1、Designation: D 6564 00 (Reapproved 2005)Standard Guide forField Filtration of Ground-Water Samples1This standard is issued under the fixed designation D 6564; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers methods for field filtration of ground-water samples collected from ground-water monitoring wells,excluding sam
3、ples that contain non-aqueous phase liquids(either Dense Non-Aqueous Phase Liquids (DNAPLs) or LightNon-Aqueous Phase Liquids (LNAPLs). Methods of fieldfiltration described herein could also be applied to samplescollected from wells used for other purposes. Laboratoryfiltration methods are not descr
4、ibed in this guide.1.2 This guide provides procedures available for field filtra-tion of ground-water samples. The need for sample filtrationfor specific analytes should be defined prior to the samplingevent and documented in the site-specific sampling and analy-sis plan in accordance with Guide D 5
5、903. The decision shouldbe made on a parameter-specific basis with consideration of thedata quality objectives of the sampling program, any applicableregulatory agency guidelines, and analytical method require-ments.1.3 This guide offers an organized collection of informationor a series of options a
6、nd does not recommend a specific courseof action. This guide cannot replace education or experienceand should be used in conjunction with professional judgment.Not all aspects of this guide may be applicable in all circum-stances. This guide is not intended to represent or replace thestandard of car
7、e by which the adequacy of a given professionalservice must be judged, nor should this guide be appliedwithout consideration of the many unique aspects of a project.The word “Standard” in the title of this guide means only thatthe guide has been approved through the ASTM consensusprocess.1.4 This st
8、andard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1
9、 ASTM Standards:2D 653 Terminology Relating to Soil, Rock, and ContainedFluidsD 5088 Practice for Decontamination of Field EquipmentUsed at Non-Radioactive Waste SitesD 5092 Practice for Design and Installation of Ground-Water Monitoring Wells in AquifersD 5903 Guide for Planning and Preparing for a
10、 Ground-Water Sampling EventD 6089 Guide for Documenting a Ground-Water SamplingEventF 740 Terminology Relating to Filtration33. Terminology3.1 filter, vto pass a fluid containing particles through afilter medium whereby particles are separated from the fluid.F 7403.2 filter, na device for carrying
11、out filtration whichconsists of the combination of the filter medium and suitablehardware for constraining and supporting it in the path of thefluid. F 7403.3 filter mediumthe permeable material used for a filterthat separates particles from a fluid passing through it. F 7403.4 filter preconditionin
12、gthe process of preparing a filtermedium for filtration3.5 filter systemthe combination of one or more filter withall the associated process hardware required for filtration.F 7403.6 filtratethe fluid that has passed through the filter.F 7403.7 filtrationthe process by which particles are separatedf
13、rom a fluid by passing the fluid through a permeable material.F 7401This guide is under the jurisdiction ofASTM Committee D18 on Soil and Rockand is the direct responsibility of Subcommittee D18.21 on Ground Water andVadose Zone Investigations.Current edition approved Nov. 1, 2005. Published Decembe
14、r 2005. Originallyapproved in 2000. Last previous edition approved in 2000 as D 6564 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summa
15、ry page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.8 filtered samplea ground-water sample which haspassed through a filter medium.3.8.1 DiscussionThis type of sample may also be referredto as a “d
16、issolved” sample. An unfiltered sample containingdissolved, sorbed, coprecipitated and all suspended particlesmay be referred to as a “total” sample.3.9 particlea small discrete mass of solid or liquid matter.F 7404. Significance and Use4.1 A properly designed, installed and developed ground-water m
17、onitoring well, constructed in accordance with PracticeD 5092, should facilitate collection of samples of ground waterthat can be analyzed to determine both the physical andchemical properties of that sample. Samples collected fromthese wells that require analysis for dissolved constituentsshould be
18、 filtered in the field prior to chemical preservation andshipment to the laboratory for analysis.5. Purpose of Ground-Water Sample Filtration5.1 Ground-water samples may be filtered to separate adefined fraction of the sample for analysis.6. Timing of Ground-Water Sample Filtration6.1 Ground-water s
19、amples should be filtered immediatelyupon collection and prior to chemical preservation of thesample. (1)4Filtration should be completed in as short a timeas possible while minimizing sample aeration, agitation, pres-sure changes, temperature changes and prolonged contact withambient air.NOTE 1The p
20、ressure change that occurs when the sample is broughtto the surface may cause changes in sample chemistry which includelosses of dissolved gases and precipitation of dissolved constituents suchas metals. When handling samples during filtration operations, additionalturbulence and mixing of the sampl
21、e with air can cause aeration andoxidation of dissolved ferrous to ferric iron. Ferric iron rapidly precipi-tates as amorphous iron hydroxide and can adsorb other dissolved tracemetals (2).7. Ground-Water Sample Filtration Procedures7.1 Preparation for Ground-Water Sample FiltrationTheground-water s
22、ample filtration process consists of three phases:selection of filtration method; selection and pretreatment offilter media; and ground-water sample filtration prior to trans-fer into the sample container.7.1.1 Filtration Method Selection CriteriaA wide varietyof methods are available for field filt
23、ration of ground-watersamples. In general, filtration equipment can be divided intopositive pressure filtration and vacuum (negative pressure)filtration methods, each with several different filtration mediumconfigurations. Ground-water samples undergo pressurechanges as they are brought from the sat
24、urated zone (whereground water is under pressure greater than atmospheric) to thesurface (where it is under atmospheric pressure), resulting inchanges in sample chemistry. Vacuum filtration methods fur-ther exacerbate pressure changes. For this reason, positivepressure filtration methods are preferr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD656420002005STANDARDGUIDEFORFIELDFILTRATIONOFGROUNDWATERSAMPLES 地下水 样品 现场 过滤 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-522877.html