ASTM D6725-2004(2010) 7500 Standard Practice for Direct Push Installation of Prepacked Screen Monitoring Wells in Unconsolidated Aquifers《未固结含水土层里预制的滤网式监测井的直推式安装的标准实施规程》.pdf
《ASTM D6725-2004(2010) 7500 Standard Practice for Direct Push Installation of Prepacked Screen Monitoring Wells in Unconsolidated Aquifers《未固结含水土层里预制的滤网式监测井的直推式安装的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6725-2004(2010) 7500 Standard Practice for Direct Push Installation of Prepacked Screen Monitoring Wells in Unconsolidated Aquifers《未固结含水土层里预制的滤网式监测井的直推式安装的标准实施规程》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6725 04 (Reapproved 2010)Standard Practice forDirect Push Installation of Prepacked Screen MonitoringWells in Unconsolidated Aquifers1This standard is issued under the fixed designation D6725; the number immediately following the designation indicates the year oforiginal adoption or, i
2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is based on recognized methods by whichdirect push monitoring wells
3、may be designed and installed forthe purpose of detecting the presence or absence of a contami-nant, and collecting representative ground water quality data.The design standards and installation procedures herein areapplicable to both detection and assessment monitoring pro-grams for facilities.1.2
4、The recommended monitoring well design, as presentedin this practice, is based on the assumption that the objective ofthe program is to obtain representative ground water informa-tion and water quality samples from aquifers. Monitoring wellsconstructed following this practice should produce relative
5、lyturbidity-free samples for granular aquifer materials rangingfrom gravels to silty sand. Strata having grain sizes smallerthan the recommended design for the smallest diameter filterpack materials should be monitored by alternative monitoringwell designs which are not addressed in this practice.1.
6、3 Direct push procedures are not applicable for monitor-ing well installation under all geologic and soil conditions (forexample, installation in bedrock). Other rotary drilling proce-dures are available for penetration of these consolidatedmaterials for well construction purposes (Guide D5092). Ad-
7、ditionally, under some geologic conditions it may be appropri-ate to install monitoring wells without a filter pack (EPA1991).Guide D6724 may be referred to for additional information onthese and other methods for the direct push installation ofground water monitoring wells.1.4 The values stated in
8、inch-pound units are to be regardedas standard. The values in parentheses are for information only.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and healt
9、h practices and determine the applica-bility of regulatory limitations prior to use.1.6 This practice offers a set of instructions for performingone or more specific operations. This document cannot replaceeducation or experience and should be used in conjunctionwith professional judgement. Not all
10、aspects of this practicemay be applicable in all circumstances. This ASTM standard isnot intended to represent or replace the standard of care bywhich the adequacy of a given professional service must bejudged, nor should this document be applied without consid-eration of the projects many unique as
11、pects. The word“Standard” in the title of this document means only that thedocument has been approved through the ASTM consensusprocess.2. Referenced Documents2.1 ASTM Standards:2D1452 Practice for Soil Exploration and Sampling byAugerBoringsD1587 Practice for Thin-Walled Tube Sampling of Soils forG
12、eotechnical PurposesD2488 Practice for Description and Identification of Soils(Visual-Manual Procedure)D3694 Practices for Preparation of Sample Containers andfor Preservation of Organic ConstituentsD4043 Guide for Selection of Aquifer Test Method inDetermining Hydraulic Properties by Well Technique
13、sD4044 Test Method for (Field Procedure) for InstantaneousChange in Head (Slug) Tests for Determining HydraulicProperties of AquifersD4104 Test Method (Analytical Procedure) for DeterminingTransmissivity of Nonleaky Confined Aquifers by Over-damped Well Response to Instantaneous Change in Head(Slug
14、Tests)D4448 Guide for Sampling Ground-Water MonitoringWellsD4700 Guide for Soil Sampling from the Vadose ZoneD5088 Practice for Decontamination of Field EquipmentUsed at Waste SitesD5092 Practice for Design and Installation of GroundWaterMonitoring WellsD5314 Guide for Soil Gas Monitoring in the Vad
15、ose Zone1This practice is under the jurisdiction of ASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.21 on Ground Water andVadose Zone Investigations.Current edition approved July 1, 2010. Published September 2010. Originallyapproved in 2001. Last previous edit
16、ion approved in 2004 as D672504. DOI:10.1520/D6725-04R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Cop
17、yright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.D5521 Guide for Development of Ground-Water Monitor-ing Wells in Granular AquifersD5778 Test Method for Electronic Friction Cone and Piezo-cone Penetration Testing of SoilsD5781 Guide for U
18、se of Dual-Wall Reverse-CirculationDrilling for Geoenvironmental Exploration and the Instal-lation of Subsurface Water-Quality Monitoring DevicesD5782 Guide for Use of Direct Air-Rotary Drilling forGeoenvironmental Exploration and the Installation ofSubsurface Water-Quality Monitoring DevicesD5783 G
19、uide for Use of Direct Rotary Drilling with Water-Based Drilling Fluid for Geoenvironmental Explorationand the Installation of Subsurface Water-Quality Monitor-ing DevicesD5784 Guide for Use of Hollow-Stem Augers for Geoen-vironmental Exploration and the Installation of SubsurfaceWater-Quality Monit
20、oring DevicesD5785 Test Method for (Analytical Procedure) for Deter-mining Transmissivity of Confined Nonleaky Aquifers byUnderdamped Well Response to Instantaneous Change inHead (Slug Test)D5786 Practice for (Field Procedure) for Constant Draw-down Tests in Flowing Wells for Determining HydraulicPr
21、operties of Aquifer SystemsD5787 Practice for Monitoring Well ProtectionD5881 Test Method for (Analytical Procedure) DeterminingTransmissivity of Confined Nonleaky Aquifers by Criti-cally Damped Well Response to Instantaneous Change inHead (Slug)D5912 Test Method for (Analytical Procedure) Determini
22、ngHydraulic Conductivity of an Unconfined Aquifer byOverdamped Well Response to Instantaneous Change inHead (Slug)D6001 Guide for Direct-Push Ground Water Sampling forEnvironmental Site CharacterizationD6282 Guide for Direct Push Soil Sampling for Environ-mental Site CharacterizationsD6285 Guide for
23、 Locating Abandoned WellsD6634 Guide for the Selection of Purging and SamplingDevices for Ground-Water Monitoring WellsD6724 Guide for Installation of Direct Push Ground WaterMonitoring WellsD6771 Practice for Low-Flow Purging and Sampling forWells and Devices Used for Ground-Water Quality Inves-tig
24、ations3. Terminology3.1 DefinitionsRefer to Terminology D653 for definitionsof terminology.3.2 Definitions of Terms Specific to This Standard:3.2.1 prepacked screena manufactured well screen that isassembled with a slotted inner casing and an external filtermedia support. The external filter media s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6725200420107500STANDARDPRACTICEFORDIRECTPUSHINSTALLATIONOFPREPACKEDSCREENMONITORINGWELLSINUNCONSOLIDATEDAQUIFERS

链接地址:http://www.mydoc123.com/p-523359.html