《ASTM D6843-2010(2015) 6711 Standard Test Method for Silanes Used in Rubber Formulations (bis-(triethoxysilylpropyl)sulfanes) Characterization by Gas Chromatography (GC)《橡胶配方 (双-(三甲.pdf》由会员分享,可在线阅读,更多相关《ASTM D6843-2010(2015) 6711 Standard Test Method for Silanes Used in Rubber Formulations (bis-(triethoxysilylpropyl)sulfanes) Characterization by Gas Chromatography (GC)《橡胶配方 (双-(三甲.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6843 10 (Reapproved 2015)Standard Test Method forSilanes Used in Rubber Formulations(bis-(triethoxysilylpropyl)sulfanes): Characterization by GasChromatography (GC)1This standard is issued under the fixed designation D6843; the number immediately following the designation indicates the
2、 year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the characterization of sil
3、anesof the type bis-(triethoxysilylpropyl)sulfanes by gas chroma-tography.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its
4、use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4626 Practice for Calculation of Gas ChromatographicResponse FactorsE177
5、 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE355 Practice for Gas Chromatography Terms and Relation-shipsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 Definitions:3.1.1 PTESPropyltriethoxysilane CH3CH2CH2Si(
6、OEt)33.1.2 Cl-PTESChloropropyltriethoxysilane Cl-CH2CH2CH2Si(OEt)34. Summary of Test Method4.1 In this test method, a sample of the silane is analyzed bygas chromatography in order to determine the amount ofvolatile components. From the peak areas in thechromatogram, the percents by weight of volati
7、les are totaledand designated as the total volatile impurities or volatileby-products.5. Significance and Use5.1 The amount of volatile components reflects the impuritylevel in the product, and as a consequence, its behavior in arubber mixture.6. Apparatus6.1 Gas Chromatograph, equipped with:6.1.1 F
8、lame Ionization Detector (FID).6.1.2 Capillary Column, typical is 30 m length, 0.25 to 0.53mm internal diameter, fused silica, 0.1 to 1.0 m film thickness.6.1.3 Carrier Gas Flow Control, with splitter.6.1.4 Temperature Controls, for injector, detector and col-umn.6.2 Syringe, 1mm3(L).6.3 Analytical
9、Balance, accuracy 60.1 mg.6.4 Automatic Pipets, 0.2 to 1.0 cm3,5cm3.6.5 Sample Vials, approximately 15 cm3.7. Reagents7.1 Methanol, analytical grade (for cleaning syringe).7.2 Undecane,3analytical grade (used as internal standard).7.3 Optional: Cyclohexane, analytical grade (used to dilutethe sample
10、).7.4 Helium, minimum 99.99 % purity, suitable for chro-matographic use, dried (carrier gas).7.5 Hydrogen Gas, minimum 99.99 % purity, total hydro-carbons 1 ppm (for detector).1This test method is under the jurisdiction of ASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee
11、D11.20 on Compounding Materialsand Procedures.Current edition approved June 1, 2015. Published September 2015. Originallyapproved in 2002. Last previous edition approved in 2010 as D6843 10. DOI:10.1520/D6843-10R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM
12、Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Similar hydrocarbons like decane, analytical grade, can be used in place ofundecane, as long as they do not interfere with peaks from the sample.
13、Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17.6 Air, suitable for chromatographic use, total hydrocar-bons 2 ppm, moisture 3 ppm (for detector).8. Procedure8.1 Set up the gas chromatograph using the followingexample parameters as
14、a guide:Carrier gas He, linear velocity 20 to 50 cm/sSplit ratio 1:4 to 1:10Injectortemperature250COventemperatureTemperature program: for example,50C / 2 min6.5C/min260C / 15 minNOTE 1The above parameters can beadjustedas appropriate to match the column charac-teristics.For example, a more narrow c
15、olumn can usea fasterprogram (such as 50C for 1 min. hold/15C/min.ramp/300C for 15 min hold).Detectortemperature320CCombustion gas-sesH2, air as needed for FID8.2 Tare a sample vial (W1).8.3 Weigh 5 cm3of Bis-(triethoxysilylpropyl)sulfanes intothe tared sample vial (W2).8.4 Add 1 cm3undecane3(intern
16、al standard) and weighagain (W3).8.5 Homogenize the solution by shaking gently.NOTE 1Before injection, the sample may be diluted 1:5 withcyclohexane.8.6 Inject 0.5 mm3(L) of the neat sample or 1.0 mm3(L)of the diluted sample into the gas chromatograph and start themeasurement process.8.7 Clean the s
17、yringe immediately with methanol and dry.8.8 The measurement is finished when the base line isreached after a broad peak (indicative of the trisulfane species).Typically, a run takes less than 30 min.8.9 Allow the oven to cool down to the start temperature.The next measurement may be started as soon
18、 as the GCindicates a ready condition.9. Calculation9.1 The amount of each volatile component is calculated asfollows:I 5AiAstdW32 W2!W22 W1!RRi100 %# (1)where:I = weight per cent of component i in the testsample,Ai= peak area of component i,Astd= peak area of undecane3(internal standard),RRi= respo
19、nse factor of component i,(W3W2) = weight in g of undecane3(internal standard),and(W2W1) = weight in g of silane sample.9.2 All components with a retention time smaller or equal toCl-PTES are considered to be “volatile impurities” or “volatileby-products.” If the identity of a volatile component is
20、notknown, the response factor of Cl-PTES will be applied.9.3 See Table 1.10. Report10.1 Report the following information:10.1.1 Identification of the sample, and10.1.2 Volatile impurities to the nearest 0.1 weight %.11. Precision and Bias411.1 The precision of this test method is based on aninterlab
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6843201020156711STANDARDTESTMETHODFORSILANESUSEDINRUBBERFORMULATIONSBISTRIETHOXYSILYLPROPYLSULFANESCHARACTERIZATIONBYGASCHROMATOGRAPHYGC

链接地址:http://www.mydoc123.com/p-523754.html