the specificsurface area of precipitated silicas exclusive
3、of area containedin micropores too small to admit hexadecyltrimethylammo-nium bromide (cetyltrimethylammonium bromide, commonlyreferred to as CTAB) molecules. This test method is suitablefor characterizing rubber-grade silicas of all types.1.2 The values stated in SI units are to be regarded as thes
4、tandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the appl
5、ica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 1193 Specification for Reagent Water2D 1799 Practice for Carbon BlackSampling PackagedShipments3D 1900 Practice for Carbon BlackSampling Bulk Ship-ments3D 4483 Practice for Determining Precision for Test Me
6、thodStandards in the Rubber and Carbon Black Industries33. Summary of Test Method3.1 The isotherm for adsorption of an aqueous solution ofCTAB on silicas has a long horizontal plateau corresponding toa monolayer coverage of the substrate surface from which theadsorbate is not sterically excluded. Th
7、e CTAB adsorption bysilica is independent of functional groups containing hydrogenand oxygen, etc. Rapid equilibration is achieved by usingmechanical stirring. Titration with dioctyl sodium sulfosucci-nate (Aerosol OT4) solution to a turbidity maximum end pointis used to determine the unadsorbed CTA
8、B after removal of thecolloidally dispersed silica by ultrafiltration.3.2 Titration of the unadsorbed CTAB with Aerosol OTsolution is accomplished by automatic titration.4. Significance and Use4.1 The CTAB molecule is relatively large; so it is notadsorbed in micropores or on surface roughness. Thus
9、, theCTAB surface area reflects only the surface of the silica that isavailable for interaction with rubber molecules.5. Apparatus5.1 Analytical Balance, 0.1 mg sensitivity.5.2 Centifuge, capable of 67 rev/s (4000 r/m).5.3 Magnetic Spinbars,5chemically resistant covered (poly-chlorotrifluoroethylene
10、 or TFE-fluorocarbon), 6.4- or 4.8-mm(14-or316-in.) diameter, and length nearly equal to thediameter of 50 or 100 cm3Berzelius beakers, glass vials, orother glass vessels.5.4 Glass Funnel, small.5.5 Glass Vials, with plastic screw caps, 28 mm in outsidediameter, about 40 cm3capacity.5.6 Buret,50cm3,
11、 0.1 cm3divisions, Class A, preferably ofautomatic refilling and zeroing type (see Note 1) with reagentreservoir.NOTE 1Automatic burets are usually not certified to Class A toler-ance. Such burets should be checked for accuracy, and if in error by morethan 0.05 cm3at any point, a calibration curve s
12、hould be prepared andused to correct observed buret readings. Burets with TFE-fluorocarbonmanostat valves offer some advantage in ease of stopcock manipulation indelivering small increments of titrant.5.7 Dispenser-Type Pipet,650 cm3, attached to a suitablereservoir for CTAB solution.1This test meth
13、od is under the jurisdiction of ASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.20 on Compounding Materialsand Procedures.Current edition approved Dec. 10, 2002. Published December 2002. Originallyapproved in 2002. Last previous edition approved in 2002 as D 6845 02.
14、2Annual Book of ASTM Standards, Vol 11.01.3Annual Book of ASTM Standards, Vol 09.01.4Aerosol OT is a registered trademark of the American Cyanamid Co., ProcessChemicals Dept., Wayne, NM 07470.5Examples of suitable spinbars are Catalog No. 9235-U7, A. H. Thomas Co.,Philadelphia, PA 19105, or Catalog
15、No. S-76497-30, Sargent Welch Scientific Co.,Skokie, IL 60076.6This test is based on the use of the Universal Repipet, a registered trademarkof Labindustries, 1802 Second St., Berkeley, CA 94710.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Unit
16、ed States.5.8 Pipet,10cm3, Class A.5.9 Erlenmeyer Flasks, or beakers, 50 or 100 cm3.5.10 Dropping Bottle,60cm3amber.5.11 Jar, wide-mouth, plastic screw cap, 120 or 240 cm3(4-or 8-oz) size.5.12 Gravity Convection Drying Oven, capable of maintain-ing 105 6 5C.5.13 Magnetic Stirrer.5.14 Containers, sui
17、table for preparation and storage ofreagent solutions.5.15 Automatic Titration Equipment with 550 nm Photo-probe,7with instruction manual.5.16 Beakers, 100 cm3Berzelius, tall form (one furnishedwith automatic titration equipment).5.17 Thermometer, to measure temperature in a range from20 to 40C.5.18
18、 Polyethylene Tubing (do not use vinyl tubing).NOTE 2All apparatus must be kept chemically clean. Contaminationof equipment, water supply, or chemicals by ionic surfactants must beparticularly avoided.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwis
19、e indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications are available.8Other grades may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permi
20、t its use without lessening the accuracy ofthe determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Type 1 in Specification D 1193.6.3 Sodium Hydroxide Solution (1M)Dissolve 40.0 gNaOH ina1dm3flask containing 0.5 dm3re
21、agent water. Afterdissolution fill to mark.6.4 Buffer Solution of pH 9.6 (0.05 M)Prepare buffersolution by dissolving 3.101 g of orthoboric acid (H3BO4),3.708 g of potassium chloride (KCl) and 36.85 cm3of sodiumhydroxide (NaOH) solution ina1dm3flask containing 0.5 dm3reagent water. After dissolution
22、 fill to mark. Verify that the pHof the solution is 9.6 6 0.1.6.5 CTAB Standard SolutionDissolve 5.5 g of reagent-grade CTAB9ina1dm3flask containing 350 dm3of buffersolution and 500 dm3water. After dissolution fill to mark.Homogenize on a magnetic stirrer for 10 h. Allow to stand 24h before use. Ver
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD68452002STANDARDTESTMETHODFORSILICAPRECIPITATEDHYDRATED8212CTABCETYLTRIMETHYLAMMONIUMBROMIDESURFACEAREA

链接地址:http://www.mydoc123.com/p-523759.html