ASTM D6843-2002(2007) 752 Standard Test Method for Silanes Used in Rubber Formulations (bis-(triethoxysilylpropyl)sulfanes) Characterization by Gas Chromatography (GC).pdf
《ASTM D6843-2002(2007) 752 Standard Test Method for Silanes Used in Rubber Formulations (bis-(triethoxysilylpropyl)sulfanes) Characterization by Gas Chromatography (GC).pdf》由会员分享,可在线阅读,更多相关《ASTM D6843-2002(2007) 752 Standard Test Method for Silanes Used in Rubber Formulations (bis-(triethoxysilylpropyl)sulfanes) Characterization by Gas Chromatography (GC).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6843 02 (Reapproved 2007)Standard Test Method forSilanes Used in Rubber Formulations(bis-(triethoxysilylpropyl)sulfanes): Characterization by GasChromatography (GC)1This standard is issued under the fixed designation D 6843; the number immediately following the designation indicates t
2、he year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the characterization of
3、silanesof the type bis-(triethoxysilylpropyl)sulfanes by gas chroma-tography.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with i
4、ts use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 4626 Practice for Calculation of Gas ChromatographicResponse Factors
5、E 355 Practice for Gas Chromatography Terms and Rela-tionships3. Terminology3.1 Definitions:3.1.1 PTESPropyltriethoxysilane CH3CH2CH2Si(OEt)33.1.2 Cl-PTESChloropropyltriethoxysilane Cl-CH2CH2CH2Si(OEt)34. Summary of Test Method4.1 In this test method, a sample of the silane is analyzed bygas chromat
6、ography in order to determine the amount ofvolatile components. From the peak areas in the chromato-gram, the percents by weight of volatiles are totaled anddesignated as the total volatile impurities or volatile by-products.5. Significance and Use5.1 The amount of volatile components reflects the i
7、mpuritylevel in the product, and as a consequence, its behavior in arubber mixture.6. Apparatus6.1 Gas Chromatograph, equipped with:6.1.1 Flame Ionization Detector (FID).6.1.2 Capillary Column, typical is 30 m length, 0.25 to 0.53mm internal diameter, fused silica, 0.1 to 1.0 m film thickness.6.1.3
8、Carrier Gas Flow Control, with splitter.6.1.4 Temperature Controls, for injector, detector and col-umn.6.2 Syringe,1mm3(L).6.3 Analytical Balance, accuracy 60.1 mg.6.4 Automatic Pipets, 0.2 to 1.0 cm3,5cm3.6.5 Sample Vials, approximately 15 cm3.7. Reagents7.1 Methanol, analytical grade (for cleaning
9、 syringe).7.2 Undecane,3analytical grade (used as internal standard).7.3 Optional: Cyclohexane, analytical grade (used to dilutethe sample).7.4 Helium, minimum 99.99 % purity, suitable for chro-matographic use, dried (carrier gas).7.5 Hydrogen Gas, minimum 99.99 % purity, total hydro-carbons #1 ppm
10、(for detector).7.6 Air, suitable for chromatographic use, total hydrocar-bons #2 ppm, moisture #3 ppm (for detector).1This test method is under the jurisdiction of ASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.20 on Compounding Materialsand Procedures.Current editi
11、on approved Nov. 1, 2007. Published January 2008. Originallyapproved in 2002. Last previous edition approved in 2002 as D 6843 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informat
12、ion, refer to the standards Document Summary page onthe ASTM website.3Similar hydrocarbons like decane, analytical grade, can be used in place ofundecane, as long as they do not interfere with peaks from the sample.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,
13、 PA 19428-2959, United States.8. Procedure8.1 Set up the gas chromatograph using the followingexample parameters as a guide:Carrier gas He, linear velocity 20 to 50 cm/sSplit ratio 1:4 to 1:10Injectortemperature 250COventemperature Temperature program: for example,50C / 2 min6.5C/min260C / 15 minNot
14、eThe above parameters can be adjustedas appropriate to match the column characteristics.For example, a more narrow column can use a fasterprogram (such as 50C for 1 min. hold/15C/min.ramp/300C for 15 min hold).Detectortemperature 320CCombustion gassesH2, air as needed for FID8.2 Tare a sample vial (
15、W1).8.3 Weigh 5 cm3of Bis-(triethoxysilylpropyl)sulfanes intothe tared sample vial (W2).8.4 Add 1 cm3undecane3(internal standard) and weighagain (W3).8.5 Homogenize the solution by shaking gently.NOTE 1Before injection, the sample may be diluted 1:5 with cyclo-hexane.8.6 Inject 0.5 mm3(L) of the nea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD684320022007752STANDARDTESTMETHODFORSILANESUSEDINRUBBERFORMULATIONSBISTRIETHOXYSILYLPROPYLSULFANESCHARACTERIZATIONBYGASCHROMATOGRAPHYGCPDF

链接地址:http://www.mydoc123.com/p-523752.html