ASTM D6708-2015 4573 Standard Practice for Statistical Assessment and Improvement of Expected Agreement Between Two Test Methods that Purport to Measure the Same Property of a Mate.pdf
《ASTM D6708-2015 4573 Standard Practice for Statistical Assessment and Improvement of Expected Agreement Between Two Test Methods that Purport to Measure the Same Property of a Mate.pdf》由会员分享,可在线阅读,更多相关《ASTM D6708-2015 4573 Standard Practice for Statistical Assessment and Improvement of Expected Agreement Between Two Test Methods that Purport to Measure the Same Property of a Mate.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6708 15 An American National StandardStandard Practice forStatistical Assessment and Improvement of ExpectedAgreement Between Two Test Methods that Purport toMeasure the Same Property of a Material1This standard is issued under the fixed designation D6708; the number immediately follow
2、ing the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice cov
3、ers statistical methodology for assess-ing the expected agreement between two standard test methodsthat purport to measure the same property of a material, anddeciding if a simple linear bias correction can further improvethe expected agreement. It is intended for use with resultscollected from an i
4、nterlaboratory study meeting the require-ment of Practice D6300 or equivalent (for example, ISO 4259).The interlaboratory study must be conducted on at least tenmaterials that span the intersecting scopes of the test methods,and results must be obtained from at least six laboratories usingeach metho
5、d.1.2 The statistical methodology is based on the premise thata bias correction will not be needed. In the absence of strongstatistical evidence that a bias correction would result in betteragreement between the two methods, a bias correction is notmade. If a bias correction is required, then the pa
6、rsimonyprinciple is followed whereby a simple correction is to befavored over a more complex one.NOTE 1Failure to adhere to the parsimony principle generally resultsin models that are over-fitted and do not perform well in practice.1.3 The bias corrections of this practice are limited to aconstant c
7、orrection, proportional correction or a linear (propor-tional + constant) correction.1.4 The bias-correction methods of this practice are methodsymmetric, in the sense that equivalent corrections are obtainedregardless of which method is bias-corrected to match theother.1.5 A methodology is presente
8、d for establishing the 95 %confidence limit (designated by this practice as the betweenmethods reproducibility) for the difference between two resultswhere each result is obtained by a different operator usingdifferent apparatus and each applying one of the two methodsX and Y on identical material,
9、where one of the methods hasbeen appropriately bias-corrected in accordance with thispractice.NOTE 2In earlier versions of this standard practice, the term “cross-method reproducibility” was used in place of the term “between methodsreproducibility.” The change was made because the “between methodsr
10、eproducibility” term is more intuitive and less confusing. It is importantto note that these two terms are synonymous and interchangeable with oneanother, especially in cases where the “cross-method reproducibility” termwas subsequently referenced by name in methods where a D6708assessment was perfo
11、rmed, before the change in terminology in thisstandard practice was adopted.NOTE 3Users are cautioned against applying the between methodsreproducibility as calculated from this practice to materials that aresignificantly different in composition from those actually studied, as theability of this pr
12、actice to detect and address sample-specific biases (see6.8) is dependent on the materials selected for the interlaboratory study.When sample-specific biases are present, the types and ranges of samplesmay need to be expanded significantly from the minimum of ten asspecified in this practice in orde
13、r to obtain a more comprehensive andreliable 95 % confidence limits for between methods reproducibility thatadequately cover the range of sample specific biases for different types ofmaterials.1.6 This practice is intended for test methods which mea-sure quantitative (numerical) properties of petrol
14、eum or petro-leum products.1.7 The statistical methodology outlined in this practice isalso applicable for assessing the expected agreement betweenany two test methods that purport to measure the same propertyof a material, provided the results are obtained on the samecomparison sample set, the stan
15、dard error associated with eachtest result is known, the sample set design meets the require-ment of this practice, and the statistical degree of freedom ofthe data set exceeds 30.2. Referenced Documents2.1 ASTM Standards:2D5580 Test Method for Determination of Benzene, Toluene,Ethylbenzene, p/m-Xyl
16、ene, o-Xylene, C9and Heavier1This practice is under the jurisdiction of ASTM Committee D02 on PetroleumProducts, Liquid Fuels, and Lubricants and is the direct responsibility of Subcom-mittee D02.94 on Coordinating Subcommittee on Quality Assurance and Statistics.Current edition approved July 1, 201
17、5. Published August 2015. Originallyapproved in 2001. Last previous edition approved in 2013 as D6708 131. DOI:10.1520/D6708-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informatio
18、n, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1Aromatics, and Total Aromatics in Finished Gasoline by
19、Gas ChromatographyD5769 Test Method for Determination of Benzene, Toluene,and Total Aromatics in Finished Gasolines by GasChromatography/Mass SpectrometryD6299 Practice for Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6300
20、 Practice for Determination of Precision and BiasData for Use in Test Methods for Petroleum Products andLubricantsD7372 Guide for Analysis and Interpretation of ProficiencyTest Program Results2.2 ISO Standard:3ISO 4259 Petroleum ProductsDetermination and applica-tion of precision data in relation to
21、 methods of test.3. Terminology3.1 Definitions:3.1.1 between-method bias, na quantitative expression forthe mathematical correction that can statistically improve thedegree of agreement between the expected values of two testmethods which purport to measure the same property.3.1.2 between methods re
22、producibility (RXY), na quantita-tive expression of the random error associated with thedifference between two results obtained by different operatorsusing different apparatus and applying the two methods X andY, respectively, each obtaining a single result on an identicaltest sample, when the metho
23、ds have been assessed and anappropriate bias-correction has been applied in accordancewith this practice; it is defined as the 95 % confidence limit forthe difference between two such single and independentresults.3.1.2.1 DiscussionAstatement of between methods repro-ducibility must include a descri
24、ption of any bias correctionused in accordance with this practice.3.1.2.2 DiscussionBetween methods reproducibility is ameaningful concept only if there are no statistically observablesample-specific relative biases between the two methods, or ifsuch biases vary from one sample to another in such a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD670820154573STANDARDPRACTICEFORSTATISTICALASSESSMENTANDIMPROVEMENTOFEXPECTEDAGREEMENTBETWEENTWOTESTMETHODSTHATPURPORTTOMEASURETHESAMEPROPERTYOFAMATEPDF

链接地址:http://www.mydoc123.com/p-523301.html