1、Designation: D6790/D6790M 16Standard Test Method forDetermining Poissons Ratio of Honeycomb Cores1This standard is issued under the fixed designation D6790/D6790M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the sand-wich honeycomb core Poissons ratio from the anticlasticcurvature radii,
3、 see Fig. 1.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conf
4、ormancewith the standard.1.2.1 Within the text, the inch-pound units are shown inbrackets.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practic
5、es and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C271/C271M Test Method for Density of Sandwich CoreMaterialsD883 Terminology Relating to PlasticsD3878 Terminology for Composite MaterialsD5229/D5229M Test Method for MoistureAbsorpt
6、ion Prop-erties and Equilibrium Conditioning of Polymer MatrixComposite MaterialsE122 Practice for Calculating Sample Size to Estimate, WithSpecified Precision, the Average for a Characteristic of aLot or ProcessE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE456 Terminolog
7、y Relating to Quality and Statistics3. Terminology3.1 DefinitionsTerminology D3878 defines terms relatingto high-modulus fibers and their composites, as well as termsrelating to sandwich constructions. Terminology D883 definesterms relating to plastics. Terminology E456 and Practice E177define terms
8、 relating to statistics. In the event of a conflictbetween terms, Terminology D3878 shall have precedenceover the other terminologies.3.2 Symbols: c = chord measurementCV = coefficient of variation statistic of a sample populationfor a given property (in percent)d = depth measurementRa= anticlastic
9、curvature radiusRc= cylinder radiusSn-1= standard deviation statistic of a sample population fora given propertyx1= test result for an individual specimen from the samplepopulation for a given propertyx = mean or average (estimate of mean) of a sample popu-lation for a given propertyv = Poissons rat
10、io4. Summary of Test Method4.1 This test method determines the Poissons ratio ofsandwich honeycomb core by bending the core around acylinder and taking measurements of the anticlastic curvaturethat occurs.5. Significance and Use5.1 Certain sandwich panel analyses require the Poissonsratio of the hon
11、eycomb core. It is not possible to measure thehoneycombs Poissons ratio by conventional methods.5.2 This test method provides a standard method of deter-mining the Poissons ratio of honeycomb core materials fordesign properties, material specifications, research and devel-opment applications, and qu
12、ality assurance.5.3 Factors that influence the Poissons ratio of honeycombcore materials and shall therefore be reported include thefollowing: core material, methods of material fabrication, coregeometry, core thickness, core thickness uniformity, cell wallthickness, specimen geometry, specimen prep
13、aration, andspecimen conditioning.1This test method is under the jurisdiction of ASTM Committee D30 onComposite Materials and is the direct responsibility of Subcommittee D30.09 onSandwich Construction.Current edition approved April 1, 2016. Published April 2016. Originallyapproved in 2002. Last pre
14、vious edition approved in 2014 as D6790 - 14. DOI:10.1520/D6790_D6790M-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
15、ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Interferences6.1 The test method described here is one means of obtain-ing the Poissons ratio of honeycomb core. However, this testmethod has not been widely used, and it
16、 is in its conceptualstage.6.2 Material and Specimen PreparationPoor material fab-rication practices and damage induced by improper specimenmachining are known causes of high data scatter for sandwichcores. Important aspects of sandwich core specimen prepara-tion that contribute to data scatter incl
17、ude the existence ofjoints, voids or other core discontinuities, out-of-planecurvature, and surface roughness. Non-uniform edge geometrycan influence the measurement of the chord distance describedin 11.6.6.3 Core GeometryCore-specific geometric factors thataffect Poissons ratio include core cell si
18、ze, uniformity of corecell geometry, core cell wall thickness, core cell wall thicknessuniformity, core thickness, and core thickness uniformity.6.4 EnvironmentResults are affected by the environmentalconditions under which specimens are conditioned, as well asthe conditions under which the core is
19、tested. Specimens testedin various environments can exhibit differences in Poissonsratio.6.5 Specimen-Cylinder ContactResults may vary if thespecimen is too rigid in bending to permit intimate contact ofits surface with the cylinder along the specimen center linewithout fracturing the core. Use of a
20、 larger cylinder radius isrecommended if the midpoints of two parallel ends of the corespecimen cannot be made to contact the standard cylinderusing light hand pressure.6.6 Measurement DevicesMeasurements for anticlasticcurvature depth described in 11.6 may be affected by the widthof the scale descr
21、ibed in 7.3 where it contacts the specimen.7. Apparatus7.1 Micrometers and Calipers-Amicrometer having a flatanvil interface, or a caliper of suitable size, shall be used. Theaccuracy of the instrument(s) shall be suitable for reading towithin 0.5 % of the sample length, width and thickness. Fortypi
22、cal specimen geometries, an instrument with an accuracyof 60.025 mm 60.001 in. is desirable for thicknessmeasurement, whereas an instrument with an accuracy of60.25 mm 60.01 in. is desirable for length and widthmeasurement.7.2 CylindersA cylinder shall be utilized to bend the coreto a defined radius
23、 of curvature. Standard tests shall utilize acylinder of 305 mm 12 in. radius. This radius is generallyacceptable for testing of cores up to 25 mm 1.0 in. inthickness. A larger cylinder radius shall be used if the mid-points of two parallel ends of the core specimen cannot bemade to contact the stan
24、dard cylinder using light hand pressurewithout fracturing the core. Tests conducted using non-standard cylinder radii must be designated as such, with thecylinder radius reported with any test results.7.3 ScaleA scale is required that is capable of measuringlength with an accuracy of 61mm60.05 in.7.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6790D6790M20164616STANDARDTESTMETHODFORDETERMININGPOISSONSRATIOOFHONEYCOMBCORES 测定 蜂窝 泊松比 标准 试验

链接地址:http://www.mydoc123.com/p-523583.html